Question

Discuss why a standard curve is required to measure the unknown protein concentration.

Discuss why a standard curve is required to measure the unknown protein concentration.

Homework Answers

Answer #1

How standard curve drawn: (protein concentration vs absorbance)

Multiple samples with known properties are measured and graphed (standard curve), and same properties to be determined for unknown samples by interpolation on the graph.

Determining the concentration of a protein in an unknown sample by comparing the unknown to a set of standard samples of known concentration

The standard curve is required for measuring unknown protein concentration in a simple, sensitive and accurate manner.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
During the spectrophotometric analysis of an unknown, the absorbance of a solution of unknown concentration is...
During the spectrophotometric analysis of an unknown, the absorbance of a solution of unknown concentration is measured, and the value is higher than the highest standard used to make the standard curve. What should be done to make sure that the standard curve can be used to determine the concentration of the unknown? A) Dilute the unknown so that it will have an absorbance within the standard curve. Once the diluted unknown concentration is determined, the full strength concentration can...
You are performing a Bradford assay. You construct your standard curve (concentration in mg/mL on the...
You are performing a Bradford assay. You construct your standard curve (concentration in mg/mL on the x-axis, Absorbance on the y-axis) and derive a trendline with an equation of y = 0.25x (the intercept is set to zero because you blanked your spectrophotometer correctly). You dilute protein A using the volumes given below, to a final volume of 1000 μL, and measure the absorbance: 6 μL to 1000 μL = Abs 0.04 80 μL to 1000 μL = Abs 0.15...
STANDARD CURVE PREPARATION Always indicate the volume of water (or additional solution) to be added to...
STANDARD CURVE PREPARATION Always indicate the volume of water (or additional solution) to be added to complete any dilution. a) A stock solution of 6mg/ml BSA is provided. Calculate the dilutions for the preparation of the following BSA standards (2.0ml volumes of each): 60, 170, 500, 1500, 3000ug/ml. Also include the dilution factor for each preparation. On a separate sheet of paper with a heading of Calculations, include one complete sample calculation of this dilution calculation. b) To 0.5ml of...
The standard curve generated from his data is y=16.943x+0.0077 (absorbance on the y-axis and concentration on...
The standard curve generated from his data is y=16.943x+0.0077 (absorbance on the y-axis and concentration on the x-axis • Mass of unknown nickel salt he used to prepare 25 mL of solution: 0.2755g. • Absorbance reading of unknown nickel salt solution (at appropriate wavelength): 0.436. Calculate the mass% of Sulfate. Please show work
2. A linear standard curve of KMnO4KMnO4 is prepared from a set of standard solutions by...
2. A linear standard curve of KMnO4KMnO4 is prepared from a set of standard solutions by plotting absorbance (y) vs. concentration (x). Use Google Sheets/Excel to plot this standard curve using the data in Table 1. Table 1: Data for the standard curve of KMnO4 Absorbance Concentrations (M) 0.210 6.00E-4 0.168 4.80E-4 0.126 3.60E-4 0.0840 2.40E-4 0.0420 1.2E-4 After plotting the standard curve, enter its slope below (not the equation of the line). Report your answer to 3 significant figures....
The transmittance of a solution 1.00cm thick of unknown concentration is 0.700. The transmittance of a...
The transmittance of a solution 1.00cm thick of unknown concentration is 0.700. The transmittance of a standard solution of the same material is also 0.700. The concentration of the standard solution is 100.0 ppm; the cell length of the standard is 4.00 cm. What is the concentration of the unknown solution?
Why is the standard normal curve so useful? Why do we use the standard normal curve...
Why is the standard normal curve so useful? Why do we use the standard normal curve to find percentiles instead of the normal curve of the original data?
A lab group obtained the following equation for their calibration curve for a series of dilutions:...
A lab group obtained the following equation for their calibration curve for a series of dilutions: y = 17.711x + 0.104. They measure the absorbance of a solution of unknown concentration and found that absorbance to be 0.349. What is the concentration of their unknown solution (in Molarity)?
8. Discuss why the Real GDP is a good measure of a countries economic well being...
8. Discuss why the Real GDP is a good measure of a countries economic well being and why it is a poor measure. a. (5 points) Why is the real GDP a good measure. b. (5 points) Why is the real GDP a poor measure.
1a. Give a full molecular description rationalising why protein requires a relatively high concentration of ammonium...
1a. Give a full molecular description rationalising why protein requires a relatively high concentration of ammonium sulphate for it to precipitate . 1b.Explain at a molecular level the difference between modes of action of (i) a lyotropic salt, and (ii) a chaotropic salt for a protein molecule  