Question

1. A dc motor connected to a 240 V line produces a mechanical output of 160...

1. A dc motor connected to a 240 V line produces a mechanical output of 160 hp.Knowing that the losses are 12 kW, calculate the input power and the line current.

2. An electric motor driving a skip hoist withdraws 1.5 metric tons of minerals from a trench 20 m deep every 30 seconds. If the hoist has an overall efficiency of 94 percent, calculate the power output of the motor in horsepower and in kilowatts.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Q4) A three-phase, 104 kW, 3300 V, 50 Hz, Y-connected induction motor delivers full output power...
Q4) A three-phase, 104 kW, 3300 V, 50 Hz, Y-connected induction motor delivers full output power to a load connected to its shaft. The full-load slip is 0.02 and full-load power factor is 0.85 lagging. If the stator copper loss is 2400 W, the stator core loss is 3500 W, and the friction and windage loss is 1200 W. Calculate: (i) The developed mechanical power. (ii) The air gap power. (iii) The rotor copper loss. (iv) The efficiency of the...
A 200 V DC, 1,800 RPM shunt connected motor has an armature resistance of 0.4 ohm...
A 200 V DC, 1,800 RPM shunt connected motor has an armature resistance of 0.4 ohm and a brush resistance of 0.4 ohm; brush voltage drop of 6.0 V, independent of load. The resistance of the shunt field is 230 ohm. The full load rated line current is 40 A. When the motor is operated at no load the line current is 5 A and the speed is 1750 RPM. Calculate speed at rated load Calculate speed at .3 rated...
A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full...
A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full load slip of 5%. What is the output power of this motor in kW? If friction and windage loss is 350 watts, what is the gross mechanical output at full load? What is the gross torque of this motor at full load? What is the rotor cupper loss at full load? If the efficiency of this motor is 90% at full load what is...
A three phase, 200 kW, 2300 V, 50 Hz star (wye) connected non-salient rotor synchronous motor...
A three phase, 200 kW, 2300 V, 50 Hz star (wye) connected non-salient rotor synchronous motor has a synchronous reactance of 11 Ohms per phase. When it draws 175 kW the power angle is 10 electrical degrees. Neglect the ohmic losses. a. Determine the excitation voltage per phase. b. Calculate the supply line current. c. Determine the supply power factor. d. Draw the phasor diagram. e. By what percentage should the field current be changed to minimize the line current.