Question

A closely wound coil has a radius of 4.0 cm, 50 turns, and a total resistance...

A closely wound coil has a radius of 4.0 cm, 50 turns, and a total resistance of 40 Ω. At what rate must a magnetic field perpendicular to the face of the coil change in order to produce Joule heating in the coil at a rate of 2.0 mW?

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A circular coil of radius 4.0 cm, resistance 0.30 Ω, and 100 turns is placed in...
A circular coil of radius 4.0 cm, resistance 0.30 Ω, and 100 turns is placed in a uniform magnetic field at an angle of 30° with the plane of the coil. The magnitude of the field changes with time according to ?(?)=20?^(−0.3?) (in Tesla, t is time in seconds). What is the value of the current induced in the coil at the time t = 2.0 s?
A closely wound, circular coil with radius 2.80 cmhas 800 turns of wire. "Closely Wound" means...
A closely wound, circular coil with radius 2.80 cmhas 800 turns of wire. "Closely Wound" means all of the wire loops can be approximated to be the same radius and at the same position. A) What must the current in the coil be if the magnetic field at the center of the coil is 0.0790 T? I= B) At what distance x from the center of the coil, on the axis of the coil, is the magnetic field half its...
A closely wound rectangular coil of 95.0 turns has dimensions of 22.0 cm by 49.0 cm....
A closely wound rectangular coil of 95.0 turns has dimensions of 22.0 cm by 49.0 cm. The plane of the coil is rotated from a position where it makes an angle of 35.0 ∘ with a magnetic field of 1.20 T to a position perpendicular to the field. The rotation takes 0.120 s. What is the average emf induced in the coil?
A closely wound, circular coil with a diameter of 4.50 cm has 630 turns and carries...
A closely wound, circular coil with a diameter of 4.50 cm has 630 turns and carries a current of 0.480 A . a)What is the magnitude of the magnetic field at the center of the coil? b)What is the magnitude of the magnetic field at a point on the axis of the coil a distance of 7.00 cm from its center?
A flat circular coil with 96 turns, a radius of 3.72 10-2 m, and a resistance...
A flat circular coil with 96 turns, a radius of 3.72 10-2 m, and a resistance of 0.432 Ω is exposed to an external magnetic field that is directed perpendicular to the plane of the coil. The magnitude of the external magnetic field is changing at a rate of ΔB/Δt = 0.837 T/s, thereby inducing a current in the coil. Find the magnitude of the magnetic field at the center of the coil that is produced by the induced current.
A flat coil of radius 4 cm has 30 turns and a resistance of 0.15 Ω,...
A flat coil of radius 4 cm has 30 turns and a resistance of 0.15 Ω, and is placed on a horizontal table. Initially, a uniform magnetic field of 0.75 T pointing upward (viewed from an observer above the table) passes through the coil. In 0.25 s, the magnitude of the magnetic field is changed to 0.35 T and the direction is completely reversed. (a) Determine the direction of the induced current in the coil. 2% Answer: ______________ Explain in...
A closely wound, circular coil with a diameter of 4.40 cmcm has 420 turns and carries...
A closely wound, circular coil with a diameter of 4.40 cmcm has 420 turns and carries a current of 0.540 AA . a)What is the magnitude of the magnetic field at the center of the coil? b)What is the magnitude of the magnetic field at a point on the axis of the coil a distance of 6.00 cmcm from its center?
20.1 A short circular coil with 15 turns has a radius of 7 cm. The coil...
20.1 A short circular coil with 15 turns has a radius of 7 cm. The coil is placed is a 2.5 T magnetic field. Find the flux through the coil for each case: a) the plane of the coil is perpendicular to the magnetic field b) the angle between the plane of the coil and the magnetic field is 35o.
A flat circular coil having 15 turns, each of a radius of 18.0 cm, is in...
A flat circular coil having 15 turns, each of a radius of 18.0 cm, is in a uniform and steady 0.130-T magnetic field. The coil has a resistance of 8.00 a) Find the total magnetic flux through one turn of the coil when the field is parallel to the axis of the coil. b) If the coil is rotated in 12.0 ms so its axis is perpendicular to the field, find the average induced voltage and the induced current in...
A coil 4 cm in radius, containing 500 turns, is placed in a uniform magnetic field...
A coil 4 cm in radius, containing 500 turns, is placed in a uniform magnetic field that varies with time according to B = 5.0 -0.1t + .012t^3 – 1.5e-0.3^t Tesla. The coil is connected to a 100 Ω resistor with its plane being perpendicular to the magnetic field. (i) What will be the emf generated in the coil as a function of time? (ii) What will be the current in the resistor at a time t = 5 sec...