30. A 480/240 Volt, Step-down transformer with a primary current
of 200 amperes will have an...
30. A 480/240 Volt, Step-down transformer with a primary current
of 200 amperes will have an approximate secondary current of ______
amperes.
A. 100
B. 200
C. 300
D. 400
31. The inverter output of a stand-alone photovoltaic system
shall be permitted to supply 120 volts to a single-phase, 3-wire
120/240 volt service where there are no _____ on the system.
A. Motors connected
B. Transformers connected
C. Multi-wire branch circuits
D. Appliance branch circuits
32. When a combination transformer...
A 2.2 KVA, 440---220 V, 60 Hz, step-down transformer has the
following parameters: Rp= 3.0 Ω,...
A 2.2 KVA, 440---220 V, 60 Hz, step-down transformer has the
following parameters: Rp= 3.0 Ω, Xp= 4.0 Ω, Rs= 2.5 Ω, Xs= 2.0 Ω,
Rc= 60 KΩ, and Xm = 15 KΩ. The transformer is operating at full
load with a power factor of 0.707 lagging. The magnetizing branch
impedance can be ignored.
a) Draw the transformer’s equivalent T-circuit,
b) Find the equivalent winding impedance referred to the high
side,
c) Calculate the primary and secondary currents,
d) Determine...
A 2.2 KVA, 440---220 V, 60 Hz, step-down transformer has the
following parameters: Rp= 3.0 Ω,...
A 2.2 KVA, 440---220 V, 60 Hz, step-down transformer has the
following parameters: Rp= 3.0 Ω, Xp= 4.0 Ω, Rs= 2.5 Ω, Xs= 2.0 Ω,
Rc= 60 KΩ, and Xm = 15 KΩ. The transformer is operating at full
load with a power factor of 0.707 lagging. The magnetizing branch
impedance can be ignored.
a) Draw the transformer’s equivalent T-circuit,
b) Find the equivalent winding impedance referred to the high
side,
c) Calculate the primary and secondary currents,
d) Determine...
Demand Curve: (100,50), (150, 40), (200, 30), (250, 20),
(300,10)
Supply Curve: (50,20), (100, 30), (150,...
Demand Curve: (100,50), (150, 40), (200, 30), (250, 20),
(300,10)
Supply Curve: (50,20), (100, 30), (150, 40), (200, 50), (250,
60), (300, 70)
18. What is the quantity bought and sold in the market if the
government implements a subsidy of $40/unit?
a) 100 b) 150 c) 200 d) 250
For questions 19 and 20, please use the following information
for the demand curve and supply curve:
QD =1000–2P QS =-200+P
19. What is the quantity bought and sold if...
Project A has a $500 investment and cash inflows of $200, $250
and $300 in years...
Project A has a $500 investment and cash inflows of $200, $250
and $300 in years 1-3. Project B has a $400 investment and cash
inflows of $300, $100 and $200 in years 1-3. Given this
information, calculate its cross-over IRR.
a. 12.46%
b. 11.46%
c. 14.46%
d. 13.46%
e. 10.46%
Plate values of a three-phase transformer are given
below:
1600 kVA, 15 kV / 400 V,...
Plate values of a three-phase transformer are given
below:
1600 kVA, 15 kV / 400 V, 50 Hz, io = 1.2%; ukN = 6%, idle losses
2450 W, rated
copper losses of power 14500 W; Dy5.
a) Calculate primary and secondary line and phase currents.
b) Secondary at 75% load in power factor with 0.85 inductance and
0.85 capacity
calculate the voltage separately. Compare and interpret the
results. capacity