Question

A two-stage cascade refrigeration system is shown below. The refrigerant is R134a. It consists of two...

A two-stage cascade refrigeration system is shown below. The refrigerant is R134a. It consists of two ideal vapor-compression cycles with heat exchange between the condenser of the lowertemperature cycle and the evaporator of the higher-temperature cycle. The hotter cycle operates between 0.7 MPa and 0.35 MPa, while the cooler cycle operates between 0.35 MPa and 0.12 MPa. If the flow rate in the hotter cycle is 0.5 mol/s, determine the following:

What is the flow rate in the cooler cycle? (b) What is the rate of heat removal from the refrigerated unit? (c) What is the power input needed for the compressors? (d) What is the COP?

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A cooling plant adopted a two-stage cascade refrigeration system to meet the required cooling load. In...
A cooling plant adopted a two-stage cascade refrigeration system to meet the required cooling load. In both upper and lower cycles, the refrigerant leaves condenser as saturated liquid and enters compressor as saturated vapor. The isentropic efficiency of the upper cycle compressor is 80 %, while the lower cycle compressor is 70% efficient. The pressure limits of the upper and lower cycles are 1 MPa and 0.2 MPa with refrigerant-134a, respectively. Heat rejection from the lower cycle to the upper...
An air-conditioning system with R134a as the working fluid operates on an ideal vapor compression refrigeration...
An air-conditioning system with R134a as the working fluid operates on an ideal vapor compression refrigeration cycle. The working pressure of the evaporator and the condenser are 200 kPa and 1.0 MPa, respectively. The refrigerant flow rate is 0.03 kg/s. a) Draw the process cycle on a T-s diagram with labels. b) Determine the power input and COP of the system. c) Determine the tons of refrigeration. d) What is the SEER rating of the system? e) What is the...
Consider a single-stage refrigeration system operating between the pressure limits of 1.4 MPa and 160 kPa...
Consider a single-stage refrigeration system operating between the pressure limits of 1.4 MPa and 160 kPa with refrigerant R134a as the working fluid. The refrigerant is a saturated liquid at the condenser exit and a saturated vapor at the compressor inlet. The isentropic efficiency for the compressor is 80 percent. If the mass flow rate of the refrigerant through the cycle is 0.11 kg/s determine (a) the rate of heat removal from the refrigerated space, and (b) the coefficient of...
Regarding a Vapor-Compression cycle: A refrigerant (HCFC-22) enters the compressor of a refrigerator as a superheated...
Regarding a Vapor-Compression cycle: A refrigerant (HCFC-22) enters the compressor of a refrigerator as a superheated vapor at .14MPa and -20 degrees Celsius at a rate of .05 kg/s and leaves at .8 MPa and 50 degrees Celsius. The refrigerant is cooled in the condenser to 26 degrees Celsius and .72MPa and is then throttled down to .15 MPa. Determine the rate of heat removal from the refrigerated space and the power input to the compressor and the Coefficient of...
Consider a commercial refrigerator which operates on the refrigeration cycle. R- 134a is used as the...
Consider a commercial refrigerator which operates on the refrigeration cycle. R- 134a is used as the working uid and the refrigerated space is kept at -25oC by rejecting its waste heat to cooling water that enters the condenser at room temperature, that is 20oC, at a rate of 0.1 kg/s and leaves at 40oC. The refrigerant enters the condenser at 1.2 MPa and 70oC and leaves at 40oC. The inlet state of the compressor is saturated vapor at 100 kPa...
- a vapour-compression air-conditioning cycle where the compressor has an isentropic efficiency of 75%. Refrigerant (R12)...
- a vapour-compression air-conditioning cycle where the compressor has an isentropic efficiency of 75%. Refrigerant (R12) is used as the working fluid with a mass now rate of 0.04kg/s. saturated vapour eaters the compressor at 0.5 MPa and leaves to the condenser at 1.2IMPa. The air-conditioner cools down the station to 26°C through an evaporator, and rejects heat to the 34°C ambient through a condenser. (a) Sketch and label the schematic of the air-conditioning cycle and its T-S and P-h...
An air conditioner using refrigerant-134a as the working fluid and operating on the ideal vapor-compression refrigeration...
An air conditioner using refrigerant-134a as the working fluid and operating on the ideal vapor-compression refrigeration cycle is to maintain a space at 36°C while operating its condenser at 1600 kPa. Determine the COP of the system when a temperature difference of 4°C is allowed for the transfer of heat in the evaporator. (Take the required values from saturated refrigerant-134a tables.)
An idea vapor-compression refrigeration cycle, with refrigerant R-22 as the working fluid, has an evaporator temperature...
An idea vapor-compression refrigeration cycle, with refrigerant R-22 as the working fluid, has an evaporator temperature of -12 °C and a condenser pressure of 15 bar. Saturated vapor enters the compressor, and saturated liquid exits the condenser. The refrigerating capacity is 4 tons. a.Determine the compressor power (in kW). b.Determine the mass flow rate of the refrigerant (in kg/min). c.Determine the coefficient of performance.
An ideal vapor-compression refrigeration cycle operates at steady state with Refrigerant 134a as the working fluid....
An ideal vapor-compression refrigeration cycle operates at steady state with Refrigerant 134a as the working fluid. Saturated vapor enters the compressor at 1 bar, and saturated liquid exits the condenser at 4 bar. The mass flow rate of refrigerant is 8.5 kg/min. Determine the compressor power, in kW.
A commercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerated space...
A commercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerated space at −30°C by rejecting its waste heat to cooling water that enters the condenser at 18°C at a rate of 0.32 kg/s and leaves at 26°C. The refrigerant enters the condenser at 1.2 MPa and 65°C and leaves at 42°C. The inlet state of the compressor is 60 kPa and −34°C and the compressor is estimated to gain a net heat of 460 W...