Question

Why do we want the retention factor in gas chromatography to be no greater than 10

Why do we want the retention factor in gas chromatography to be no greater than 10

Homework Answers

Answer #1

The retention factor is a variable indicating how much time a component spends in the stationary phase compared to a non-retained inert component. So if retention factor is greater than 10 then component spend 10 times more time in stationary phase than mobile phase and chromatography tests are slow and erroneous .

P.S : Please do give a thumbs up since we as an expert take pain and take our time out by typing answer in lucid language and putting best of our knowledge at your doorstep.
Thank you

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
-In gas chromatography, what is retention time? What affect would increasing the column temperature have on...
-In gas chromatography, what is retention time? What affect would increasing the column temperature have on retention time? -Why does the column length affect the ability to separate a mixture of compounds by gas chromatography? -Why is the retention time for solvents like CH2Cl2 and pentane much shorter than the compounds we dissolve in these solvents to analyze using gas chromatography? -A GC sample containing 0.5 mM cyclohexanol was analyzed by gas chromatography to give a peak for cyclohexanol in...
In gas chromatography, (a) why do open tubular columns yield greater solute resolution than packed columns?...
In gas chromatography, (a) why do open tubular columns yield greater solute resolution than packed columns? (Check all that apply.) A.Open tubular columns have greater sample capacity. B.Open tubular columns eliminate the multiple path term (A) from the van Deemter equation. C.Open tubular columns have a lower resistance to gas flow, so longer columns can be used without increasing solute retention times. -why can more rapid flow rates be used with H2 and He carrier gases than with N2, without...
a. In gas chromatography which parameter is changed to alter retention factors of the solutes? b....
a. In gas chromatography which parameter is changed to alter retention factors of the solutes? b. In liquid chromatography which parameter is changed to alter retention factors of the solutes? c. Why does the use of an internal standard with chromatography give more accurate and precise results?
What effect would each of the following have on the retention times in a gas chromatography?...
What effect would each of the following have on the retention times in a gas chromatography? a) increasing the column temperature b) increasing the flow rate of the carrier gas c) increasing the amount of sample injected
For a gas chromatography experiment, the retention time for m-xylene (pure) is 7.294 seconds. If m-xylene...
For a gas chromatography experiment, the retention time for m-xylene (pure) is 7.294 seconds. If m-xylene is placed in a mixture with para xylene and o-xylene, will the retention time for m-xylene change or remain the same?
ORGANIC CHEMISTRY : GAS CHROMATOGRAPHY the retention time of a particular compound depends on the conditions...
ORGANIC CHEMISTRY : GAS CHROMATOGRAPHY the retention time of a particular compound depends on the conditions under which the chromatograph is obtained. therefore, it is important to record those conditions onto the chchromatogram.what four conditions set for the gas chromatography apparatus that you need to record? .also if you are trying to seperate an aldehyde from a ketone,what typ eof stationary phase is likely to work? a polar o rnonpolar stationary phase? explain.
In gas chromatography, what is the effect on retention time (longer, shorter, or unchanged) of the...
In gas chromatography, what is the effect on retention time (longer, shorter, or unchanged) of the following? a. Loss of stationary phase by column bleeding. b. Operating the column at higher temperature. c. Operating the column at a higher head pressure. d. Clipping off 5% of the column to remove non-volatile contaminants. e. Changing the carrier gas from He to N2, if flow, temperature, and the column are the same.
The column of a gas chromatography is polar, and a mixture of a polar compound and...
The column of a gas chromatography is polar, and a mixture of a polar compound and a nonpolar compound is injected. Which of the two compounds will have the higher retention time? Why?
Capacity factor – why it is used instead of retention time
Capacity factor – why it is used instead of retention time
Explain why it is more difficult to couple liquid chromatography with mass spectrometry than it is...
Explain why it is more difficult to couple liquid chromatography with mass spectrometry than it is to couple gas chromatography with mass spectrometry.