Question

The column of a gas chromatography is polar, and a mixture of a polar compound and...

The column of a gas chromatography is polar, and a mixture of a polar compound and a nonpolar compound is injected. Which of the two compounds will have the higher retention time? Why?

Homework Answers

Answer #1

Polar compond have higher retention time.

Explanation -

Column of gas chromatography is polar it is stationary phase. polar molecule intract more than non polar molecule with polar column satationary phase and take more time to elute therefore it retention time is more.

but, non polar molecule donot intract with polar column satationary phase and elute fast with gas mobile phase and take less time to elute.

because of above reson Polar compond have higher retention time.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
the column in a gas chromatograph is polar, and a mixture of a polar compound and...
the column in a gas chromatograph is polar, and a mixture of a polar compound and a non polar compound is injected. which of the two compounds will have the higher retention time? why?
-In gas chromatography, what is retention time? What affect would increasing the column temperature have on...
-In gas chromatography, what is retention time? What affect would increasing the column temperature have on retention time? -Why does the column length affect the ability to separate a mixture of compounds by gas chromatography? -Why is the retention time for solvents like CH2Cl2 and pentane much shorter than the compounds we dissolve in these solvents to analyze using gas chromatography? -A GC sample containing 0.5 mM cyclohexanol was analyzed by gas chromatography to give a peak for cyclohexanol in...
If a GC separation is performed on a nonpolar and slightly more polar column (same length),...
If a GC separation is performed on a nonpolar and slightly more polar column (same length), which of the following sentences is most correct. Please explain your answer. a) On a more polar column, all molecules will have longer retention times. b) On a more polar column, retention times will be unchaged. c) On a more polar column, molecules that are more polar will have longer retention times. d) On a more polar column, nonpolar compounds will have shorter retention...
In a hypothetical column chromatography, the procedure for the separation of a polar and non-polar compound...
In a hypothetical column chromatography, the procedure for the separation of a polar and non-polar compound calls for sequential elution with the following solvents: hexane,70:30 hexane:acetone, acetone, and 80:20 acetone:methanol. Why is it important to follow this solvent order?
Answer the following about chromatography a. A normal phase column chromatography for the separation of a...
Answer the following about chromatography a. A normal phase column chromatography for the separation of a polar and a nonpolar compound calls for a sequential elution of the following two solvents: Methylene chloride & Hexanes Which solvent should be used first? Please explain b. A student loaded a mixture onto a small silica chromatography column in 1 mL of methanol, then proceeded to elute with hexanes/ethyl acetate/methanol gradient. The student found that all of the mixture came off in the...
A nonpolar aromatic compounds were separated by high performance liquid chromatography on an C18 column. If...
A nonpolar aromatic compounds were separated by high performance liquid chromatography on an C18 column. If eluent solution was 50% MeOH in water,  how would the retention times be affected if 90% MeOH in water? ... Octanoic acid and 1-aminooctane were passed through the same column using an eluent of 20% MeOH/80% buffer (pH3.0). Which compound is expected to be eluted first and why? Thanks
ORGANIC CHEMISTRY : GAS CHROMATOGRAPHY the retention time of a particular compound depends on the conditions...
ORGANIC CHEMISTRY : GAS CHROMATOGRAPHY the retention time of a particular compound depends on the conditions under which the chromatograph is obtained. therefore, it is important to record those conditions onto the chchromatogram.what four conditions set for the gas chromatography apparatus that you need to record? .also if you are trying to seperate an aldehyde from a ketone,what typ eof stationary phase is likely to work? a polar o rnonpolar stationary phase? explain.
What effect would each of the following have on the retention times in a gas chromatography?...
What effect would each of the following have on the retention times in a gas chromatography? a) increasing the column temperature b) increasing the flow rate of the carrier gas c) increasing the amount of sample injected
Column Chromatography lab question: If you are doing a column on a mixture and both compounds...
Column Chromatography lab question: If you are doing a column on a mixture and both compounds come off too quickly to separate, what would be a way to solve the problem?
Consider a mixture of benzene (bp 80) and acetone (bp 56). (a) which compound will emerge...
Consider a mixture of benzene (bp 80) and acetone (bp 56). (a) which compound will emerge first on a non-polar column? on a polar column? (b) which type of column (polar or nonpolar) would gie a better separation or resolution of benzene-acetone mixture? Now cosider a mixture of aetone and butanone (bp 79.5) and compare with the benzene-acetone. (c) will the resolution of the acetone-butanone mixture be better or worse than for the acetone-benzene mixture ont he non-polar column? (d)...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT