Question

A balanced wye-connected three-phase source has line-to-neutral voltages of 400 V rms. - Find the rms...

A balanced wye-connected three-phase source has line-to-neutral voltages of 400 V rms.

- Find the rms line-to-line voltage magnitude.

- If this source is applied to a wye-connected load composed of three 33 Ω resistances, find the rms line-current magnitude.

- If this source is applied to a wye-connected load composed of three 33 Ω resistances, find the total power delivered.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A wye connected three-phase source is delivering a line voltage of 480 V at a line...
A wye connected three-phase source is delivering a line voltage of 480 V at a line current of 25 amperes. Find a) the phase voltage b) the phase current c) the line voltage d) the line current e) the total power delivered.
The magnitude of the phase voltage of an ideal balanced three-phase Y-connected source is 110 V...
The magnitude of the phase voltage of an ideal balanced three-phase Y-connected source is 110 V . The source is connected to a balanced Y-connected load by a distribution line that has an impedance of 0.1+0.8i Ω/ϕ . The load impedance is 20.2+14.8i Ω/ϕ . The phase sequence of the source is acb. Use the a-phase voltage of the source as the reference. Part A: Specify the magnitude and phase angle of the line current IaA. Part B: Specify the...
A balanced three-phase Y-? system has Vab = 380 V rms and Z?=? If the line...
A balanced three-phase Y-? system has Vab = 380 V rms and Z?=? If the line impedance per phase is (0.1 + j0.4)? and total complex power delivered to the load (8+7j)KVA a) find line current b) find the voltage load c) find the current load d) find Z? f) simulation for this circuit on the MULTISIM
calculate the line and neutral currents for the following unbalanced wye-connected impedances: Zan = 2 +...
calculate the line and neutral currents for the following unbalanced wye-connected impedances: Zan = 2 + j5 Ω Zbn = 8 + j0 Ω Zcn = 1 - j15 Ω the voltage source is a balanced three-phase system, 208 V line to line. Assume an abc phase sequence and use Van as the reference phasor.
A balanced Y-connected 50Hz three-phase source has phase voltage ? ?=400V. Each phase of the load...
A balanced Y-connected 50Hz three-phase source has phase voltage ? ?=400V. Each phase of the load consists of a 0.1-farad capacitance series with a 50-Ω Find the line currents, and the line voltages. Assuming that the phase angle of ??? is 5.
A balanced positive-sequence, Y-connected generator has an impedance of 0.3+j0.6 Ω/Φ, the terminal RMS voltage of...
A balanced positive-sequence, Y-connected generator has an impedance of 0.3+j0.6 Ω/Φ, the terminal RMS voltage of the source is 380V. The generator feeds a balanced, three-phase, Δ-connected load having an impedance of 27 + j42 Ω/Φ. The impedance of the line connecting the generator to the load is 0.6+j1.2 Ω/Φ. 1. Calculate the three line currents. 2. Calculate the line voltages at the terminals of the load. 3. Calculate the phase load currents. 4. Calculate the line voltage at the...
A 70.7 (line voltage) three phase star connected source is connected to a balanced delta load...
A 70.7 (line voltage) three phase star connected source is connected to a balanced delta load having impedance of 14.14 + j14.14 ohms for each phase. Assuming abc sequence, find a) Line currents b) Total 3 phase power
A balanced ?-connected load has an impedance of 60+ j45 ? per phase. The load is...
A balanced ?-connected load has an impedance of 60+ j45 ? per phase. The load is fed through a line having an impedance of 0.8+ j0.6 ? per line. The phase voltage at the terminals of the load is ???????? = 480 ?? . The sequence is positive. Use AB v as the reference at the load. The source is required to be calculated for either Wye or Delta connection. a) Draw the 3-phase system b) Draw the a-phase equivalent...
A Wye-Delta transformer is connected to a 66 kV input three-phase transmission line. Each transformer is...
A Wye-Delta transformer is connected to a 66 kV input three-phase transmission line. Each transformer is rated at 1000 kVA and has a step-down ratio of 8:1. The bank supplies a balance load having a power factor of 0.8 lag with a load current of 70 A. Assume ideal transformer, determine. The primary line and phase voltages The secondary line and phase voltages The secondary line and phase currents The apparent and active power at the load Total kVA capacity...
A three phase balanced resistive load has a line voltage VL = 381.05 V and line...
A three phase balanced resistive load has a line voltage VL = 381.05 V and line current IL = 30 A. Calculate 1) the total power taken by the load 2) the power taken by each phase of the load.
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question