Question

What is the RFM for flux monitoring in generator? And PRMIS, PD ,

What is the RFM for flux monitoring in generator?

And PRMIS, PD ,

Homework Answers

Answer #1

Rotor flux monitoring which can be done using air gap flux probes is an effective method to determine the occurence of turn-to-turn shorts in the rotor winding of generators and synchronous motors so as to aid in maintenance planning, explaining abnormal vibrations etc.

PROMISE distuinguishes sysnchronous and asychronous operation

Partial discharge (PD) is the phenomenon occuring insulation system of the stator of rotating machines, where local electric field stress exceeds the local electrical strength.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Although trough-only monitoring is practical, the potential limitations surrounding the practice suggest that trough monitoring may...
Although trough-only monitoring is practical, the potential limitations surrounding the practice suggest that trough monitoring may be insufficient to guide vancomycin dosing in all patients. AUC/MIC ratio is considered the PK/PD driver of efficacy for vancomycin. However, such approach may not be recommended for all patients. Mention three cases where such approach is not needed.
if the magnetic field produced by the magnets in a generator is constant, does the magnetic...
if the magnetic field produced by the magnets in a generator is constant, does the magnetic flux through the generator coil change when it is turning? Explain.
If a PI and PD controller is used in conjunction with the following transfer functions what...
If a PI and PD controller is used in conjunction with the following transfer functions what will be the resulting type. a) 40/(s(s+1)(s+2)) PI and PD b) 10/((s+3)(s+5)) PI and PD Please explain in details.
An ac generator has a coil with 2500 turns and area 4.2x10-3 m^2 the coil rotates...
An ac generator has a coil with 2500 turns and area 4.2x10-3 m^2 the coil rotates in magnetic field of .1T and generates an emf of 240Vrms what is the max magnetic flux through coil ? What is the frequency of generator ?
An electric generator is designed to produce a maximum emf of 220 V while rotating with...
An electric generator is designed to produce a maximum emf of 220 V while rotating with an angular speed of 3600 rpm. Each coil of the generator has an area of 0.027 m2. a.) If the magnetic field used in the generator has a magnitude of 0.050 T, how many turns of wire are needed? b.) During the rotation of the coils, the magnetic flux through the coils will alternately be increasing and decreasing. (Why?) While the flux is increasing,...
Please be clear in handwriting and concept. Consider a 2.5 MVA, gearless, direct-drive wind turbine generator...
Please be clear in handwriting and concept. Consider a 2.5 MVA, gearless, direct-drive wind turbine generator controlled to rotate at 17 rpm. The generator produces power at 50 Hz. The rotor flux is 537 mWb and there are 750 turns per phase. Specify the number of poles and the resulting open-circuit line voltage of the generator considering the phase windings are connected in a Wye configuration.
. What is the importance of monitoring serum potassium?
. What is the importance of monitoring serum potassium?
what are the benefits of continous monitoring (CM) of controls?
what are the benefits of continous monitoring (CM) of controls?
ITCO251 What is an important issue in fault monitoring?
ITCO251 What is an important issue in fault monitoring?
What means selective ion monitoring? What is it mainly used for?
What means selective ion monitoring? What is it mainly used for?
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT