Question

(c) A voltage transformer for use on an 11 kV system has a star connected primary....

(c) A voltage transformer for use on an 11 kV system has a star connected primary. If the turns ratio is 100/1 what will be the residual voltage of the open delta winding?

(d) A 1 A electromagnetic relay has 80 turns on minimum setting. If the settings are from 50% to 200% in 25% steps, calculate the plug bridge turns for each setting. If the relay presents a burden of 3 VA determine the number of turns required if the relay was to operate at 12 V.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
The transformer is protected by a differential relay. The relay is connected to three phase transformer,...
The transformer is protected by a differential relay. The relay is connected to three phase transformer, 50 MVA, 22 kV/33 kV delta – star connection. The relay is connected in delta. The current transformer ratio is 1500/5 Amp at the lower voltage and 1000/5 Amp at the high voltage. Calculate the primary and secondary current of the relay and it’s the primary turns. State any assumption.
A transformer has a primary-to-secondary turns ratio of 100:1. The voltage on the primary side is...
A transformer has a primary-to-secondary turns ratio of 100:1. The voltage on the primary side is 27.7 kv.a.c. at 60.0 Hz ( assume 60.0 Hz when treating electric power topics). A load is connected across the secondary winding. Assume that the transformer is ideal. (a) Suppose that the electric utility supplied 27.7 kv.d.c. rather than 27.7 kv.a.c. How much power would the transformer’s secondary winding deliver to the load in this case? (b). The transformer’s primary winding is supplied by...
2(a). A transformer has a primary-to-secondary turns ratio of 100:1. The voltage on the primary side...
2(a). A transformer has a primary-to-secondary turns ratio of 100:1. The voltage on the primary side is 27.7 kv.a.c. at 60.0 Hz ( assume 60.0 Hz when treating electric power topics). A load is connected across the secondary winding. Assuming that the transformer is ideal, what voltage is developed to the load? Briefly show your work. Sketch a diagram. 2(b). The load of part a is a 2.00-ohm load. How much current does the load draw from the transformer’s secondary...
A)A transformer has a primary with 10 turn and a 120V AC source connected to it....
A)A transformer has a primary with 10 turn and a 120V AC source connected to it. The secondary has 20 turns. Calculate the voltage on the secondary B)A transformer has a primary with 10 turn and a 120V AC source connected to it. The secondary has 20 turns. Calculate the current in the secondary C) A device requires 40W of power to function. Given 120V are applied to the device, calculate the current through the device. D)Calculate the rate of...
A transformer has 380 primary turns and 1140 secondary turns. The input voltage is 120 V...
A transformer has 380 primary turns and 1140 secondary turns. The input voltage is 120 V and the output current is 16.5A . Assume 100% efficiency. A) What is the output voltage? B) What is the input current?
1. The transformer below has a 120 V primary and a 15 V secondary and is...
1. The transformer below has a 120 V primary and a 15 V secondary and is rated for (S=50 VA). Z2 is 8 Ω. A) If the primary has 2000 turns, how many turns are in the secondary? B) What is the current in the secondary? C) What is the current in the secondary? D) What is the input impedance of the primary? E) What is the minimum value of Z2 for safe operation of the transformation? (Calculate Imax from...
A three-phase wye-connected (Y) synchronous generator is operating at Ea = 8.OLO° kV (lineneutral) and has...
A three-phase wye-connected (Y) synchronous generator is operating at Ea = 8.OLO° kV (lineneutral) and has synchronous reactance of X~ = 1.0 fl . The generator is connected to a threephase delta-wye connected step-down transformer that is constructed from three individual single-phase transformers. Each the single-phase transformers has rated power of 200 kVA has a turns ratio of 4:1 where the rated primary voltage of 8.0 kV and a rated secondary of 2.0 kV and a per-unit series reactance of...
A transformer has 500. primary turns and 10.0 secondary turns. (a) If Vp is 120.V(rms), what...
A transformer has 500. primary turns and 10.0 secondary turns. (a) If Vp is 120.V(rms), what is Vs? If the secondary now has a resistive load of 10.0Ω, what is the current in the (b) secondary and (c) primary? (Hints: Input power equals the output power. Express power in terms of voltage and current, then use Faraday’s Law to relate voltage to number of turns and change of flux. If the primary and the secondary are connected via a closed...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT