Question

) The following recipe was determined as part of a concrete mix design: Water-cement ratio:   0.48...

  1. ) The following recipe was determined as part of a concrete mix design:

Water-cement ratio:   0.48

Coarse aggregate:        0.60 ft3 CA (bulk volume, dry-rodded) per ft3 concrete

Water requirement:    9.6 lbs/ft3 (before moisture corrections)

Air content:                5.0% by volume

Assuming that the CA and FA to be used in the mix are both at SSD, the moisture content of the CA is 0.5%, the moisture content of the FA is 2.5%, the specific gravity of the CA and FA particles are both 2.70, the specific gravity of the cement is 3.15, and the bulk density of the CA is 110 lbs/ft3, calculate the following for a 1.0 ft3 batch of concrete (the unit weight of water is 62.4 lbs/ft3):

  1. The required weight of cement in the batch, Wc (lbs)
  2. The weight of coarse aggregate required, WCA (ft3)
  3. The weight of fine aggregate required, WFA (lbs) in the batch

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Calculate the field weights of the ingredients for 0.039 m3 of concrete by using ACI Method...
Calculate the field weights of the ingredients for 0.039 m3 of concrete by using ACI Method of Mix Design. Job specifications dictate the followings:   Cement content: 300 kg/m3 w/c: 0.57 (by weight, from the strength point of view) w/c: 0.53 (by weight, from durability point of view) Fine Aggregate (SSD)/Coarse Aggregate (SSD)=0.45 (by weight) Air Content: 1,30 %   For Fine Aggregate (Crushed): SSD Bulk Specific Gravity: 2.47, Total Moisture: 5,0 % and Absorption Aggregate: 2,7 %.   For Coarse Aggregate (Crushed):...
A concrete mix design requires each cubic yard of concrete to have 1800 lbs dry coarse...
A concrete mix design requires each cubic yard of concrete to have 1800 lbs dry coarse aggregate (density 4400lb/yd3), 615 lbs cement (density 5300lb/yd3), 320 lbs water (density 1680 lb/yd3), and 6% air. The available aggregates are: coarse aggregate with moisture content of 3.0%, absorption = 1.7%, fine aggregate with moisture content of 3.3%, absorption = 1.9%. Calculate a. Required weight of coarse aggregate b. Required weight of fine aggregate (density 4250 lb/yd3) c. Required weight of water
... 00 E H.W 1. Design concrete mix according to ACI with volumetric equation, and calculate...
... 00 E H.W 1. Design concrete mix according to ACI with volumetric equation, and calculate the quantities of concrete ingredients for a slab and 5 bored piles (Show your results in a Table). Average compressive strength required at 28 days = 35 N / mm 'with Slump is (75-100). Dry rodded mass of coarse aggregate is 1600kg / m3. Fineness modulus of fine aggregate is 2.9. the concrete will be exposed to mild waves of freezing and thawing. The...
From a field data,       Required compressive strength of an OPC air entrained concrete column at...
From a field data,       Required compressive strength of an OPC air entrained concrete column at a moderate exposure is 37±3 MPa. Determine the amount of the ingredients in kg, per 1m3 of concrete: (a) water (b) cement (c) percent air content (d) coarse aggregate (No need to adjust moisture for coarse aggregate):         Given, Nominal maximum size of coarse aggregate is 25 mm Bulk OD specific gravity of coarse aggregate is 2.64 Oven dry-rodded density: 1650 kg/m3 Fineness modulus...
Concrete is required for an interior concrete column in a commercial building in Corvallis, Oregon. A...
Concrete is required for an interior concrete column in a commercial building in Corvallis, Oregon. A specified compressive strength, f’c , of 4000 psi is required at 28 days using an ASTM C 150 Type I. The design calls for a minimum of 3 in. of concrete cover over the reinforcing steel. The minimum distance between reinforcing bars is 2.5 in. A slump of 4 inches should be the target. No statistical data on previous mixes are available. Follow mixture...
15% 11. At a construction site the following materials are available : 5 tons of cement,...
15% 11. At a construction site the following materials are available : 5 tons of cement, 8.2 tons of wet (SSW) sand and 16.5 tons of dry gravel, 1.5 tons of water. In the laboratory the surface moisture of sand is determined to be 8%. The absorption capacities are 3% for each aggregate. SSD Bulk specific gravities are 2.60 for sand and 2.65 for gravel. Specific gravity of cement is 3.10. It is required to produce concrete with the following...
Q2)What would be the maximum aggregate size used for the given mixture properties by using ACI...
Q2)What would be the maximum aggregate size used for the given mixture properties by using ACI Method of Mix Design. 28-day specified concrete strength is 3bMpa, standard deviation is choosen as 3.aMpa and it is required that no more than 1 test result in 200 will fall below the specified strength. Project Title:Detoration of wood column of a commercial building Project summary:Wood deterioration at the lower level of a heavy timber column, which supports five floor levels, was remedied by...
A design engineering determined a water-cement ratio of 0.45 based on the required strength of 4200...
A design engineering determined a water-cement ratio of 0.45 based on the required strength of 4200 psi for concrete. However, the engineering was told that the concrete will subjected to chloride, salt water, brackish water. etc. What is the water-cement ratio to be used for the concrete mix?