Question

short procedure of how to isolate pumpking pigment in TLC plate

short procedure of how to isolate pumpking pigment in TLC plate

Homework Answers

Answer #1

Pumpkin pigment is extracted from the flower of the plant. The corolla is used for extraction of carotenoid the pigment. the flower part is grinded, and the pigment is extracted with equivolume mixture of hexane and acetone. Dried with MgSO4. Washed with water and brine. the carotenoid is dried.

TLC silica gel plates can be used with solvent mixture of pet ether and acetone (9:1) ratio. we can use any primary beta carotene for reference. Place two spots on TLC plate. run the plate in the solvent mixture. TLC can be developed in UV chamber. Rf values can be calcualted.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
TLC Lab question: Zeaxanthin is the pigment that gives paprika its characteristic color. Based upon your...
TLC Lab question: Zeaxanthin is the pigment that gives paprika its characteristic color. Based upon your knowledge of the structure of b-carotene, would Zeaxanthin have a higher or lower Rf value compared to b-carotene if a mixture of Zeaxanthin and b-carotene were to be spotted on TLC plate which is then developed in a 60 % acetone in hexane solvent system? (Assume that normal phase thin-layer chromatography is being carried out).
In thin-layer chromatography (TLC), the TLC plate may need to be __________________________ in order to identify...
In thin-layer chromatography (TLC), the TLC plate may need to be __________________________ in order to identify the migration of particular chemicals while in high-performance liquid chromatography (HPLC), the movement of chemicals through the column is usually detected by ___________________________ . In thin-layer chromatography (TLC), the parameter describing the migration of chemicals up the TLC plate is called the ______________________ . In high- performance liquid chromatography, the parameter describing the movement of “peaks” of chemicals through the column is called the...
Suppose a TLC plate runs a mixture of glycerophospholipid, tryacylglycerol (TAG), and fatty acid. Sketch the...
Suppose a TLC plate runs a mixture of glycerophospholipid, tryacylglycerol (TAG), and fatty acid. Sketch the TLC plate after it has been developed, showing the approximate location of each component on the plate. (The TLC plate is Polar)
Based on chromatographic theory (how a TLC plate works) which of the four known analgesics is...
Based on chromatographic theory (how a TLC plate works) which of the four known analgesics is the most polar and which is the least polar? Explain reasoning. Acetominiphen, Aspirin, Caffeine, Naproxen.
A student’s sample provide one spot on the TLC plate at an Rf value of 0.9;...
A student’s sample provide one spot on the TLC plate at an Rf value of 0.9; however, there are three compounds present in the student’s sample. How could the TLC analysis be adjusted to show all three spots?
A TLC is run using 2:1 hexane/ethyl acetate on an alumina plate. There were three spots...
A TLC is run using 2:1 hexane/ethyl acetate on an alumina plate. There were three spots all close to the bottom of the plate with low Rf values. How could the TLC be changed to increase the Rf's of the three spots to get better separation?
Chromograhy 1) Why should a TLC plate be removed from the solvent before the solvent front...
Chromograhy 1) Why should a TLC plate be removed from the solvent before the solvent front reaches the top of the plate? 2) Why should the developing chamber for a TLC plate not be open to the atmosphere?
A student developed a TLC plate by spotting the sample 1 cm from the bottom and...
A student developed a TLC plate by spotting the sample 1 cm from the bottom and allowed the solvent to move up to a point 1 cm from the top. He developed this TLC in 30% ethyl acetate in hexane and got a single spot with Rf value 0.3. If the distance travelled by the solvent front was 8 cm, calculate the distance travelled by the spot. Also, calculate the length of the TLC plate he used to do this...
why isn't the same tube used to spot different samples on the tlc plate?
why isn't the same tube used to spot different samples on the tlc plate?
In TLC, what will happen if the initial spot is very large when preparing a plate?
In TLC, what will happen if the initial spot is very large when preparing a plate?