Question

A single-phase transformer has 2400 turns on the primary and 600 turns on the secondary. Its...

A single-phase transformer has 2400 turns on the primary and 600 turns on the secondary. Its no-load current is 4A at a power factor of 0.25 lagging. Assuming the volt drop in the windings is negligible, calculate the primary current and power factor when the secondary current is 80A at a power factor of 0.8 lagging.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A 20 kVA single phase transformer 4800/480V has primary resistance and reactance of 5Ω and 15Ω...
A 20 kVA single phase transformer 4800/480V has primary resistance and reactance of 5Ω and 15Ω respectively, while the resistance and reactance of secondary winding is 0.1Ω and 0.15 Ω respectively. Calculate: (i) The parameter referred to primary side of transformer and draw the equivalent circuit (ii) The approximate value of secondary voltage at full load power factor of 0.8 lagging if 4.8kV primary supply
An ideal step-down transformer has a primary coil of 370 turns and a secondary coil of...
An ideal step-down transformer has a primary coil of 370 turns and a secondary coil of 25 turns. Its primary coil is plugged into an outlet with 115 V(AC), from which it draws an rms current of 0.69 A. What is the voltage in the secondary coil? Calculate the rms current in the secondary coil. Assuming that the transformer secondary is driving a resistive load, calculate the average power dissipated in the resistor.
a) An ideal step-down transformer has a primary coil of 400 turns and a secondary coil...
a) An ideal step-down transformer has a primary coil of 400 turns and a secondary coil of 14 turns. Its primary coil is plugged into an outlet with 240 V(AC), from which it draws an rms current of 0.35 A. What is the voltage in the secondary coil? b) Calculate the rms current in the secondary coil. c) Assuming that the transformer secondary is driving a resistive load, calculate the average power dissipated in the resistor.
A 525 V to 110 V, 50 Hz, single phase transformer has a no-load current on...
A 525 V to 110 V, 50 Hz, single phase transformer has a no-load current on the HV side, of 0,5 A at a power factor of 0.36 lagging. Answer the following questions regarding this transformer: 3.1 If a load current of 24 A flows on the LV side, at a power factor of 0.8 lagging, find the value of the primary current and the power factor.   State the assumption and sketch the phasor diagram representing this situation.    (10) 3.2...
An ideal transformer has 100 turns on its primary coil and 200 turns on its secondary...
An ideal transformer has 100 turns on its primary coil and 200 turns on its secondary coil. If 120 V at 2.0 A is applied to the primary, (a) What voltage is present in the secondary? (b) What current is present in the secondary? (c) What is the output power? (d) Is this a step-up or step-down transformer? (e) Is the input power the same, larger or smaller than the output power?
An ideal transformer has 150 turns on the primary winding and 600 turns on the secondary....
An ideal transformer has 150 turns on the primary winding and 600 turns on the secondary. If the primary is connected across a 110V generator, what is the output at the secondary? A: 110V B: 220V C: 440V D: 880V Please show work
A transformer has 1600 turns on its secondary and 200 turns on its primary. The primary...
A transformer has 1600 turns on its secondary and 200 turns on its primary. The primary is connected to a 20V ac source. What is the output voltage of the secondary in volts?
An ideal transformer has 6,000 windings in its primary coil and 10,000 windings in its secondary...
An ideal transformer has 6,000 windings in its primary coil and 10,000 windings in its secondary coil. The primary coil is connected to an RMS voltage of 480 volts. The secondary coil is connected to a single 8,000 Ω resistor. What is the current through the primary coil?
The windings of a transformer primary are effectively a solenoid of 600 turns, radius 2.0 cms...
The windings of a transformer primary are effectively a solenoid of 600 turns, radius 2.0 cms and length 6.0 cms. Calculate the percentage drop in magnetic induction at the centre of the solenoid from the familiar approximation, B = μnI, when corrected for the solenoid aspect ratio.
A Wye-Delta transformer is connected to a 66 kV input three-phase transmission line. Each transformer is...
A Wye-Delta transformer is connected to a 66 kV input three-phase transmission line. Each transformer is rated at 1000 kVA and has a step-down ratio of 8:1. The bank supplies a balance load having a power factor of 0.8 lag with a load current of 70 A. Assume ideal transformer, determine. The primary line and phase voltages The secondary line and phase voltages The secondary line and phase currents The apparent and active power at the load Total kVA capacity...