Question

To monitor the breathing of a hospital patient, a thin belt is girded around the patient's...

To monitor the breathing of a hospital patient, a thin belt is girded around the patient's chest as in the figure below. The belt is a 175-turn coil. When the patient inhales, the area encircled by the coil increases by 38.0 cm2. The magnitude of Earth's magnetic field is 50.0 μT and makes an angle of 30.0° with the plane of the coil. Assuming a patient takes 1.90 s to inhale, find the magnitude of the average induced emf in the coil during that time.

Homework Answers

Answer #1

P.S: If you are having any doubt, please comment here, I will surely reply you.Please provide your valuable feedback by a thumbsup. Your thumbsup is a result of our efforts. Your LIKES are very important for me so please LIKE….Thanks in advance!
Please like my solution, its my sincere request, I am in really bad situation, your "upvote" helps me a lot.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
To monitor the breathing of a hospital patient, a thin belt is girded around the patient's...
To monitor the breathing of a hospital patient, a thin belt is girded around the patient's chest as in the figure below. The belt is a 165-turn coil. When the patient inhales, the area encircled by the coil increases by 40.0 cm2. The magnitude of Earth's magnetic field is 50.0 µT and makes an angle of 28.0° with the plane of the coil. Assuming a patient takes 1.50 s to inhale, find the magnitude of the average induced emf in...
Abdominal transducer belts are sometimes used in hospitals to monitor the breathing of patients. One particular...
Abdominal transducer belts are sometimes used in hospitals to monitor the breathing of patients. One particular model consists of a 200-turn coil of wire that wraps around a patient's chest. When the patient inhales, the area bounded by the coil increases by 46.0 cm2. The magnitude of the Earth's magnetic field is 50.0 µT and makes an angle of 28.0° with the plane of the coil. If the patient takes 1.81 s to inhale, what is the magnitude of the...
Mindy, a medical device engineer, is designing an apparatus to monitor the breathing of a patient....
Mindy, a medical device engineer, is designing an apparatus to monitor the breathing of a patient. The apparatus consists of a stretchable loop of conductive material wrapped in a small band around the patient's chest. A constant uniform external magnetic field is produced by a nearby solenoid. As the patient inhales, his chest expands, stretching the chest band. The resulting increase in the area of the loop causes an emf to be induced in the loop. By measuring the induced...
Mindy, a medical device engineer, is designing an apparatus to monitor the breathing of a patient....
Mindy, a medical device engineer, is designing an apparatus to monitor the breathing of a patient. The apparatus consists of a stretchable loop of conductive material wrapped in a small band around the patient's chest. A constant uniform external magnetic field is produced by a nearby solenoid. As the patient inhales, his chest expands, stretching the chest band. The resulting increase in the area of the loop causes an emf to be induced in the loop. By measuring the induced...
Respiratory inductance plethysmography (RIP) is a method of monitoring breathing. Elastic bands with an internal 200-turn...
Respiratory inductance plethysmography (RIP) is a method of monitoring breathing. Elastic bands with an internal 200-turn coil are placed around the rib cage. During inspiration the cross-sectional area of the rib cage and area encircled by the belt increase by 39.0 cm^2. The magnitude of the Earth’s magnetic field is 50.0 mirco T and makes an angle of 28.0 with the plane of the coil. Assuming a patient inspiration takes 1.80 s, find the magnitude of the average induced emf...
You are evaluating the feasibility of a device that will monitor the breathing of patients in...
You are evaluating the feasibility of a device that will monitor the breathing of patients in a hospital. The device is an elastic band, containing many loops of a conductive material, that goes around a patient’s torso. As the patient breathes, the size of the band changes. You decide to calculate the number of loops necessary to generate a detectable emf in the band (which must be at least 1 mV). You know that the average value of the Earth’s...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT