Question

d) Why is the resolution of a satellite instrument operating at thermal wavelengths lower than that...

d) Why is the resolution of a satellite instrument operating at thermal wavelengths lower than that of a visible instrument (use an equation to explain this).

Homework Answers

Answer #1

Two objects are separated by a angular separation , then they will be resolved if the is grater than critical value .

is defined as . Where is the wavelength and D is the diameter of the aperture/lens/mirror etc.

For long distance signal, diffraction spreading is very significant. To overcome this, we can increase D. So for satellite instrument operation, one make "D" very larger resulting much smaller.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
d) Use the Spectrum Simulation to investigate changes in the amount of light at visible wavelengths...
d) Use the Spectrum Simulation to investigate changes in the amount of light at visible wavelengths due to this change in temperature from 2500 C to 2000 C. i) What is the approximate ratio between the powers emitted at 500 nm at 2000 degrees C to that at 2500 degrees C, that is, the power emitted at 500 nm at 2000 degrees C divided by the amount of power at 500 nm at degrees 2500 C? ii) In question 1b,...
In gas chromatography, (a) why do open tubular columns yield greater solute resolution than packed columns?...
In gas chromatography, (a) why do open tubular columns yield greater solute resolution than packed columns? (Check all that apply.) A.Open tubular columns have greater sample capacity. B.Open tubular columns eliminate the multiple path term (A) from the van Deemter equation. C.Open tubular columns have a lower resistance to gas flow, so longer columns can be used without increasing solute retention times. -why can more rapid flow rates be used with H2 and He carrier gases than with N2, without...
A. Explain why a 1.0m solution of NaCl in water freezes at a lower temperature than...
A. Explain why a 1.0m solution of NaCl in water freezes at a lower temperature than pure water.    B. Explain why a 1.0m CaCl2 solution in water freezes at a lower temperature than a 1.0m solution of NaCl in water.
in absorption, why cant i use a flowrate lower than the minimum solvent flowrate (Lmin), explain...
in absorption, why cant i use a flowrate lower than the minimum solvent flowrate (Lmin), explain in detail
4. Why is a low-pressure gas or vacuum considered the best thermal insulator possible? Explain. Use...
4. Why is a low-pressure gas or vacuum considered the best thermal insulator possible? Explain. Use your answer to explain why fiberglass insulation used for buildings is loose rather than compact.
Ferrite materials have much lower saturation flux densities than laminated steels. Briefly explain why, despite this,...
Ferrite materials have much lower saturation flux densities than laminated steels. Briefly explain why, despite this, ferrite materials are preferred in magnetic components operating at switched-mode frequencies.
Explain why 2-bromobenzoic acid has a lower pKa than benzoic acid?
Explain why 2-bromobenzoic acid has a lower pKa than benzoic acid?
d) Why do we zero the instrument with the “blank” tube each time we change the...
d) Why do we zero the instrument with the “blank” tube each time we change the wavelength? e) If the Absorbance of one of your unknown solutions was almost twice as great as the absorbance of the most concentrated standard solution, what could you do to still accurately determine its concentration? f) Consumption of methanol leads to blindness and even death. Why do you think methanol consumption is more poisonous than ethanol consumption? (Hint: what is the chemical difference between...
1. Why do molecules absorb light? Why are only certain wavelengths absorbed? 2. Shown below is...
1. Why do molecules absorb light? Why are only certain wavelengths absorbed? 2. Shown below is the absorbance spectrum of CBBG in the presence of a large excess of BSA. The x-axis shows wavelength (in nm) and the y-axis is absorbance – the y-axis is arbitrary since the absorbance depends on the concentration. You’ll notice that the maximum of this absorbance spectrum occurs at 595 nm, which is where you measured the absorbance of the complex. a. Why must we...
Give any two reasons why young school-age children today may have lower vitamin D levels than...
Give any two reasons why young school-age children today may have lower vitamin D levels than children 30֪–40 years ago.