Question

A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full...

A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full load slip of 5%.

What is the output power of this motor in kW?

If friction and windage loss is 350 watts, what is the gross mechanical output at full

load?

What is the gross torque of this motor at full load?

What is the rotor cupper loss at full load?

If the efficiency of this motor is 90% at full load what is the input power

Calculate the sum of stator cupper loss and core loss at full load.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Question A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a...
Question A 208 V 10 Hp four pole 60 Hz Y connected induction motor has a full load slip of 5%. a)-What is the synchronous speed of this motor? b)-What is the shaft speed of this motor at full load? c)-What is the frequency of rotor current at full load? d)-What is the shaft torque of this motor at full load? e)-If the efficiency of this motor is 90% at full load what is the input power f)-If the efficiency...
Q4) A three-phase, 104 kW, 3300 V, 50 Hz, Y-connected induction motor delivers full output power...
Q4) A three-phase, 104 kW, 3300 V, 50 Hz, Y-connected induction motor delivers full output power to a load connected to its shaft. The full-load slip is 0.02 and full-load power factor is 0.85 lagging. If the stator copper loss is 2400 W, the stator core loss is 3500 W, and the friction and windage loss is 1200 W. Calculate: (i) The developed mechanical power. (ii) The air gap power. (iii) The rotor copper loss. (iv) The efficiency of the...
A three phase Wye-connected 460 v, 4 poles, 60 Hz wound rotor induction motor has the...
A three phase Wye-connected 460 v, 4 poles, 60 Hz wound rotor induction motor has the following parameters: R1=0.3, R2=0.15, X1=0.5, X2=0.2, Xm=14 The total friction, windage, and core loss is constant at 400 w. The motor is working at its rated voltage and drives its load at 1764 rpm. a)Calculate the input current and the input power. b)Calculate the output mechanical power and torque and motor efficiency. c)Calculate the starting current of this motor and compare it with its...
Problem 1: A 800 V, 4 pole, 3 phase, and 50 Hz star connected induction motor...
Problem 1: A 800 V, 4 pole, 3 phase, and 50 Hz star connected induction motor has a rotor resistance and reactance per phase equal to 0.02 ohm and 0.2 ohm respectively. Determine 1) starting torque 2) slip at which maximum torque will occur 3) speed at which maximum torque will occur 4) Maximum torque 5) full load torque if full load slip is 8%. Assume ratio of stator to rotor turns as 8.
Q1. A 440 V, 60 Hz, six-pole, 3 phase induction motor is taking 50 kVA at...
Q1. A 440 V, 60 Hz, six-pole, 3 phase induction motor is taking 50 kVA at 0.8 power factor and is running at a slip of 2.5 percent. The stator copper losses are 0.5 kW and rotational losses are 2.5 kW. i) The rotor copper losses ii) The shaft hp iii) The efficiency iv) The shaft torque
A 37.3 kW, 3 phase, 4 pole, 50 Hz, induction motor has a full load efficiency...
A 37.3 kW, 3 phase, 4 pole, 50 Hz, induction motor has a full load efficiency of 85%. The friction and windage losses are one third of the no load losses and the copper loss equals the iron loss at full load. Find the full load speed. Stator resistance may be neglected. [Answer: 1401.3 rpm]
A three-phase, 280 V, 60 Hz, 20 hp, 1710 r/m. Y-connected induction motor has the following...
A three-phase, 280 V, 60 Hz, 20 hp, 1710 r/m. Y-connected induction motor has the following impedances in ohms per phase referred to the stator circuit: R1=0.12 Ω.                Rˈ2=0.1 Ω X1=Xˈ2=0.25 Ω        Xm=10 Ω A total rotational loss are 400 W. The core loss is lumped in with the rotational losses. For a slip of 0.05 at the rated voltage and rated frequency. Find: a) The numbers of poles of the motor. b) The stator current. c) the power factor...
a 460-V 100-hp 60-Hz 4 pole Y connected synchronous motor has a operating power factor 0.85...
a 460-V 100-hp 60-Hz 4 pole Y connected synchronous motor has a operating power factor 0.85 leading the aramature resistance is o.2 ohms and synchronous reactance is 12 ohms at full load the efficiency is 85% find the sum of mechanical loss core loss and stray loss when meachine is operating at full load
Problem 3: A 3-phase, 4 pole, 50 Hz induction motor is supplied by 200 V supply....
Problem 3: A 3-phase, 4 pole, 50 Hz induction motor is supplied by 200 V supply. Its full load slip is 2%. At full load, stator copper losses are same as rotor copper losses. Stator iron losses are 50% more than stator copper losses. Mechanical losses are one third of no load losses. Full load output is 50 H.P. Calculate the efficiency on full load.
The following test data apply to a 7.5-hp, three-phase, 220-V, 19-A,60-Hz, four-pole induction motor with a...
The following test data apply to a 7.5-hp, three-phase, 220-V, 19-A,60-Hz, four-pole induction motor with a double-squirrel-cage rotor of design class C (high-starting-torque, low-starting current type): Test 1: No-load test at 60 Hz; Applied voltage V = 219 V line-to-line; Average phase current I1,nl = 5.70 A; Power Pnl =380 W; Test 2: Blocked-rotor test at 15 Hz; Applied voltage V = 26.5 V line-to-line; Average phase current ll,bl = 18.57 A; Power Pbl = 675 W; Test 3: Average...