Question

A three-phase industrial load consists of 136 kW at 0.8 power factor lagging. What size capacitor...

A three-phase industrial load consists of 136 kW at 0.8 power factor lagging. What size capacitor bank is required to correct the power factor to 0.95 lagging

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A 3 phase, 3.3 kV industrial plant has an overall power factor of 0.88 lagging. A...
A 3 phase, 3.3 kV industrial plant has an overall power factor of 0.88 lagging. A 200 kVA synchronous motor is added to the system and is run at zero power factor and slightly reduced rating to provide power factor correction only. The total load is then 350 kVA at unity power factor. It was then decided to run the synchronous machine at its rated kVA and use it as a source of mechanical power, what gross mechanical power would...
A single-phase load consumes 10kW at 0.9 power factor, power factor lagging at 220V.What is the...
A single-phase load consumes 10kW at 0.9 power factor, power factor lagging at 220V.What is the magnitude and phase angle of current drawn from the source? If another single-phase load rated at 10kW and 0.8 leading power factor is connected in parallel to the sources, what is the magnitude of the current drawn? What is the current drawn from Source? Give your answer in polar form.
1. A single phase circuit has a load of 500kVa at a power factor of 0.707...
1. A single phase circuit has a load of 500kVa at a power factor of 0.707 lagging. Calculate the kVA of the capacitors needed to improve the power factor to unity 3. When connected to a 120-v(rms), 60Hz power line, a load absorbes 4 kw at a lagging power factor of 0.8. Find the capacitance necessary to raise the pf to 0.9 4. A three phase motor draws 20kva at 0.707 power factor lagging from a 208V source. Determine the...
A 10kW load with 0.65 pf lagging is supplied by an AC source rated 400V. A.)...
A 10kW load with 0.65 pf lagging is supplied by an AC source rated 400V. A.) draw the power triangle of the load B.)If a capacitor is connected across the load to correct its power fctor to 0.95 lagging, what will be the required size of the capacitor bank in kVAR? C.) Draw the new power triangle of the system. D.) what will be the new system current
A 15kw single phase load connected to an alternator at 230v and a power factor of...
A 15kw single phase load connected to an alternator at 230v and a power factor of 0.6lag. Determine ?minimum alternator rating, current carrying capacity of the cables, minimum kVA rating of capacitor bank to increase power factor to 0.8
THESE ARE QUESTION FROM THE TOPIC POWER FACTOR IMPROVEMENT FROM THE SUBJECT POWER SYSTEM FUNDAMENTALS PLEASE...
THESE ARE QUESTION FROM THE TOPIC POWER FACTOR IMPROVEMENT FROM THE SUBJECT POWER SYSTEM FUNDAMENTALS PLEASE DO THE QUESTIONS STEP BY STEP AND IN NEAT HAND WRITTING THE ANSWERS ARE GIVEN WITH THE QUESTIONS 1) 1. What should be the kVA rating of a capacitor which would raise the power factor of load of 100 kW from 0·5 lagging to 0·9 lagging    ANS (125 KVA) 2)    A 3-phase, 50 Hz, 3300 V star connected induction motor develops 250 H.P....
A single-phase motor takes 8.3 A at a power factor of 0.866 lagging when connected to...
A single-phase motor takes 8.3 A at a power factor of 0.866 lagging when connected to a 230 V, 50 Hz supply. Two similar capacitors are connected in parallel with each other to form a capacitance bank. This capacitance bank is now connected in parallel with the motor to raise the power factor to unity. Determine the capacitance of each capacitor
Example: The load with lagging 0.8 PF absorbs 60 watts of a 100 V, 60 Hz...
Example: The load with lagging 0.8 PF absorbs 60 watts of a 100 V, 60 Hz power line. Required to correct power factor to 0.9 lag. Find: 3- The original and last line current b) The value of the element to be added to achieve the required pf correction ... power factor
Electrical Circuit A) A factory (with frequency 60 HZ) has the following electrical loads: Induction motors   ...
Electrical Circuit A) A factory (with frequency 60 HZ) has the following electrical loads: Induction motors    of 16 kW at a lagging power factor of 0.8. Induction motors    of 20 kW at a lagging power factor of 0.7. Load of 12 KVA at a lagging factor of 0.9. Load of 10 KVAR at a leading factor of 0.8 a-what is the overall power factor of the factory. b- Assume that the voltage at the input to the factory is 440...
A 400-k VA, 2300 230, 60-hz transformer supplies a 0.8 lagging power-factor load whose KVA Is...
A 400-k VA, 2300 230, 60-hz transformer supplies a 0.8 lagging power-factor load whose KVA Is adjustable from no load to 120 percent rated KVA. The percent resistance, percent reactance, and percent core loss are 56, 3.16, and 0.42 respectively. For 2 KVA increments of load, tabulate and plot the efficiency of the transformer from no load to 120 percent rated load. Please state the formulas clearly