Question

When an ion-selective electrode for X was immersed in 0.0240 M XCl, the measured potential was...

When an ion-selective electrode for X was immersed in 0.0240 M XCl, the measured potential was 0.0270 V. What is the concentration of X when the potential is 0.0420 V? Assume that the electrode follows the Nernst equation, the temperature is at 25°C, and that the activity coefficient of X is 1.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
When an ion-selective electrode for X was immersed in 0.0760 M XCl, the measured potential was...
When an ion-selective electrode for X was immersed in 0.0760 M XCl, the measured potential was 0.0380 V. What is the concentration of X when the potential is 0.0530 V? Assume that the electrode follows the Nernst equation, the temperature is at 25°C, and that the activity coefficient of X is 1.
1) Determine the potential of a platinum electrode (vs. SHE) when placed in the following solutions...
1) Determine the potential of a platinum electrode (vs. SHE) when placed in the following solutions at 25°C. A mixture of 0.0141 M potassium permanganate (KMnO4) and 0.0489 M manganese chloride (MnCl2) at pH 3.6 2) When an ion-selective electrode for X was immersed in 0.0500 M XCl, the measured potential was 0.0250 V. What is the concentration of X when the potential is 0.0400 V? Assume that the electrode follows the Nernst equation, the temperature is at 25°C, and...
An ideal Pb2 ion-selective electrode is moved from a 5.59 × 10-5 M PbNO3 solution to...
An ideal Pb2 ion-selective electrode is moved from a 5.59 × 10-5 M PbNO3 solution to a 0.00449 M PbNO3 solution at 25 °C. By how many millivolts will the potential of the ion-selective electrode change when it is moved from the first solution to the second solution?
a) A metal ion buffer was prepared from 0.022 M ML and 0.026 M L, where...
a) A metal ion buffer was prepared from 0.022 M ML and 0.026 M L, where ML is a metal-ligand complex and L is free ligand. M + L equilibrium reaction arrow ML Kf = 3.7 ✕ 108 Calculate the concentration of free metal ion, M, in this buffer. b) By how many volts will the potential of an ideal Mg2+ ion-selective electrode change if the electrode is removed from 2.55 ✕ 10−4M MgCl2 and placed in 2.05 ✕ 10−3M...
[Ion selective electrode] If some of your F- was bound to Ca2+, how would your measured...
[Ion selective electrode] If some of your F- was bound to Ca2+, how would your measured voltage signal change? Background Info (might be useful): For this lab, you will determine the fluoride content in commercial mouthwashes using an ion selective electrode. This lab uses the direct potentiometry method, which assumes that matrix interferences are not a problem for determining the concentration of fluoride in toothpaste. To combat possible matrix problems, the total ionic strength adjustment buffer (TISAB) solution used in...
Calibration data for a bromide ion-selective electrode (ISE) was collected and recorded below. The potential of...
Calibration data for a bromide ion-selective electrode (ISE) was collected and recorded below. The potential of the ISE was measured against a saturated calomel electrode (SCE). All solutions were buffered at a pH of 7.56. A linear calibration curve can be constructed from this data as a plot of potential (in mV) vs. pBr. Determine the slope and y-intercept of such a plot of the calibration data given. [Br-](M) Potential (mV) 0.300 -21.2 0.0300 36.7 0.00300 96.0 0.000300 154.7 0.0000300...
The calcium ion selective electrode (ISE) measures 11.8 mV in a 1 mM Ca2+ solution at...
The calcium ion selective electrode (ISE) measures 11.8 mV in a 1 mM Ca2+ solution at room temperature. Then the ISE is placed in another solution at body temperature and it measures 20 mV. What is the calcium concentration of the new solution? To avoid complicated theory assume that Eo is not Temperature dependent.
Consider an electrochemical cell with a zinc electrode immersed in 1.0 M Zn2+ and a nickel...
Consider an electrochemical cell with a zinc electrode immersed in 1.0 M Zn2+ and a nickel electrode immersed in 0.10 M Ni2+. Calculate the concentration of Ni2+ if the cell is allowed to run to equilibrium at 25 degrees C.
A student measures the potential of a cell made up with 1.0 M CuSO4 in one...
A student measures the potential of a cell made up with 1.0 M CuSO4 in one solution and 1.0 M AgNO3 in the other. There is a Cu electrode in the CuSO4 and a Ag electrode in the AgNO3. A salt bridge connects the 2 half cells. The student finds that the potential, or voltage of the cell, E°cell is 0.45 V and that the Cu electrode is negative. a. At which electrode is the oxidation occurring? ___________ b. Write...
A galvanic cell is constructed with a silver-silver chloride electrode, and a nickel strip immersed in...
A galvanic cell is constructed with a silver-silver chloride electrode, and a nickel strip immersed in a beaker containing 5.56 x 10-2 M solution of NiC12. Determine the balanced cell reaction and calculate the potential of the cell. Enter in volts. (assume a temperature of 25°C) The answer is not .97
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT