Question

A balanced Δ-connected load has an impedance of 216−j288Ω/ϕ. The load is fed through a line...

A balanced Δ-connected load has an impedance of 216−j288Ω/ϕ. The load is fed through a line having an impedance of 3+j5Ω/ϕ. The phase voltage at the terminals of the load is 6.0 kV . The phase sequence is negative. Use VAB as the reference.

Part A: Calculate the phase current IAB of the load.

Part B: Calculate the phase current IBC of the load.

Part C: Calculate the phase current ICA of the load

Part D: Calculate the line current IaA.

Part E: Calculate the line current IbB.

Part F: Calculate the line current IcC.

Part G: Calculate the line voltage Vab at the sending end of the line.

Part H: Calculate the line voltage Vbc at the sending end of the line.

Part I: Calculate the line voltage Vca at the sending end of the line.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
The magnitude of the phase voltage of an ideal balanced three-phase Y-connected source is 110 V...
The magnitude of the phase voltage of an ideal balanced three-phase Y-connected source is 110 V . The source is connected to a balanced Y-connected load by a distribution line that has an impedance of 0.1+0.8i Ω/ϕ . The load impedance is 20.2+14.8i Ω/ϕ . The phase sequence of the source is acb. Use the a-phase voltage of the source as the reference. Part A: Specify the magnitude and phase angle of the line current IaA. Part B: Specify the...
A balanced ?-connected load has an impedance of 60+ j45 ? per phase. The load is...
A balanced ?-connected load has an impedance of 60+ j45 ? per phase. The load is fed through a line having an impedance of 0.8+ j0.6 ? per line. The phase voltage at the terminals of the load is ???????? = 480 ?? . The sequence is positive. Use AB v as the reference at the load. The source is required to be calculated for either Wye or Delta connection. a) Draw the 3-phase system b) Draw the a-phase equivalent...
The time-domain expressions for three line-to-neutral voltages at the terminals of a Y-connected load are vAN=276cos(?t?45?)V,...
The time-domain expressions for three line-to-neutral voltages at the terminals of a Y-connected load are vAN=276cos(?t?45?)V, vBN=276cos(?t?165?)V, vCN=276cos(?t+75?)V. Part A What are the time-domain expressions for the line-to-line voltage vAB? Suppose that vAB(t)=VABcos(?t+?AB), where ?180?<?AB?180?. Determine the values VAB and ?AB. Express your answers using three significant figures separated b What are the time-domain expressions for the line-to-line voltage vBC? Suppose that vBC(t)=VBCcos(?t+?BC), where ?180?<?BC?180?. Determine the values VBC and ?BC. What are the time-domain expressions for the line-to-line voltage...
A balanced positive-sequence, Y-connected generator has an impedance of 0.3+j0.6 Ω/Φ, the terminal RMS voltage of...
A balanced positive-sequence, Y-connected generator has an impedance of 0.3+j0.6 Ω/Φ, the terminal RMS voltage of the source is 380V. The generator feeds a balanced, three-phase, Δ-connected load having an impedance of 27 + j42 Ω/Φ. The impedance of the line connecting the generator to the load is 0.6+j1.2 Ω/Φ. 1. Calculate the three line currents. 2. Calculate the line voltages at the terminals of the load. 3. Calculate the phase load currents. 4. Calculate the line voltage at the...
A delta connected balanced load with impedance "20 - j15" is connected to a star connected...
A delta connected balanced load with impedance "20 - j15" is connected to a star connected generator in positive sequence with Van = "107.43 - j312". Calculate phase and line currents and voltages, also draw the configuration described with the voltage and current labels.
A balanced three-phase Y-? system has Vab = 380 V rms and Z?=? If the line...
A balanced three-phase Y-? system has Vab = 380 V rms and Z?=? If the line impedance per phase is (0.1 + j0.4)? and total complex power delivered to the load (8+7j)KVA a) find line current b) find the voltage load c) find the current load d) find Z? f) simulation for this circuit on the MULTISIM
1- 30-kV, three-phase transmission line has a per phase series impedance of z = 0.05+j0.45 ohm...
1- 30-kV, three-phase transmission line has a per phase series impedance of z = 0.05+j0.45 ohm per Km and a per phase shunt admittance of y = j3.4x10-6 siemens per km. The line is 80 km long. Using the nominal π model, determine a The transmission line ABCD constants. b Find the sending end voltage and current, voltage regulation, the sending end power and the transmission efficiency when the line delivers 1. 200 MVA, 0.8 lagging power factor at 220...
Use MATLAB: A three-phase Y-A transformer is rated 225-kV:24-kV, 400 MVA and has a series reactance...
Use MATLAB: A three-phase Y-A transformer is rated 225-kV:24-kV, 400 MVA and has a series reactance of 6.08 Ohms as referred to its high-voltage terminals. The transformer is supplying a load of 375 MVA, with 0.89 power factor lagging at a voltage of 24 kV (line-to-line) on its low-voltage side. It is supplied from a feeder whose impedance is 0.17 + j 2.2 Ohms connected to its high-voltage terminals. The total load in the system remains constant at 375 MVA....
A 70.7 (line voltage) three phase star connected source is connected to a balanced delta load...
A 70.7 (line voltage) three phase star connected source is connected to a balanced delta load having impedance of 14.14 + j14.14 ohms for each phase. Assuming abc sequence, find a) Line currents b) Total 3 phase power
1- A 69-kV, three-phase short transmission line is 16 km long. The line has a per...
1- A 69-kV, three-phase short transmission line is 16 km long. The line has a per phase series impedance of 0.125 + j0.4375 ohm per km. Determine the sending end voltage, voltage regulation, the sending end power, and the transmission efficiency when the line delivers a. 70 MVA, 0.8 lagging power factor at 64 kV b. 120 MW, unity power factor at 64 kV 2-three-phase, completely transposed 345-kV, 200 km line has two 795,000- cmil 26/2 ACSR conductor per bundle...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT