Question

A coal-fired power plant (PP) has a rated power of 1000 MWe. It works at 100%...

A coal-fired power plant (PP) has a rated power of 1000 MWe. It works at 100% capacity (base-loaded) at a thermal efficiency of 35%. It burns coal having a heating value of 30 MJ/kg and a sulfur content of 2% by weight, a nitrogen content of 1% by weight, and a mineral (ash) content of 10% by weight. b) How much coal does the PP consume per year (ton/yr) ? 3*106 tons/yr c) How much SO2 does the PP emit per year (ton/yr)? 120 000 tons/yr d) How much NO2 does the PP emit per year (ton /yr), assuming “thermal” NO2 formation doubles the rate of “fuel” NO2 emissions? (Note that NO2 has 3.28 times the molecular weight of N). 196 800 tons/year Total NO2 emission= Thermal NO2 emission+ Fuel NO2 emission = 2*Fuel NO2 emission e) How much fly ash does the PP emit per year (ton/yr)? Assume all mineral content is emitted as fly ash. 300 000 tons /yr

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A power plant burns 100 metric tons of coal per day with a sulfur content of...
A power plant burns 100 metric tons of coal per day with a sulfur content of 5%. The coal contains 3% ash (noncombustible portion). Samples of the ash show that it has a sulfur content of 10% sulfur by weight. Sulfur that is not in the ash is in the flue gases. How many metric tons of SO2 are emitted from the smoke stack each day? (Hint: Apply mass balance to find the amount of sulfur leaving the power plant...
Calculate the emissions reductions if a coal-fired power plant is converted to wood pellets. The biomass...
Calculate the emissions reductions if a coal-fired power plant is converted to wood pellets. The biomass burned by the power plant is fully regrown but 19% of the harvest is consumed during processing of the biomass. Furthermore, the transportation of wood and wood pellets from source to power plant requries 273 litres of diesel per ton of wood pellet delivered. Treat the diesel as pure cetane and the wood pellets are pure carbohydrate chains. Fuel Properties -Calorific value of coal:...
A typical coal-fired power plant generates 1000 MW of usable power at an overall thermal efficiency...
A typical coal-fired power plant generates 1000 MW of usable power at an overall thermal efficiency of 40%. PART A: What is the rate of heat input to the plant? Answer in MW PART B: The plant burns anthracite coal, which has a heat of combustion of 2.65×107J/kg. How much coal does the plant use per day, if it operates continuously? Answer in kg PART C: At what rate is heat ejected into the cool reservoir, which is the nearby...
20. [1pt] A coal-fired power plant burns 2000.0 tons of coal a day. Assume that 95%...
20. [1pt] A coal-fired power plant burns 2000.0 tons of coal a day. Assume that 95% of the weight of the coal is carbon that is combusted into CO 2. How many tons of CO2 does this plant release every day? A) 7,000 B) 950 C) This is the only guaranteed wrong answer - do not enter it - you will be locked out of this problem D) 14,000 E) 3,500 F) 10,500
In this exercise we will consider two coal-fired power plants and a solar thermal plant, in...
In this exercise we will consider two coal-fired power plants and a solar thermal plant, in order to compare their power densities, i.e., their power output vs. the amount of land they occupy. This method of comparison of diverse forms of renewable and non-renewable energy systems was pioneered by Vaclav Smil of the University of Manitoba in Canada. The first coal plant is highly efficient and is optimally located, next to a mine that supplies high-quality coal from a thick...
A thermal power plant has received a coal sample. The plant manager is required to analyse...
A thermal power plant has received a coal sample. The plant manager is required to analyse if the auxiliary equipment and the combustion systems are ready for burning this fuel. For determining the suitability of burners and auxiliary systems, some adequate analyses are needed. The coal sample has the following ultimate analysis. Element Weight / kg C 0.7300 H2 0.0590 O2 0.0790 N2 0.0270 S 0.0185 Ash 0.0865 Total 1.0000 Determine the amount of air required for complete combustion of...
1) A coal fired power plant produces 1.00x10^14 J per day by burning coal. If the...
1) A coal fired power plant produces 1.00x10^14 J per day by burning coal. If the efficiency is 40.0%, how much work does the turbines do? 2) How much energy is lost to the environment (as heat)? 3) If 1 kg of coal can produce 2.5x10^6 J, and 1 kg of coal produces 3.67 kg of CO2, how much CO2 is produced in a year from this plant? 4) If there are 1000 such power plants worldwide, how long will...
4. Petacalco is a coal-fired power plant in La Union, Guerrero. In 2002, it had an...
4. Petacalco is a coal-fired power plant in La Union, Guerrero. In 2002, it had an installed capacity of 2100 MW, and produced 13,870.47 GWh. To produce this amount of energy, the plant used 957.53 m3 of fuel oil, 3631.24 kt of bituminous coal, and 6650 m3 of diesel. Diesel and fuel oil were burned in boilers having a normal configuration; while coal was burned in a wett-bottom furnace. Estimate the total amount of CO2 emitted to the atmosphere during...
A coal-burning power plant that uses an evaporating water tower to cool the generated steam has...
A coal-burning power plant that uses an evaporating water tower to cool the generated steam has the following characteristics: uses about 2,000 metric tons/day of bituminous coal, has an overall efficiency of 35% in converting the energy from the combustion of coal to electricity, and 10% of the heat energy produced is lost to the surrounding environment as hot air through the chimney of the plant (stack). Determine how much water is required to run the plant, i.e., to cool...
A local coal fired 200 megawatt electrical generating plant has a thermal efficiency of 30% and...
A local coal fired 200 megawatt electrical generating plant has a thermal efficiency of 30% and a nuclear 150 megawatt electrical generating plant has a thermal efficiency of 25%. a. Calculate the waste heat emitted by each (in megawatts) b. If the cooling water used for the nuclear plant were required to only rise in temperature by 2o C after it absorbs the waste heat, how much water per hour would be required to cool the nuclear plant (in cubic...