A balanced positive-sequence, Y-connected generator has an impedance of 0.3+j0.6 Ω/Φ, the terminal RMS voltage of the source is 380V. The generator feeds a balanced, three-phase, Δ-connected load having an impedance of 27 + j42 Ω/Φ. The impedance of the line connecting the generator to the load is 0.6+j1.2 Ω/Φ.
1. Calculate the three line currents.
2. Calculate the line voltages at the terminals of the load.
3. Calculate the phase load currents.
4. Calculate the line voltage at the source terminals.
5. Calculate the total apparent power supplied by generator.
6. Calculate the total apparent power absorbed by the load.
7. Calculate the total power losses.

Please its a request to answer all parts

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A balanced ?-connected load has an impedance of 60+ j45 ? per phase. The load is...
A balanced ?-connected load has an impedance of 60+ j45 ? per phase. The load is fed through a line having an impedance of 0.8+ j0.6 ? per line. The phase voltage at the terminals of the load is ???????? = 480 ?? . The sequence is positive. Use AB v as the reference at the load. The source is required to be calculated for either Wye or Delta connection. a) Draw the 3-phase system b) Draw the a-phase equivalent...
A balanced wye-connected three-phase source has line-to-neutral voltages of 400 V rms. - Find the rms...
A balanced wye-connected three-phase source has line-to-neutral voltages of 400 V rms. - Find the rms line-to-line voltage magnitude. - If this source is applied to a wye-connected load composed of three 33 Ω resistances, find the rms line-current magnitude. - If this source is applied to a wye-connected load composed of three 33 Ω resistances, find the total power delivered.
A delta connected balanced load with impedance "20 - j15" is connected to a star connected...
A delta connected balanced load with impedance "20 - j15" is connected to a star connected generator in positive sequence with Van = "107.43 - j312". Calculate phase and line currents and voltages, also draw the configuration described with the voltage and current labels.
Problem 3 The Y-Y system in Figure below has a balanced load and a line impedance...
Problem 3 The Y-Y system in Figure below has a balanced load and a line impedance Zline = 3 Ω + j 15 Ω. If the line voltage at the generator is 12 kV and the total power delivered to the load is 900 kW at 60 A, determine each of the following: a) The magnitude of each phase voltage of the generator. b) The magnitude of the line currents. c) The total power delivered by the source d) The...
A 4- pole, 50 Hz, Y-connected, 3-phase generator has a phase voltage of 260 V ∠0°,...
A 4- pole, 50 Hz, Y-connected, 3-phase generator has a phase voltage of 260 V ∠0°, a synchronous reactance of 0.06 Ω, a stator resistance of 0.003 Ω, and Lsf= 0.02 H. The generator is directly connected to a balanced 3-phase load that draws 2 MW at a lagging 0.8 power factor. Sketch the equivalent circuit annotating all the components, currents and voltages on the diagram Calculate the 3-phase apparent power of the load in rectangular form Calculate the generator...
A balanced Y-connected 50Hz three-phase source has phase voltage ? ?=400V. Each phase of the load...
A balanced Y-connected 50Hz three-phase source has phase voltage ? ?=400V. Each phase of the load consists of a 0.1-farad capacitance series with a 50-Ω Find the line currents, and the line voltages. Assuming that the phase angle of ??? is 5.
A 70.7 (line voltage) three phase star connected source is connected to a balanced delta load...
A 70.7 (line voltage) three phase star connected source is connected to a balanced delta load having impedance of 14.14 + j14.14 ohms for each phase. Assuming abc sequence, find a) Line currents b) Total 3 phase power
A balanced Δ-connected load has an impedance of 216−j288Ω/ϕ. The load is fed through a line...
A balanced Δ-connected load has an impedance of 216−j288Ω/ϕ. The load is fed through a line having an impedance of 3+j5Ω/ϕ. The phase voltage at the terminals of the load is 6.0 kV . The phase sequence is negative. Use VAB as the reference. Part A: Calculate the phase current IAB of the load. Part B: Calculate the phase current IBC of the load. Part C: Calculate the phase current ICA of the load Part D: Calculate the line current...
The magnitude of the phase voltage of an ideal balanced three-phase Y-connected source is 110 V...
The magnitude of the phase voltage of an ideal balanced three-phase Y-connected source is 110 V . The source is connected to a balanced Y-connected load by a distribution line that has an impedance of 0.1+0.8i Ω/ϕ . The load impedance is 20.2+14.8i Ω/ϕ . The phase sequence of the source is acb. Use the a-phase voltage of the source as the reference. Part A: Specify the magnitude and phase angle of the line current IaA. Part B: Specify the...
A balanced three-phase Y-? system has Vab = 380 V rms and Z?=? If the line...
A balanced three-phase Y-? system has Vab = 380 V rms and Z?=? If the line impedance per phase is (0.1 + j0.4)? and total complex power delivered to the load (8+7j)KVA a) find line current b) find the voltage load c) find the current load d) find Z? f) simulation for this circuit on the MULTISIM