Question

Question 9, A series of 33 samples of size 100 have been produced. The total number...

Question 9,

A series of 33 samples of size 100 have been produced. The total number of defectives in the samples is 51. Determine the fraction of nonconforming product control chart upper limit.

I need the correct answer, please!

Homework Answers

Answer #1

ANSWER:

Given that:

A series of 33 samples of size 100 have been produced. The total number of defectives in the samples is 51

Number of samples m = 33.00

Sample size n = 100

Total number of units mn = 3300.00

Number of defects d = 51.00

Hence non conforming fraction

Upper control limit (UCL) =

=

=

=

**Please give me "like".....don't skip....its very important for me now.....

NOTE:: I HOPE YOUR HAPPY WITH MY ANSWER....***PLEASE SUPPORT ME WITH YOUR RATING...

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A series of 33 samples of size 100 have been produced. The total number of defectives...
A series of 33 samples of size 100 have been produced. The total number of defectives in the samples is 51. Determine the fraction of nonconforming product control chart upper limit Determine the Average Run Length (ARL) of a x-bar chart with limits where the process has shifted 0.25 times the standard deviation in one direction
A. A series of 33 samples of size 100 have been produced. The total number of...
A. A series of 33 samples of size 100 have been produced. The total number of defectives in the samples is 51. Determine the fraction of nonconforming product control chart upper limit      B. Determine the Average Run Length (ARL) of a x-bar chart with limits where the process has shifted one standard deviation in one direction     C. A product has a target length of 20.0 cm, and the process has a standard value for the standard deviation of 0.05 cm....
A series of 33 samples of size 100 have been produced. The total number of defectives...
A series of 33 samples of size 100 have been produced. The total number of defectives in the samples is 51. Determine the proportion of defective product
A series of 20 samples of size 4 has been drawn from a project. The measure...
A series of 20 samples of size 4 has been drawn from a project. The measure of interest has an average of 20.0443, and the average standard deviation of the samples is 0.032. Determine the sigma-bar control chart lower limit A series of 20 samples of size 4 has been drawn from a project. The measure of interest has an average of 20.0443, and the average range within the samples is 0.0567. Determine the control chart lower limit for R...
The results of inspection of DNA samples taken over the past 10 days are given below....
The results of inspection of DNA samples taken over the past 10 days are given below. Sample size is 100. Day 1 2 3 4 5 6 7 8 9 10 # of defectives 7 6 6 9 5 0 0 8 6 1 (a) Determine the fraction defective of the p chart. Please give the formula and at least one step of calculation for full credit. (6 points) (b) Determine the of the p chart. Please give the formula...
Edit question The results of inspection of samples of a product taken over the past 5...
Edit question The results of inspection of samples of a product taken over the past 5 days are given below. Sample size for each day has been 100: Day        1             2             3             4             5 Defectives           2             6             14           3             7 Determine the UCL for this chart Determine the LCL for this chart Is this process in control?
A. A product has a target length of 20.0 cm, and the process has a standard...
A. A product has a target length of 20.0 cm, and the process has a standard value for the standard deviation of 0.05 cm. Calculate the x-bar control chart lower limit when the sample size is 5 B. A product has a target length of 20.0 cm, and the process has a standard value for the standard deviation of 0.05 cm. Calculate the standard deviation control chart upper limit when the sample size is 5 C. A series of 20...
The following samples have been taken from an on-going process. Use these values to create both...
The following samples have been taken from an on-going process. Use these values to create both an X bar and an R chart, and then answer the questions below. Please show work. Sample 1: 56 48 53 58 52 Sample 2: 50 59 57 56 54 Sample 3: 61 59 56 55 58 Sample 4: 57 51 49 57 50 Sample 5: 50 49 57 55 56 Sample 6: 56 55 60 58 57 A) What is the value of...
QUESTION 20 Five samples of size 12 were collected. The data are provided in the following...
QUESTION 20 Five samples of size 12 were collected. The data are provided in the following table: Sample number 1 2 3 4 5 Sample mean 4.80 4.62 4.81 4.55 4.92 Sample standard deviation 0.30 0.33 0.31 0.32 0.37 The upper control limit (UCL) and lower control limit (LCL) for an s-chart are: 1.LCL = 0.0971, UCL = 0.5868. 2.LCL = 0.1154, UCL = 0.5366. 3.LCL = 0.1011, UCL = 0.6109. 4.LCL = 0.1034, UCL = 0.6246. 5.LCL = 0.0994,...
A company collects 20 samples with 100 eggs in each sample. They want to construct a...
A company collects 20 samples with 100 eggs in each sample. They want to construct a P chart to track the proportion of broken eggs in each sample. The table below shows the number of defective eggs per sample. Sample Eggs 1 3 2 5 3 3 4 4 5 2 6 4 7 2 8 6 9 4 10 9 11 2 12 6 13 5 14 1 15 5 16 0 17 2 18 6 19 2 20...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT