Question

why wont Cu react with Ni2+ ? why wont Sn react with Ni2+?

why wont Cu react with Ni2+ ?

why wont Sn react with Ni2+?

Homework Answers

Answer #1

In general, a metal can replace any metal which is lower in the reactivity series and since Cu is placed lower than Ni in reactivity series ..therefore Cu can not replace Ni or can not react as from moving top to bottom in reactivity series the reactivity decreases.

There occur same case as we move down the reactivity series the reactivity decreases and since Sn is placed below Ni in the rreactivity series therefore Sn can not react with Ni due to the low reactivity of Sn

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Copper(I) ions in aqueous solution react with NH3(aq) according to Cu+(aq) + 2NH3 (aq) --> Cu(NH3)2...
Copper(I) ions in aqueous solution react with NH3(aq) according to Cu+(aq) + 2NH3 (aq) --> Cu(NH3)2 Kf = 6.3*10^10 Calculate the solubility (in g
If 14.5 moles of Cu and 44.8 moles of HNO3 are allowed to react, how many...
If 14.5 moles of Cu and 44.8 moles of HNO3 are allowed to react, how many moles of excess reactant will remain if the reaction goes to completion? 3 Cu + 8 HNO3 ? 3Cu(NO3)2 + 2NO + 4H2O
Rank the activity of aluminum with Ca, Cu,  Fe,  Mg,  Sn, Al, and  Zn.   Rank from most reactive to least...
Rank the activity of aluminum with Ca, Cu,  Fe,  Mg,  Sn, Al, and  Zn.   Rank from most reactive to least reactive. To rank items as equivalent, overlap them.
In the galvanic cell Sn(s) | Sn2+(aq) || Cu2+(aq) | Cu(s) the standard potential is 0.48...
In the galvanic cell Sn(s) | Sn2+(aq) || Cu2+(aq) | Cu(s) the standard potential is 0.48 V. Starting with standard concentrations, what are the concentrations of Sn2+ and Cu2+ when the cell has discharged to a potential of 0.45 V?
Al C Cu Fe Mg Pb Sn Zn Ni Al X 1.170 1.997 1.220 0.710 1.534...
Al C Cu Fe Mg Pb Sn Zn Ni Al X 1.170 1.997 1.220 0.710 1.534 1.524 0.897 1.140 C X 0.827 0.050 1.880 0.364 0.354 0.273 2.310 Cu X 0.777 2.707 0.463 0.473 1.100 3.137 Fe X 1.930 0.314 0.304 0.323 2.360 Mg X 2.244 2.234 1.607 0.430 Pb X 0.010 0.637 2.674 Sn X 0.627 2.664 Zn X 2.037 Ni X Data tabulated in Volts (V). Write a balanced redox reaction equation for all the pairs you tested....
A cyanide solution with a volume of 22.00 mL was treated with 25.00 mL of Ni2...
A cyanide solution with a volume of 22.00 mL was treated with 25.00 mL of Ni2 (containing excess Ni^2+) to convert the cyanide into tetracyanonickelate(II) ion: 4 CN- (aq) + Ni^2+ (aq) -> Ni(CN)4 ^2-(aq) The remaining unreacted Ni^2+ was reacted with 9.00 mL of 0.01500 M EDTA^4- (a reagent that forms 1:1 complexes with Ni2+ ion but does not react with Ni(CN)4^2- ). EDTA4- (aq) + Ni2+(aq) -> Ni(EDTA)^2- If 40.25 mL of the same EDTA titrant is needed...
1. Calculate the equilibrium constant, K, for the reaction in the Galvanic Pb-Cu cell. (Report your...
1. Calculate the equilibrium constant, K, for the reaction in the Galvanic Pb-Cu cell. (Report your answer in scientific notation to three significant figures. Use * for the multiplication sign and ^ to designate the exponent.) Cu+ (aq) + Pb (s) → Cu (s) + Pb2+ (aq) Eocell = 0.647 V K = 2. For the reaction Mg (s) + Ni2+ (aq) →→ Mg2+ (aq) + Ni (s),    Eocell = 2.629 V.   Calculate the cell potential at T = 50.0oC...
The following reactions take place in a galvanic cell: (i) Cu2+(aq)+ Ni (s)→ Cu(s) + Ni2+(aq)...
The following reactions take place in a galvanic cell: (i) Cu2+(aq)+ Ni (s)→ Cu(s) + Ni2+(aq) (ii) 2Ag+ (aq) +H2 (g) → 2Ag(s) +2H+ (aq) (iii) Cl2 (g) + Sn2+ (aq) → Sn4+ (aq) + 2Cl- (aq) (a) For each of the above spontaneous cell reactions, write the electrochemical cell using standard cell notation. (b) Use the standard reduction potentials below to evaluate EƟcell for the overall cell reaction taking place in (iii): Cl2(g) + 2e- → 2Cl- (aq) E...
Find the calculated voltages for each cell. Use equation Eo(cell)= E0(cathode) + Eo(anode) Cell 1: Cu/Cu2+...
Find the calculated voltages for each cell. Use equation Eo(cell)= E0(cathode) + Eo(anode) Cell 1: Cu/Cu2+ Zn/Zn2+ Cell 2: Cu/Cu2+ Fe/Fe3+ Cell 3: Cu/Cu2+ Ni/Ni2+ Cell 4: Zn/Zn2+ Fe/Fe3+ Cell 5: Zn/Zn2+ Ni/Ni2+ Cell 6: Ni/Ni2+ Fe/Fe3+ Find the calculated voltage using the equation Eo(Cell)= -(0.0592/n) log (dilute/concentrated) Cell A 0.0100M 1.00M Cell B 0.0100M .100M Cell C 1.00M 0.100M I don't understand anything, please help.
1. Give a rationalization for the stability of Sn(II) and Sn(IV) versus Sn(III). 2. Several exotic...
1. Give a rationalization for the stability of Sn(II) and Sn(IV) versus Sn(III). 2. Several exotic organometallic compounds of Sn(II) have recently been prepared and structurally characterized. What are some of these compounds, and how do they fit in to the general scheme of tin compounds? 3, The direct reaction of the element with R-Cl is of crucial importance to key industries involving the group 14 elements. What are some of these industries, and why is the direct reaction so...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT