Question

A rectangular horizontal-flow sedimentation basin in a conventional water treatment plant has been designed to treat...

A rectangular horizontal-flow sedimentation basin in a conventional water treatment plant has been designed to treat a flow of 50,000 m3 /day. It has a length = 80 m, width = 20 m, and depth = 3.6 m. For this problem, assume temperature = 20 °C (density of water = 103 kg/m3 and viscosity = 10-3 kg/m·s) and laminar flow.

a. What is the hydraulic detention time? Does this meet the typical criteria for this type of sedimentation basin?
b. What is the overflow rate?
c. What is the diameter of smallest particle that will be completely removed, assuming ideal conditions (no short-circuiting, currents, etc.), if the particles have a specific gravity of 2.5?
d. Calculate the Reynolds number of the settling particles in part (c). Are the particles settling in laminar flow as was stated in the assumption above?

Homework Answers

Answer #1

comment if any doubt regarding the problem thank you

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A conventional, rectangular flocculation basin is 38 ft. wide, 90 ft. long and 16 ft. deep....
A conventional, rectangular flocculation basin is 38 ft. wide, 90 ft. long and 16 ft. deep. The flow through the basin is 24 mgd and the water horsepower input by the reel type paddles is 15 hp. The dynamic viscosity of water is 2.73 E -5 lb/sec/ft2 at 50 degrees Fahrenheit. The flocculation basin in above is followed by four sedimentation basins which operate in parallel.   Each basin is 30 ft. wide, 240 ft. long and has an effective settling...
A rectangular sedimentation basin receives water at 10 degrees Celsius with a flow rate of 0.5...
A rectangular sedimentation basin receives water at 10 degrees Celsius with a flow rate of 0.5 m3/s. The sedimentation basin is 20m wide, 60m long, and 6m deep. The effective settling zone in the sedimentation basin is 45 m long. Determine the number of double sided weir troughs placed parallel to the length (L) of the basin.
1) A drinking water treatment plant uses a cubic rapid mix, rectangular flocculation basin, and rectangular...
1) A drinking water treatment plant uses a cubic rapid mix, rectangular flocculation basin, and rectangular sedimentation basin to treat 10.0 mgd of water. Size the volume for each basin using the characteristic detention time and flow through velocity requirements. What is the rapid mix volume for Dt = 30 sec? What is the floc. basin volume for Dt = 30 min? What is the floc. basin cross-sectional area for a velocity = 10.0 ft/min? What is the sed. basin...
You are trying to remove 10 µm diameter particles in a water treatment plant. The water...
You are trying to remove 10 µm diameter particles in a water treatment plant. The water is at 20 oC and the particle density is 1.2 g/mL. The plant treats 0.4 m3/s of water. It is proposed to use a 3.5 m deep, rectangular sedimentation tank with a length to width ratio of 5:1. What is the minimum required width (in meter) of the basin?
You have been retained to design a wastewater treatment plant using a conventional activated sludge process...
You have been retained to design a wastewater treatment plant using a conventional activated sludge process for a town of 40,000 people. The industrial flow contribution to the sewer system is 300,000 gallons per day. Effluent discharge standards require effluent BOD5 and total suspended solids concentration of <10 mg/l. Assume the following design criteria are applicable: Domestic sewage flow = 100 gal/cap/day (including I/I) BOD loading = 0.18 lbs/cap/day TSS loading = 0.20 lbs/cap/day BOD removal in primary = 33%...
Design high-rate sedimentation tank(s) for a water treatment plant using plate settlers. 1. Design the rectangular...
Design high-rate sedimentation tank(s) for a water treatment plant using plate settlers. 1. Design the rectangular sedimentation tank(s), including launders and sludge collection mechanism. 2. Design the countercurrent plate settlers, including length, angle, and distance between plates (to achieve 100% removal of the target particle described below). 3. Draw a cross-section of the sedimentation tank with dimensions, indicating the concrete walls, main pipes, launders, plate settlers. 4. Quantify/discuss the improvement(s) that may result from installing the plate settlers. Inputs: Design...