Question

... 00 E H.W 1. Design concrete mix according to ACI with volumetric equation, and calculate...

... 00 E H.W 1. Design concrete mix according to ACI with volumetric equation, and calculate the quantities of concrete ingredients for a slab and 5 bored piles (Show your results in a Table). Average compressive strength required at 28 days = 35 N / mm 'with Slump is (75-100). Dry rodded mass of coarse aggregate is 1600kg / m3. Fineness modulus of fine aggregate is 2.9. the concrete will be exposed to mild waves of freezing and thawing. The specific gravity of cement, coarse aggregate, fine aggregate is 3.15. 2.6, and 2.64, respectively for uir content concrete (air entrained). Minimum and maximum cement content is 300 kg / m3 and 350 kg / m3 respectively. Absorption of fine aggregate = 2%: Absorption of coarse aggregate = 1.1% Total Moisture content of coarse aggregate = 2.2%: Total Moisture content of fine aggregate = 1.5%. The dimension of slab is (5m "5m" 15cm) and the diameter of pile is 50 cm with length 12 m and if you know that the minimum clear spacing between individual reinforcing bars for the column is 50 mm and the narrowest dimension between sides of forms is 12.5 cm

Homework Answers

Answer #1

Complete solution is given below.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Calculate the field weights of the ingredients for 0.039 m3 of concrete by using ACI Method...
Calculate the field weights of the ingredients for 0.039 m3 of concrete by using ACI Method of Mix Design. Job specifications dictate the followings:   Cement content: 300 kg/m3 w/c: 0.57 (by weight, from the strength point of view) w/c: 0.53 (by weight, from durability point of view) Fine Aggregate (SSD)/Coarse Aggregate (SSD)=0.45 (by weight) Air Content: 1,30 %   For Fine Aggregate (Crushed): SSD Bulk Specific Gravity: 2.47, Total Moisture: 5,0 % and Absorption Aggregate: 2,7 %.   For Coarse Aggregate (Crushed):...
Concrete is required for an interior concrete column in a commercial building in Corvallis, Oregon. A...
Concrete is required for an interior concrete column in a commercial building in Corvallis, Oregon. A specified compressive strength, f’c , of 4000 psi is required at 28 days using an ASTM C 150 Type I. The design calls for a minimum of 3 in. of concrete cover over the reinforcing steel. The minimum distance between reinforcing bars is 2.5 in. A slump of 4 inches should be the target. No statistical data on previous mixes are available. Follow mixture...
A concrete mix design requires each cubic yard of concrete to have 1800 lbs dry coarse...
A concrete mix design requires each cubic yard of concrete to have 1800 lbs dry coarse aggregate (density 4400lb/yd3), 615 lbs cement (density 5300lb/yd3), 320 lbs water (density 1680 lb/yd3), and 6% air. The available aggregates are: coarse aggregate with moisture content of 3.0%, absorption = 1.7%, fine aggregate with moisture content of 3.3%, absorption = 1.9%. Calculate a. Required weight of coarse aggregate b. Required weight of fine aggregate (density 4250 lb/yd3) c. Required weight of water
From a field data,       Required compressive strength of an OPC air entrained concrete column at...
From a field data,       Required compressive strength of an OPC air entrained concrete column at a moderate exposure is 37±3 MPa. Determine the amount of the ingredients in kg, per 1m3 of concrete: (a) water (b) cement (c) percent air content (d) coarse aggregate (No need to adjust moisture for coarse aggregate):         Given, Nominal maximum size of coarse aggregate is 25 mm Bulk OD specific gravity of coarse aggregate is 2.64 Oven dry-rodded density: 1650 kg/m3 Fineness modulus...
) The following recipe was determined as part of a concrete mix design: Water-cement ratio:   0.48...
) The following recipe was determined as part of a concrete mix design: Water-cement ratio:   0.48 Coarse aggregate:        0.60 ft3 CA (bulk volume, dry-rodded) per ft3 concrete Water requirement:    9.6 lbs/ft3 (before moisture corrections) Air content:                5.0% by volume Assuming that the CA and FA to be used in the mix are both at SSD, the moisture content of the CA is 0.5%, the moisture content of the FA is 2.5%, the specific gravity of the CA and FA particles...
Q2)What would be the maximum aggregate size used for the given mixture properties by using ACI...
Q2)What would be the maximum aggregate size used for the given mixture properties by using ACI Method of Mix Design. 28-day specified concrete strength is 3bMpa, standard deviation is choosen as 3.aMpa and it is required that no more than 1 test result in 200 will fall below the specified strength. Project Title:Detoration of wood column of a commercial building Project summary:Wood deterioration at the lower level of a heavy timber column, which supports five floor levels, was remedied by...
Aconcrete mixture for a proposed building work is to be designed. A characteristic compressive strength of...
Aconcrete mixture for a proposed building work is to be designed. A characteristic compressive strength of 25 MPa with 5% defective rate is specified for 28 days. The standard deviation may be taken based on a compressive strength results on specimens less than 20. A slump of 40 mm is required and the maximum w/c ration and the minimum cement content allowed are 0.7 and 200 kg/m3, respectively. The fine aggregate is uncrushed and the percentage passing sieve 600 Micro...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT