Question

Describe, how an ion-selective electrode works. State four types of ion-selective electrodes.

Describe, how an ion-selective electrode works. State four types of ion-selective electrodes.

Homework Answers

Answer #1

the ion-selective electrode is basically sensors that convert the concentration of specific ion into the electrical potential.

it consists of the reference electrode and indicator electrode (where specific ion detected) and the ion-selective membrane that allows only specific ions to reach near the indicator electrode (where the ions are detected). since the potential of reference is constant so any change in voltage contains the information about the concentration of ions near the indicator electrode.

types of ion-selective electrodes

1) glass membrane

2) solid-state electrode

3) liquid-based electrode

4) compound electrode

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Why should you wait to put an ion-selective electrode or ph electrode in solution to write...
Why should you wait to put an ion-selective electrode or ph electrode in solution to write down our measurements/ what is happening during this time? Why should we nevee submerge an ion-selectice electrode in deionized water?
[Ion selective electrode] If some of your F- was bound to Ca2+, how would your measured...
[Ion selective electrode] If some of your F- was bound to Ca2+, how would your measured voltage signal change? Background Info (might be useful): For this lab, you will determine the fluoride content in commercial mouthwashes using an ion selective electrode. This lab uses the direct potentiometry method, which assumes that matrix interferences are not a problem for determining the concentration of fluoride in toothpaste. To combat possible matrix problems, the total ionic strength adjustment buffer (TISAB) solution used in...
Determination of Fluoride in Toothpaste with a Fluoride Ion-Selective Electrode lab. 1. The electrode also responds...
Determination of Fluoride in Toothpaste with a Fluoride Ion-Selective Electrode lab. 1. The electrode also responds to OH-. Why doesn't this cause an error in the analysis, or does it? 2. What is the theoretical value of the slope of the graph? 3. What is the significance of the intercept? 4. Is the Oxford-University water supply fluoridated? Should it be? Why?
When an ion-selective electrode for X was immersed in 0.0240 M XCl, the measured potential was...
When an ion-selective electrode for X was immersed in 0.0240 M XCl, the measured potential was 0.0270 V. What is the concentration of X when the potential is 0.0420 V? Assume that the electrode follows the Nernst equation, the temperature is at 25°C, and that the activity coefficient of X is 1.
The calcium ion selective electrode (ISE) measures 11.8 mV in a 1 mM Ca2+ solution at...
The calcium ion selective electrode (ISE) measures 11.8 mV in a 1 mM Ca2+ solution at room temperature. Then the ISE is placed in another solution at body temperature and it measures 20 mV. What is the calcium concentration of the new solution? To avoid complicated theory assume that Eo is not Temperature dependent.
A standard solution of ammonia is 100.0 ppm. You use an ion selective electrode (ISE) to...
A standard solution of ammonia is 100.0 ppm. You use an ion selective electrode (ISE) to measure ammonia of this standard solution and obtain the following data (in ppm): 99.4, 101.1, 100.4, 98.0, 99.6. What is the standard deviation of the mean of ammonia (in ppm) determined by the ISE? Report your answer to two significant figures. I got 1.2 and that's incorrect.
Fluoride ion selective electrodes obey the following equation:       E(V) = K - β(0.0592)log[F-] where the fluoride...
Fluoride ion selective electrodes obey the following equation:       E(V) = K - β(0.0592)log[F-] where the fluoride concentration is expressed as mol/L and the temperature coefficient β is normally equal to 1. In a normal calibration procedure you dilute a standard fluoride solution to between 10 and 20 mg/L fluoride ion and then measure the response of the electrode. You then plot the data and do a linear regression to obtain the fitting coefficients K and β. Use the plotting and...
Calibration data for a bromide ion-selective electrode (ISE) was collected and recorded below. The potential of...
Calibration data for a bromide ion-selective electrode (ISE) was collected and recorded below. The potential of the ISE was measured against a saturated calomel electrode (SCE). All solutions were buffered at a pH of 7.56. A linear calibration curve can be constructed from this data as a plot of potential (in mV) vs. pBr. Determine the slope and y-intercept of such a plot of the calibration data given. [Br-](M) Potential (mV) 0.300 -21.2 0.0300 36.7 0.00300 96.0 0.000300 154.7 0.0000300...
Explain how is a pH meter measures the hydrogen ion concentration in an aqueous solution by...
Explain how is a pH meter measures the hydrogen ion concentration in an aqueous solution by describing the principle involved including the overall electrode set up, function of the ion selective membrane
describe the features of the four federal workers compensation plans and the teo types of state...
describe the features of the four federal workers compensation plans and the teo types of state wirkers compebsation benefits
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT