Question

What is the significance of mixing in the following water treatment operations: -Rapid mix -Flocculator -Settling...

What is the significance of mixing in the following water treatment operations:
-Rapid mix

-Flocculator

-Settling basin

Homework Answers

Answer #1

Significance of techniques in water treatment

- Rapid mix : allows us to mix the added coagulant with the water present. Thus a complete and efficient coaggulation of impurities occur without any loss.

- Flocculator : a technique wherein, the particles in water are agitated such that larger masses of particles are formed by agglomeration of many smaller particles together.

- Settling basin : This technique helps in clean decantation or separation of insoluble agglomerated particles from the water. Thw water is settled, heavier particles are at the base and are easily removed.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
1) A drinking water treatment plant uses a cubic rapid mix, rectangular flocculation basin, and rectangular...
1) A drinking water treatment plant uses a cubic rapid mix, rectangular flocculation basin, and rectangular sedimentation basin to treat 10.0 mgd of water. Size the volume for each basin using the characteristic detention time and flow through velocity requirements. What is the rapid mix volume for Dt = 30 sec? What is the floc. basin volume for Dt = 30 min? What is the floc. basin cross-sectional area for a velocity = 10.0 ft/min? What is the sed. basin...
You have been asked to provide a design for a rapid mix tank at a water...
You have been asked to provide a design for a rapid mix tank at a water treatme nt plant which has an average water temperature of 50F. The tank is to have a detention time (td= HRT) of 1.5 seconds, a mixing intensity (G) of 2,000/second, and treat a flow (Q) of 10 mgd. a. Identify the volume of reactor required (in ft^3 and gallons) b. Find the reactor dimensions (i.e., Depth and Diameter, in feet) if the rapid mix...
What are the dimensions and the actual power required for a square rapid-mix basin that is...
What are the dimensions and the actual power required for a square rapid-mix basin that is to be used to treat 0.15 m3/s of water if the detention time is 10 seconds? The depth is assumed to be 1.5 times the width. The velocity gradient is 600 1/s. The average temperature of water is 5 degrees C. The efficiency of the mixer and motor is 80%.?
Design a cubic rapid mixer for a water treatment plant with a peak flow rate of...
Design a cubic rapid mixer for a water treatment plant with a peak flow rate of 20,000 m3/d.  Assume the velocity gradient G in the mixer is to be at least 1,000 s-1and the detention time is at least 10 s. Determine the size of the mixing tank, the power input, and the rotational speed of the mixer if the radial flow impeller power number is 6.0
A square rapid mixing tank is used to process 0.14 m3/s of water. The depth of...
A square rapid mixing tank is used to process 0.14 m3/s of water. The depth of the tank is assumed to be 2 times the width. Use a detention time of 25 seconds and velocity gradient of 700 1/s. The properties of the water in the tank are the same as the ones listed in the formulas sheet. Determine a) The dimensions of the rapid mixing tank b) The power input needed from the motor if its efficiency is 80%
A rectangular horizontal-flow sedimentation basin in a conventional water treatment plant has been designed to treat...
A rectangular horizontal-flow sedimentation basin in a conventional water treatment plant has been designed to treat a flow of 50,000 m3 /day. It has a length = 80 m, width = 20 m, and depth = 3.6 m. For this problem, assume temperature = 20 °C (density of water = 103 kg/m3 and viscosity = 10-3 kg/m·s) and laminar flow. a. What is the hydraulic detention time? Does this meet the typical criteria for this type of sedimentation basin? b....
Design six settling tanks for water treatment plant using the design overflow rate 32. 5 m3/...
Design six settling tanks for water treatment plant using the design overflow rate 32. 5 m3/ day.m2. The maximum day design flow is 0.5m3/s. Assume a water temperature of 10 oC. (take L:W = 13.8: 1 and L:D = 28:1 also take into account freeboard and sludge zone )
A water treatment plant has five identical rapid sand filters. Each is square in plan and...
A water treatment plant has five identical rapid sand filters. Each is square in plan and has a capacity of 1 MGD. The application rate is to be 4 gal/min-ft2 and the total wetted depth is 10 ft. Each filter will be backwashed every day for 5 min. The rate of rise of the backwash water is 2 ft/min. A) What should be the cross-section dimensions of each filter? B) What percentage of the plant's filtered water will be used...
You are trying to remove 10 µm diameter particles in a water treatment plant. The water...
You are trying to remove 10 µm diameter particles in a water treatment plant. The water is at 20 oC and the particle density is 1.2 g/mL. The plant treats 0.4 m3/s of water. It is proposed to use a 3.5 m deep, rectangular sedimentation tank with a length to width ratio of 5:1. What is the minimum required width (in meter) of the basin?
1) What is the additional water content to be added to the mix, if the slump...
1) What is the additional water content to be added to the mix, if the slump has to be maintained at 3 in. when the fresh concrete temperature changes from 60 oF to 80 oF? 2) Suppose the additional water content in question 3 was added to the mix to maintain the required slump of 3 in. while maintaining the same cement content.  What is the water-cement ratio of the mix at 80 oF?