Question

A wye connected three-phase source is delivering a line voltage of 480 V at a line...

A wye connected three-phase source is delivering a line voltage of 480 V at a line current of 25 amperes.

Find

a) the phase voltage

b) the phase current

c) the line voltage

d) the line current

e) the total power delivered.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A balanced wye-connected three-phase source has line-to-neutral voltages of 400 V rms. - Find the rms...
A balanced wye-connected three-phase source has line-to-neutral voltages of 400 V rms. - Find the rms line-to-line voltage magnitude. - If this source is applied to a wye-connected load composed of three 33 Ω resistances, find the rms line-current magnitude. - If this source is applied to a wye-connected load composed of three 33 Ω resistances, find the total power delivered.
The magnitude of the phase voltage of an ideal balanced three-phase Y-connected source is 110 V...
The magnitude of the phase voltage of an ideal balanced three-phase Y-connected source is 110 V . The source is connected to a balanced Y-connected load by a distribution line that has an impedance of 0.1+0.8i Ω/ϕ . The load impedance is 20.2+14.8i Ω/ϕ . The phase sequence of the source is acb. Use the a-phase voltage of the source as the reference. Part A: Specify the magnitude and phase angle of the line current IaA. Part B: Specify the...
A 70.7 (line voltage) three phase star connected source is connected to a balanced delta load...
A 70.7 (line voltage) three phase star connected source is connected to a balanced delta load having impedance of 14.14 + j14.14 ohms for each phase. Assuming abc sequence, find a) Line currents b) Total 3 phase power
Three single phase transformers having a 15:1 ratio are wye-connected to a 2400 V three phase...
Three single phase transformers having a 15:1 ratio are wye-connected to a 2400 V three phase line as a step-down transformer. What is the line voltage of each transformer? What is the secondary voltage of each transformer if they are delta connected to the same line?
A three phase, 200 kW, 2300 V, 50 Hz star (wye) connected non-salient rotor synchronous motor...
A three phase, 200 kW, 2300 V, 50 Hz star (wye) connected non-salient rotor synchronous motor has a synchronous reactance of 11 Ohms per phase. When it draws 175 kW the power angle is 10 electrical degrees. Neglect the ohmic losses. a. Determine the excitation voltage per phase. b. Calculate the supply line current. c. Determine the supply power factor. d. Draw the phasor diagram. e. By what percentage should the field current be changed to minimize the line current.
The line current of a three-phase engine in delta configuration is 25 A, connected to a...
The line current of a three-phase engine in delta configuration is 25 A, connected to a supply network with a line voltage of 240 V and absorbing a power of 15 kW. The efficiency of the engine is 90%. Taking as a reference of line voltages V1= V∠0º, and a direct sequence, find: a) The phasors of the line voltages b) The phasors of the line and phase currents c) The reactive and apparent power d) The mechanical power (at...
A balanced ?-connected load has an impedance of 60+ j45 ? per phase. The load is...
A balanced ?-connected load has an impedance of 60+ j45 ? per phase. The load is fed through a line having an impedance of 0.8+ j0.6 ? per line. The phase voltage at the terminals of the load is ???????? = 480 ?? . The sequence is positive. Use AB v as the reference at the load. The source is required to be calculated for either Wye or Delta connection. a) Draw the 3-phase system b) Draw the a-phase equivalent...
A balanced three-phase Y-? system has Vab = 380 V rms and Z?=? If the line...
A balanced three-phase Y-? system has Vab = 380 V rms and Z?=? If the line impedance per phase is (0.1 + j0.4)? and total complex power delivered to the load (8+7j)KVA a) find line current b) find the voltage load c) find the current load d) find Z? f) simulation for this circuit on the MULTISIM
A Wye-Delta transformer is connected to a 66 kV input three-phase transmission line. Each transformer is...
A Wye-Delta transformer is connected to a 66 kV input three-phase transmission line. Each transformer is rated at 1000 kVA and has a step-down ratio of 8:1. The bank supplies a balance load having a power factor of 0.8 lag with a load current of 70 A. Assume ideal transformer, determine. The primary line and phase voltages The secondary line and phase voltages The secondary line and phase currents The apparent and active power at the load Total kVA capacity...
A three phase Wye-connected 460 v, 4 poles, 60 Hz wound rotor induction motor has the...
A three phase Wye-connected 460 v, 4 poles, 60 Hz wound rotor induction motor has the following parameters: R1=0.3, R2=0.15, X1=0.5, X2=0.2, Xm=14 The total friction, windage, and core loss is constant at 400 w. The motor is working at its rated voltage and drives its load at 1764 rpm. a)Calculate the input current and the input power. b)Calculate the output mechanical power and torque and motor efficiency. c)Calculate the starting current of this motor and compare it with its...