Concrete is required for an interior concrete column in a commercial building in Corvallis, Oregon. A specified compressive strength, f’c , of 4000 psi is required at 28 days using an ASTM C 150 Type I. The design calls for a minimum of 3 in. of concrete cover over the reinforcing steel. The minimum distance between reinforcing bars is 2.5 in. A slump of 4 inches should be the target. No statistical data on previous mixes are available. Follow mixture proportioning according to Portland Cement Association (PCA) - Design and Control of Concrete Mixtures, Kosmatka and Wilson, 2011, 16th Edition.
Materials Available:
ASTM C 150 Type I/II Cement
Relative density of 3.15
Coarse Aggregate: well-graded ¾ in. maximum-size aggregate (MSA), local river gravel
Oven-dry specific gravity: 2.60
Absorption: 1.2%
Oven-dry rodded bulk density: 102.4 lb/ft3
Moisture content of coarse stockpile: 3.0%
Fine Aggregate: well-graded, local natural sand
Oven-dry specific gravity: 2.55
Absorption: 2.0%
Moisture content of fine stockpile: 3.8%
Fineness Modulus: 2.60
Determine: