Question

(30 pts) A short reinforced concrete column is subjected to a 1000 kN axial compressive load....

  1. (30 pts) A short reinforced concrete column is subjected to a 1000 kN axial compressive load. The moduli of elasticity of plain concrete and steel are 25 GPa and 207 GPa, respectively, and the cross-sectional area of steel is 2% of that of the reinforced concrete. Considering the column as a structural member made of a composite material and subjected to load parallel to the steel rebars, calculate the following:

a. the modulus of elasticity of the reinforced concrete

b. the load carried by each of the steel and plain concrete

c. the minimum required cross-sectional area of the column given that the allowable compressive stress of plain concrete is 20 MPa and that the allowable compressive stress of plain concrete will be reached before that of steel.

d. Plot the stress-strain behavior for the steel fiber, concrete and composite on the same plot.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A short reinforced concrete column is subjected to a 700 kips axial compressive load. The modulus...
A short reinforced concrete column is subjected to a 700 kips axial compressive load. The modulus of elasticity of plain concrete and steel are 4,500,000 psi and 29,000,000, respectively, and the cross-sectional area of steel is 3.0% of that of the reinforced concrete. Considering the column as a structural member made of a composite material and subjected to load parallel to the steel bars. Calculate the modulus of elasticity of the reinforced concrete, as well as how much load is...
Determine the largest allowable bending moment for a rectangular reinforced concrete beam having the width b...
Determine the largest allowable bending moment for a rectangular reinforced concrete beam having the width b = 200 mm, total height h = 375 mm and the distance from the bottom surface of the beam to the centre line of steel bars = 75 mm. Use the total area of steel As = 1360 mm2, modulus of elasticity of concrete = 30 GPa, modulus of elasticity of steel = 210 GPa, allowable compressive stress for concrete = 15 MPa and...
A column is made of concrete and reinforced with a W-section steel with an area of...
A column is made of concrete and reinforced with a W-section steel with an area of 2000 mm2. The dimension of the column is 300mm x 350mm. The column is subjected to an axial load of 100 kN. What will be the deformed length of the column? Use Es = 200 GPa and Ec = 25 GPa.
A hollow circular steel column 2m long and outer diameter 200 mm carries an axial load...
A hollow circular steel column 2m long and outer diameter 200 mm carries an axial load of 325 kN. If the compressive stress is 150 MPa, lateral strain for external diameter is is 0.000325 and Poisson’s ratio is 0.3, find the minimum wall thickness required for the column. Also calculate the shear modulus for the material of the column. Take E = 210 GPa.   
Select a light W shape for a column subjected to an axial compressive load of 1623kN....
Select a light W shape for a column subjected to an axial compressive load of 1623kN. The unbraced length of column is 5m and the ends are pinned. Use A36 grade steel.
A (65 KN) wheel load is placed on a Portland cement concrete slab that is (0.240...
A (65 KN) wheel load is placed on a Portland cement concrete slab that is (0.240 m) thick. The concrete has a modulus of elasticity of (27 GPa). The modulus of subgrade reaction is (0.3 N/mm3). Calculate Poisson ratio, if the edge stress is (1.715 MPa) due to a wheel load applied on an equivalent circular area whose radius is (16 cm) for above mentioned slab.
A (65 KN) wheel load is placed on a Portland cement concrete slab that is (0.240...
A (65 KN) wheel load is placed on a Portland cement concrete slab that is (0.240 m) thick. The concrete has a modulus of elasticity of (27 GPa). The modulus of subgrade reaction is (0.3 N/mm3). Calculate Poisson ratio, if the edge stress is (1.715 MPa) due to a wheel load applied on an equivalent circular area whose radius is (16 cm) for above mentioned slab.
A reinforced concrete column, 5.0 m high has a cross section of 400 mm x 400...
A reinforced concrete column, 5.0 m high has a cross section of 400 mm x 400 mm. it is reinforced by four steel bars each 20 mm in diameter and carries a load of 1000 kN. Young’s modulus for steel is 200,000 N/mm2 and for concrete is 15,000 N/mm2. Determine the deformation in mm? please show solution
A reinforced concrete square column (0.26m × 0.26m) is supported by a square isolated footing (spread...
A reinforced concrete square column (0.26m × 0.26m) is supported by a square isolated footing (spread footing). The footing is of plain concrete, and concentrically loaded. An engineer has suggested 1.25m × 1.25m footing. First, check the sufficiency of footing dimension. If it is not sufficient, design the footing in accordance with the requirements of ACI 318M-08 and using the following available data: Net allowable soil pressure: net qa = 170 kPa Column loads (unfactored): D = 160 kN L...
For a 8m long column whose cross sectional dimensions are 0.1m x 0.4m, determine the allowable...
For a 8m long column whose cross sectional dimensions are 0.1m x 0.4m, determine the allowable load using a safety factor of 2.5. The column is welded at both ends. Its yield stress is 250 MPa and its modulus of elasticity is 210 GPa. using Euler Formula or J. B. Johnson Formula.