Question

A cooling plant adopted a two-stage cascade refrigeration system to meet the required cooling load. In...

A cooling plant adopted a two-stage cascade refrigeration system to meet the required cooling load. In both upper and lower cycles, the refrigerant leaves condenser as saturated liquid and enters compressor as saturated vapor. The isentropic efficiency of the upper cycle compressor is 80 %, while the lower cycle compressor is 70% efficient. The pressure limits of the upper and lower cycles are 1 MPa and 0.2 MPa with refrigerant-134a, respectively. Heat rejection from the lower cycle to the upper cycle takes place in an adiabatic counterflow heat exchanger where the lower cycle enters about at 0.5 MPa and the upper cycle enter about at 0.32MPa. If the mass flow rate of the refrigerant in the upper cycle is 0.28 kg/s, determine
1)the mass flow rate of the refrigerant in the lower cycle
2)the rate of heat removal from the refrigerated space and the power input into the compressors
3)the COP of the refrigerator,

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A two-stage cascade refrigeration system is shown below. The refrigerant is R134a. It consists of two...
A two-stage cascade refrigeration system is shown below. The refrigerant is R134a. It consists of two ideal vapor-compression cycles with heat exchange between the condenser of the lowertemperature cycle and the evaporator of the higher-temperature cycle. The hotter cycle operates between 0.7 MPa and 0.35 MPa, while the cooler cycle operates between 0.35 MPa and 0.12 MPa. If the flow rate in the hotter cycle is 0.5 mol/s, determine the following: What is the flow rate in the cooler cycle?...
Consider a single-stage refrigeration system operating between the pressure limits of 1.4 MPa and 160 kPa...
Consider a single-stage refrigeration system operating between the pressure limits of 1.4 MPa and 160 kPa with refrigerant R134a as the working fluid. The refrigerant is a saturated liquid at the condenser exit and a saturated vapor at the compressor inlet. The isentropic efficiency for the compressor is 80 percent. If the mass flow rate of the refrigerant through the cycle is 0.11 kg/s determine (a) the rate of heat removal from the refrigerated space, and (b) the coefficient of...
Consider a commercial refrigerator which operates on the refrigeration cycle. R- 134a is used as the...
Consider a commercial refrigerator which operates on the refrigeration cycle. R- 134a is used as the working uid and the refrigerated space is kept at -25oC by rejecting its waste heat to cooling water that enters the condenser at room temperature, that is 20oC, at a rate of 0.1 kg/s and leaves at 40oC. The refrigerant enters the condenser at 1.2 MPa and 70oC and leaves at 40oC. The inlet state of the compressor is saturated vapor at 100 kPa...
A commercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerated space...
A commercial refrigerator with refrigerant-134a as the working fluid is used to keep the refrigerated space at −30°C by rejecting its waste heat to cooling water that enters the condenser at 18°C at a rate of 0.32 kg/s and leaves at 26°C. The refrigerant enters the condenser at 1.2 MPa and 65°C and leaves at 42°C. The inlet state of the compressor is 60 kPa and −34°C and the compressor is estimated to gain a net heat of 460 W...
A condenser is essentially a type of heat exchanger that is used to remove heat from...
A condenser is essentially a type of heat exchanger that is used to remove heat from a vapor and convert it to liquid. The picture below shows a condenser that is used in a commercial refrigerator with refrigerant-134a as the working fluid. Water enters the condenser at 18ºC at a rate of 0.25 kg/s and leaves at 26ºC. The refrigerant enters the condenser at 1.2 MPa and 50ºC and leaves at the same pressure but at T=41.3ºC. a) Find the...
A commercial refrigerator with refrigerant R-134a as the working fluid is used to keep the refrigerated...
A commercial refrigerator with refrigerant R-134a as the working fluid is used to keep the refrigerated space at -30 C by rejecting its waste heat to cooling water that enters the condenser at 18 C at a rate of 0.25 kg/s and leaves at 26 C. The refrigerant enters the condenser at 1.2 MPa and 65 C and leaves at 42 C. The inlet state of the compressor is 60 kPa and -34 C and the compressor is estimated to...
R-134a enters the compressor of a refrigerator as superheated vapour at 0.14 MPa, -10 °C at...
R-134a enters the compressor of a refrigerator as superheated vapour at 0.14 MPa, -10 °C at a rate of 0.12 kg/s, and it leaves at 0.7 MPa and 50 °C. The refrigerant is cooled in the condenser to 24 °C and 0.65 MPa, and it is throttled to 0.15 MPa. Disregard any heat transfer and pressure drops in the connecting lines between the components. Show the cycle on a T-s diagram with respect to saturation lines, and determine (a) the...
A vapor-compression refrigeration cycle operates at steady state with Refrigerant 134a as the working fluid. Saturated...
A vapor-compression refrigeration cycle operates at steady state with Refrigerant 134a as the working fluid. Saturated vapor enters the compressor at 2 bar, and saturated liquid exits the condenser at 8 bar. The isentropic compressor efficiency is 80%. The mass flow rate of refrigerant is 7 kg/min. Determine: (a) the compressor power, in kW, (b) the refrigeration capacity, in tons, (1 ton = 3.5168 kW) and, (c) the coefficient of performance, (d) rate of entropy production in kW/K, for the...
An ideal vapor-compression refrigeration cycle operates at steady state with Refrigerant 134a as the working fluid....
An ideal vapor-compression refrigeration cycle operates at steady state with Refrigerant 134a as the working fluid. Saturated vapor enters the compressor at 1 bar, and saturated liquid exits the condenser at 4 bar. The mass flow rate of refrigerant is 8.5 kg/min. Determine the compressor power, in kW.
Regarding a Vapor-Compression cycle: A refrigerant (HCFC-22) enters the compressor of a refrigerator as a superheated...
Regarding a Vapor-Compression cycle: A refrigerant (HCFC-22) enters the compressor of a refrigerator as a superheated vapor at .14MPa and -20 degrees Celsius at a rate of .05 kg/s and leaves at .8 MPa and 50 degrees Celsius. The refrigerant is cooled in the condenser to 26 degrees Celsius and .72MPa and is then throttled down to .15 MPa. Determine the rate of heat removal from the refrigerated space and the power input to the compressor and the Coefficient of...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT