Question

Problem 8.24 Water is used to cool ethylene glycol in a 60-ft-long double pipe heat exchanger...

Problem 8.24

Water is used to cool ethylene glycol in a 60-ft-long double pipe heat exchanger made of 4-std and 2-std (both type M) copper tubing. The water inlet temperature is 60°F and the ethylene glycol inlet temperature is 180°F. The flow rate of the ethylene glycol is 20 lbm/s, while that for the water is 30 lbm/s. Calculate the expected outlet temperature of the ethylene glycol and determine the pressure drop expected for both streams. Assume counterflow, and place the ethylene glycol in the inner tube. Compose a Summary of Performance chart.

Text Book: Design of Fluid Thermal Systems (4th Edition)

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Hot water enters a counter-flow double-pipe heat exchanger at 180F with a velocity of 5 ft/s....
Hot water enters a counter-flow double-pipe heat exchanger at 180F with a velocity of 5 ft/s. Cold water at 80F flows at 3 ft/s in the outer section of the exchanger. The diameter of the inner pipe is 1 inch, the pipe wall thickness is 1/8", and the outer pipe diameter is 2 inches. The overall heat transfer coefficient times area per unit length UA/L = 150 Btu/hr-ft-F. If the exchanger is 16 feet long, what is the exit temperature...
A counter current double pipe heat exchanger is used to boil but not superheat water at...
A counter current double pipe heat exchanger is used to boil but not superheat water at 100 DegreeC at rate of about 0.1 kg/s. This is achieved by flowing hot oil at 400 DegreeC through the inner pipe at a rate of 5 kg/s. Latent heat of water: 2265 kJ/kg Heat capacity of water: 4180 J/kgK Heat capacity of the oil: 1800 J/kgK What is the temperature of he hot oil leaving the heat exchanger? What is the overall heat...
A thin-walled double pipe counter flow heat exchanger is to be used to cool oil (cp...
A thin-walled double pipe counter flow heat exchanger is to be used to cool oil (cp = 2200 j/kg*K) from 150 ℃ to 30 ℃ at a rate of 2.1 kg/s by water (cp= 4180 J/kg*K) that enters at 20 ℃ at a rate of 1.2 kg/s. The diameter of the tube is 2.5 cm, and its length is 10 m. Using Excel (a) Determine the overall heat transfer coefficient of this heat exchanger. (b) Investigate the effects of oil...
heat transfer problem A counterflow concentric tube heat exchanger is used to cool lubricant oil of...
heat transfer problem A counterflow concentric tube heat exchanger is used to cool lubricant oil of a big gas turbine. The cooling water's flow rate through the interior aluminum tube (Di= 25mm) is 0.2kg/seg, while the oil's flow rate through the exterior ring (Do= 45mm) is 0.1kg/seg. The oil and the water enter at 100°C and 30°C respectively. How long does the tube have to be for oil to leave at 60°C? Oil at 80°C Cp = 2131 J/Kg K...
City water will be cooled in a heat exchanger by sea water entering at 15°C. The...
City water will be cooled in a heat exchanger by sea water entering at 15°C. The outlet temperature of the sea water is 20°C. City water will be recirculated to reduce water consumption. The suction line of the pump has an inner diameter of 154 mm, is 22 m long, and has two 90° bends and a hinged check valve. The pipe from the pump to the heat exchanger has an inner diameter of 127 mm, is 140 m long,...
a tube-within-a-tube heat exchanger operating at steady state is composed of one pipe containing Refrigerant 134a...
a tube-within-a-tube heat exchanger operating at steady state is composed of one pipe containing Refrigerant 134a and another pipe containing an ideal gas with constant specific heat at constant pressure of 1.2 kJ/(kg∙K). The refrigerant 134a enters the heat exchanger in a saturated liquid state and exits the heat exchanger in a saturated vapor state. The temperature and mass flow rate of the refrigerant 134a are -20° C and 3 kgs/s, respectively, at both its inlet and outlet. The ideal...
The properties of the fluid are: density 895 kg/m3, viscosity 0.76 mNm-2s. A double-pipe heat exchanger...
The properties of the fluid are: density 895 kg/m3, viscosity 0.76 mNm-2s. A double-pipe heat exchanger is to be used to heat 6000 kg/h of 22 mol per cent hydrochloric acid. The exchanger will be constructed from karbate (impervious carbon) and steel tubing. The acid will flow through the inner, karbate, tube and saturated steam at 100ºC will be used for heating. The tube dimensions will be: karbate tube inside diameter 50 mm, outside diameter 60 mm; steel tube inside...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free