Question

A balanced ?-connected load has an impedance of 60+ j45 ? per phase. The load is...

A balanced ?-connected load has an impedance of 60+ j45 ? per phase. The load is fed through a line having an impedance of 0.8+ j0.6 ? per line. The phase voltage at the terminals of the load is ???????? = 480 ?? . The sequence is positive. Use AB v as the reference at the load. The source is required to be calculated for either Wye or Delta connection. a) Draw the 3-phase system b) Draw the a-phase equivalent circuit c) Calculate the three phase currents of the load d) Calculate the three line currents e) Calculate the three line voltages at the source

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A delta connected balanced load with impedance "20 - j15" is connected to a star connected...
A delta connected balanced load with impedance "20 - j15" is connected to a star connected generator in positive sequence with Van = "107.43 - j312". Calculate phase and line currents and voltages, also draw the configuration described with the voltage and current labels.
A balanced wye-connected three-phase source has line-to-neutral voltages of 400 V rms. - Find the rms...
A balanced wye-connected three-phase source has line-to-neutral voltages of 400 V rms. - Find the rms line-to-line voltage magnitude. - If this source is applied to a wye-connected load composed of three 33 Ω resistances, find the rms line-current magnitude. - If this source is applied to a wye-connected load composed of three 33 Ω resistances, find the total power delivered.
The line current of a three-phase engine in delta configuration is 25 A, connected to a...
The line current of a three-phase engine in delta configuration is 25 A, connected to a supply network with a line voltage of 240 V and absorbing a power of 15 kW. The efficiency of the engine is 90%. Taking as a reference of line voltages V1= V∠0º, and a direct sequence, find: a) The phasors of the line voltages b) The phasors of the line and phase currents c) The reactive and apparent power d) The mechanical power (at...
The magnitude of the phase voltage of an ideal balanced three-phase Y-connected source is 110 V...
The magnitude of the phase voltage of an ideal balanced three-phase Y-connected source is 110 V . The source is connected to a balanced Y-connected load by a distribution line that has an impedance of 0.1+0.8i Ω/ϕ . The load impedance is 20.2+14.8i Ω/ϕ . The phase sequence of the source is acb. Use the a-phase voltage of the source as the reference. Part A: Specify the magnitude and phase angle of the line current IaA. Part B: Specify the...
A Wye-Delta transformer is connected to a 66 kV input three-phase transmission line. Each transformer is...
A Wye-Delta transformer is connected to a 66 kV input three-phase transmission line. Each transformer is rated at 1000 kVA and has a step-down ratio of 8:1. The bank supplies a balance load having a power factor of 0.8 lag with a load current of 70 A. Assume ideal transformer, determine. The primary line and phase voltages The secondary line and phase voltages The secondary line and phase currents The apparent and active power at the load Total kVA capacity...
calculate the line and neutral currents for the following unbalanced wye-connected impedances: Zan = 2 +...
calculate the line and neutral currents for the following unbalanced wye-connected impedances: Zan = 2 + j5 Ω Zbn = 8 + j0 Ω Zcn = 1 - j15 Ω the voltage source is a balanced three-phase system, 208 V line to line. Assume an abc phase sequence and use Van as the reference phasor.
Problem 2. A three phase transformer rated at 5 MVA, 115/13.2 kV has a per phase...
Problem 2. A three phase transformer rated at 5 MVA, 115/13.2 kV has a per phase series impedance of 0.007 + j0.075 per unit (shunt parameters are ignored). The low voltage side is connected to a short distribution line which modeled by a series per phase impedance of 0.02 +j0.1 per unit on the base of 10 MVA. The line supplies a balanced three phase constant impedance load at 4 MVA, 13.2 kV with power factor of 0.85 lagging •...
Three star-connected coils are drawing line current of 30A from a three phase supply. Also, total...
Three star-connected coils are drawing line current of 30A from a three phase supply. Also, total apparent and active powers of 25kVA and 11 kW respectively are absorbed by the coils. By assuming that the each coil is characterized by equal impedance, determine: i. the line and phase voltages ii. the total reactive power (1 mark) iii. the impedance of each coil. c) If the coils in Q2(b) are suddenly reconfigured into delta connection, calculate the new line currents and...
A 100 MVA, 13.2 kV three phase generator (G) having a synchronous reactance of 10% is...
A 100 MVA, 13.2 kV three phase generator (G) having a synchronous reactance of 10% is connected to a three phase Y-Y transformer T1 which feeds a 132 kV 10 miles transmission line having an impedance per phase of 2 + j5 ?/mile. At the receiving end of the transmission line is a Y-Y step down transformer T2. Three loads are connected to the secondary side of the transformer T2. Loads are as follows: Load#1 40 MVA at 0.8 pf...
A wye connected three-phase source is delivering a line voltage of 480 V at a line...
A wye connected three-phase source is delivering a line voltage of 480 V at a line current of 25 amperes. Find a) the phase voltage b) the phase current c) the line voltage d) the line current e) the total power delivered.
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT