Question

A three storey steel column in a building supports roof and floor loads. The story height...

  1. A three storey steel column in a building supports roof and floor loads. The story height H is 3m, the cross sectional area of the column is 10000mm2, and the modulus of elasticity of steel is 200 GPa. The load carried by the column of each floor are as follows, P1 = 30kN, P2 = 30 kN, P3 = 25 kN.
  1. What is the strain energy of the ground floor column?
  2. What is the strain energy of the second floor column?
  3. What is the strain energy of the third floor column?

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
(30 pts) A short reinforced concrete column is subjected to a 1000 kN axial compressive load....
(30 pts) A short reinforced concrete column is subjected to a 1000 kN axial compressive load. The moduli of elasticity of plain concrete and steel are 25 GPa and 207 GPa, respectively, and the cross-sectional area of steel is 2% of that of the reinforced concrete. Considering the column as a structural member made of a composite material and subjected to load parallel to the steel rebars, calculate the following: a. the modulus of elasticity of the reinforced concrete b....
A four storey building has a storey height of 5.0m on the ground floor and 4m...
A four storey building has a storey height of 5.0m on the ground floor and 4m on the other floors. The roof deck has a dead weight of 400kN while the second to fourth floor has a dead weight of 800kN. The building is located at seismic zone 4 under special occupancy category of I=1 Soil test suggest site coefficient S=1.2; A steel moment resisting frames will be used ( Ct=0.085 ; Rw= 12 ). Determine the following : a.)...
A four storey building has a storey height of 5.0m on the ground floor and 4m...
A four storey building has a storey height of 5.0m on the ground floor and 4m on the other floors. The roof deck has a dead weight of 400kN while the second to fourth floor has a dead weight of 800kN. The building is located at seismic zone 4 under special occupancy category of I=1 Soil test suggest site coefficient S=1.2; A steel moment resisting frames will be used ( Ct=0.085 ; Rw= 12 ). Determine the following : a.)...
A 24 in. x 16 in. column on the second floor of a multi-story building is...
A 24 in. x 16 in. column on the second floor of a multi-story building is to be designed to carry a live load of 500,000 lb, and a dead load that is 75 % of the live load (includes self weight). The nominal moment is calculated to be 5,769 kip.in. Use the interaction diagrams with γ = 0.8 to design the column reinforcement for a concrete strength of 4000 psi and a steel strength of 60000 psi. Include the...
During construction, field tests were conducted to assess the suitability of the column to withstand a...
During construction, field tests were conducted to assess the suitability of the column to withstand a safe buckling load of 2.5 kN assuming a factor of safety 4 using two different hollow columns made up of steel and concrete. Both columns have same cross section but varying length and different support conditions. Steel column of length 3 m having external diameter 40 mm was tested with one end fixed and the other end hinged, when subjected to a compressive stress...
1: During construction, field tests were conducted to assess the suitability of the column to withstand...
1: During construction, field tests were conducted to assess the suitability of the column to withstand a safe buckling load of 2.5 kN assuming a factor of safety 4 using two different hollow columns made up of steel and concrete. Both columns have same cross section but varying length and different support conditions. Steel column of length 3 m having external diameter 40 mm was tested with one end fixed and the other end hinged, when subjected to a compressive...