Question

Mindy, a medical device engineer, is designing an apparatus to monitor the breathing of a patient....

Mindy, a medical device engineer, is designing an apparatus to monitor the breathing of a patient. The apparatus consists of a stretchable loop of conductive material wrapped in a small band around the patient's chest. A constant uniform external magnetic field is produced by a nearby solenoid. As the patient inhales, his chest expands, stretching the chest band. The resulting increase in the area of the loop causes an emf to be induced in the loop. By measuring the induced emf, a device user can estimate the patient's breathing rate. Mindy needs the apparatus to be able to detect a change in area as small as 4.50 cm2 occuring over a time period of 1.50 s.

If the minimum emf that can be reliably detected is 3.00×10−4 V, what is the magnitude of the minimum external magnetic field that would be needed from the solenoid? magnitude of minimum external magnetic field: T

Due to practical constraints, the largest magnetic field that the solenoid can actually produce is 2.40×10−3 T. Mindy decides to compensate by using multiple loops of the conductive material in series. How many conductive loops should be in the chest band? minimum number of conductive loops:

Homework Answers

Answer #1

The formula for EMF induced due to a magnetic flux is

where is the number of loops and

Since we are detecting a change in area in a given time and the magnetic field is held constant, we can re-write our equation as

First Case

Here, we have a single loop, and we need to find out the magnitude of the field to be used.

Note that in every calculation, I have used SI units to simplify it.

Putting in our values, we get...

The magnetic field required has a magnitude of one tesla.

Second case

Here, we have a limit on the magnetic field, and we need to find out .

A minimum of loops are required.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Mindy, a medical device engineer, is designing an apparatus to monitor the breathing of a patient....
Mindy, a medical device engineer, is designing an apparatus to monitor the breathing of a patient. The apparatus consists of a stretchable loop of conductive material wrapped in a small band around the patient's chest. A constant uniform external magnetic field is produced by a nearby solenoid. As the patient inhales, his chest expands, stretching the chest band. The resulting increase in the area of the loop causes an emf to be induced in the loop. By measuring the induced...
You are evaluating the feasibility of a device that will monitor the breathing of patients in...
You are evaluating the feasibility of a device that will monitor the breathing of patients in a hospital. The device is an elastic band, containing many loops of a conductive material, that goes around a patient’s torso. As the patient breathes, the size of the band changes. You decide to calculate the number of loops necessary to generate a detectable emf in the band (which must be at least 1 mV). You know that the average value of the Earth’s...
To monitor the breathing of a hospital patient, a thin belt is girded around the patient's...
To monitor the breathing of a hospital patient, a thin belt is girded around the patient's chest as in the figure below. The belt is a 175-turn coil. When the patient inhales, the area encircled by the coil increases by 38.0 cm2. The magnitude of Earth's magnetic field is 50.0 μT and makes an angle of 30.0° with the plane of the coil. Assuming a patient takes 1.90 s to inhale, find the magnitude of the average induced emf in...
To monitor the breathing of a hospital patient, a thin belt is girded around the patient's...
To monitor the breathing of a hospital patient, a thin belt is girded around the patient's chest as in the figure below. The belt is a 165-turn coil. When the patient inhales, the area encircled by the coil increases by 40.0 cm2. The magnitude of Earth's magnetic field is 50.0 µT and makes an angle of 28.0° with the plane of the coil. Assuming a patient takes 1.50 s to inhale, find the magnitude of the average induced emf in...
Abdominal transducer belts are sometimes used in hospitals to monitor the breathing of patients. One particular...
Abdominal transducer belts are sometimes used in hospitals to monitor the breathing of patients. One particular model consists of a 200-turn coil of wire that wraps around a patient's chest. When the patient inhales, the area bounded by the coil increases by 46.0 cm2. The magnitude of the Earth's magnetic field is 50.0 µT and makes an angle of 28.0° with the plane of the coil. If the patient takes 1.81 s to inhale, what is the magnitude of the...
Explain how a patient\'s breathing may be monitored using a loop of wire wrapped around the...
Explain how a patient\'s breathing may be monitored using a loop of wire wrapped around the patient\'s chest, a source of uniform magnetic field (such as a solenoid), and a sensor (either for voltage or current). As the patient\'s expands and contracts with their breathing, would it make more sense for the sensor to pick up dc or ac signals?
Respiratory inductance plethysmography (RIP) is a method of monitoring breathing. Elastic bands with an internal 200-turn...
Respiratory inductance plethysmography (RIP) is a method of monitoring breathing. Elastic bands with an internal 200-turn coil are placed around the rib cage. During inspiration the cross-sectional area of the rib cage and area encircled by the belt increase by 39.0 cm^2. The magnitude of the Earth’s magnetic field is 50.0 mirco T and makes an angle of 28.0 with the plane of the coil. Assuming a patient inspiration takes 1.80 s, find the magnitude of the average induced emf...
3.Explain why if a CD power supply is used, only when the power supply is turned...
3.Explain why if a CD power supply is used, only when the power supply is turned on or of there is an induced current in the second coil (secondary). 4. Explain why when the switch is on, and there is a direct current through the circuit, there is no induced electric current in that coil. Electromagnetic Induction I. Objectives 1.   Verify the Faraday-Lenz‘s Law 2. Perform measurements with a set of coils to understand how a transformer works. II. Theory In...
In magnetic resonance imaging (MRI), a patient lies in a strong 1- to 2-TT magnetic field...
In magnetic resonance imaging (MRI), a patient lies in a strong 1- to 2-TT magnetic field B⃗ B→ oriented parallel to the body. This field is produced by a large superconducting solenoid. The MRI measurements depend on the magnetic dipole moment μ⃗ μ→ of a proton, the nucleus of a hydrogen atom. The proton magnetic dipoles can have only two orientations: either with the field or against the field. The energy needed to reverse this orientation ("flip" the protons) from...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT