Question

What value of B should be used in a velocity selector to separate out 2.0 keV...

What value of B should be used in a velocity selector to separate out 2.0 keV protons if E is fixed at 94 kV/m?

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
1) A mass spectrometer was used in the discovery of the electron. In the velocity selector,...
1) A mass spectrometer was used in the discovery of the electron. In the velocity selector, the electric and magnetic fields are set to only allow electrons with a specific velocity to exit the fields. The electrons then enter an area with only a magnetic field, where the electron beam is deflected in a circular shape with a radius of 8.0 mm. In the velocity selector, E = 400.0 V/m and B = 4.7 x 10-4 T. The same value...
A velocity selector consists of electric and magnetic fields described by the expressions E = E...
A velocity selector consists of electric and magnetic fields described by the expressions E = E k and B = B ĵ, with B = 25.0 mT. Find the value of E (in kV/m) such that a 770 eV electron moving in the negative x-direction is undeflected.
Consider the following apparatus for measuring the charge per mass (q/m) ratio of the proton. This...
Consider the following apparatus for measuring the charge per mass (q/m) ratio of the proton. This apparatus employs the same physics as in mass spectrometers. It consists of a pair of plates that accelerate a beam of protons starting from rest at the left-most plate to a speed of 1 x 107 m/s, followed by a velocity selector set to only pass this speed, and a final set of deflector plates. (a) The left side of the accelerator plate is...
A mass spectrometer is used to separate isotopes. If the beam emerges with a speed of...
A mass spectrometer is used to separate isotopes. If the beam emerges with a speed of 253 km/s and the magnetic field in the mass selector is 4.0 T, what is the distance in mm between where the following ions are detected? Remember that the ions trace a semicircular path before being detected. Note: the superscript number in the following says how many nucleons (protons and neutrons) are contained in the ion. The mass of a nucleon is 1.66 10-27...
A beam of electrons is accelerated through a potential difference of 10 kV before entering a...
A beam of electrons is accelerated through a potential difference of 10 kV before entering a velocity selector. If the B-field of the velocity selector has a value of .010 T, what value of the E-field is required if the particles are to be undeflected? I have the answer. It is 5.9 x 10^5 V/m. Please thouroughly explain how to get to this answer and what undeflected means.
A certain commercial mass spectrometer is used to separate uranium ions of mass 3.92 × 10-25...
A certain commercial mass spectrometer is used to separate uranium ions of mass 3.92 × 10-25 kg and charge 3.20 × 10-19 C from related species. The ions are accelerated through a potential difference of 109 kV and then pass into a uniform magnetic field, where they are bent in a path of radius 1.13 m. After traveling through 180° and passing through a slit of width 1.19 mm and height 0.879 cm, they are collected in a cup. (a)...
5. Some cyclotrons used to produce radionuclides in nuclear medicine for cancer treatment are adjusted to...
5. Some cyclotrons used to produce radionuclides in nuclear medicine for cancer treatment are adjusted to accelerate deuterons. One example uses a dee radius of 0.5 m with an oscillator frequency of 11 MHz. (a) What magnetic field is required? (b) What is the final energy of the deuterons? (c) Assuming an acceleration potential between the dees of 100 kV, estimate the path length traveled by a deuteron during the acceleration process. At times one would like to use the...
1. A diffraction grating is used to separate the spectral lines of light, emanating from a...
1. A diffraction grating is used to separate the spectral lines of light, emanating from a gas discharge tube (e.g., a neon light), that is normally incident on the grating. On a screen placed 2.0 m from the grating, the third-order (m = 3) interference maximum for violet light (λ = 4.4 × 10−7 m) is found to be 0.20 cm farther from the location of the central maximum (m = 0) on the screen than the second-order maximum of...
The information below is used for the next two questions. A and B have maintained separate...
The information below is used for the next two questions. A and B have maintained separate accounting practices in the Hattiesburg area. A has been in accounting practice for nearly 20 years whereas B has been practicing for 5 years. On 1/1/X1, A and B have decided to form the A&B accounting partnership. A will contribute $100,000 of cash and will bring in a large client portfolio while B will contribute a building having a $300,000 fair value. Under the...
A mass spectrometer is a device for separating particles of different masses from a mixture. For...
A mass spectrometer is a device for separating particles of different masses from a mixture. For example, the technology is used to investigate qualitative and quantitative changes within thousands of biologically active components such as proteins, lipids and metabolites. A mass spectrometer consists of three sections: The accelerator The velocity selector The magnetic chamber (1) Accelerator (acc): In the accelerator, there is only an uniform Electric field due to a potential difference Vacc across two vertical plates separated from a...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT