A power station delivers 730 kW of power at 12,000 V to a factory through wires...

A power station delivers 730 kW of power at 12,000 V to a factory through wires with total resistance 5.0 Ω .How much less power is wasted if the electricity is delivered at 50,000 VV rather than 12,000 VV?

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A 546kW power station delivers power to a factory. The power is delivered through wires with...
A 546kW power station delivers power to a factory. The power is delivered through wires with a total (i.e. round-trip) resistance of 3.74Ohm. How much less power is wasted in the transmission wires if the electricity is delivered from the power station at 45000V rather than 12700V? (Hint: Consider the power plant as a battery delivering the voltage for the transmission line. How much current is flowing through the wire?)
Suppose a power plant produces 811 kW of power and is to send that power for...
Suppose a power plant produces 811 kW of power and is to send that power for many miles over a copper wire with a total resistance of 12.0 Ω. If the power is sent across the copper wires at 48.0 kV rms, how much current flows through the wires? If the power is sent across the copper wires at 48.0 kV rms, what is the power dissipated due to the resistance of the wires at this current? What percent of...
1. In an old house, the wires leading to a 120 V outlet have a total...
1. In an old house, the wires leading to a 120 V outlet have a total resistance of 0.45 Ω. When you plug in a hair dryer, it draws a 19 A current. - How much does the outlet voltage decrease due to the voltage drop across the wires? Express your answer with the appropriate units. - What is the power dissipated as heat in the wires? Express your answer with the appropriate units. 2. A typical American family uses...
A generator supplies 5.0 103 kW of power. The output potential difference is 4500 V before...
A generator supplies 5.0 103 kW of power. The output potential difference is 4500 V before it is stepped up to 510 kV. The electricity travels 400 mi (6.44 105 m) through a transmission line that has a resistance per unit length of 4.1 10-4 /m. (a) What percentage of the power is lost through transmission of the electrical energy along the line? % (b) What percentage of the power would be lost through transmission if the generator's output potential...
Suppose 89 kW is to be transmitted over two 0.150 Ω lines. Estimate how much power...
Suppose 89 kW is to be transmitted over two 0.150 Ω lines. Estimate how much power is saved if the voltage is stepped up from 180 V to 1800 V and then down again, rather than simply transmitting at 180 V . Assume the transformers are each 99%efficient. Express your answer using two significant figures.
14. A lightbulb is connected to a 120 V power source, forming a simple series circuit...
14. A lightbulb is connected to a 120 V power source, forming a simple series circuit with one load. The lightbulb has a resistance of 240 W and is left switched on for 6 hours. a) What is the current that flows through the lightbulb? How many electrons pass through the bulb in the 6 hour period?   What is the power dissipated in the lightbulb? If a power company charges 8 cents / kW×h for electricity, how much would it...
1- A 10.0-W resistor and a 20.0-W resistor are connected in series with a potentiometer and...
1- A 10.0-W resistor and a 20.0-W resistor are connected in series with a potentiometer and a 9.0-V battery. What should the potentiometer be set at for a total equivalent resistance of 50.0 W in this circuit? a. 10 Ω b. 20 Ω c. 30 Ω d. 50 Ω 2-Batteries are most often connected in a. series. b. parallel. c. both series and parallel. d. neither series nor parallel. (i think parallel) 3- A 9.0-V battery delivers a 1.3-A current...
Exploring Innovation in Action Power to the People – Lifeline Energy Trevor Baylis was quite a...
Exploring Innovation in Action Power to the People – Lifeline Energy Trevor Baylis was quite a swimmer in his youth, representing Britain at the age of 15. So it wasn’t entirely surprising that he ended up working for a swimming pool firm in Surrey before setting up his own company. He continued his swimming passion – working as a part-time TV stuntman doing underwater feats – but also followed an interest in inventing things. One of the projects he began...
Sign In INNOVATION Deep Change: How Operational Innovation Can Transform Your Company by Michael Hammer From...
Sign In INNOVATION Deep Change: How Operational Innovation Can Transform Your Company by Michael Hammer From the April 2004 Issue Save Share 8.95 In 1991, Progressive Insurance, an automobile insurer based in Mayfield Village, Ohio, had approximately $1.3 billion in sales. By 2002, that figure had grown to $9.5 billion. What fashionable strategies did Progressive employ to achieve sevenfold growth in just over a decade? Was it positioned in a high-growth industry? Hardly. Auto insurance is a mature, 100-year-old industry...
      MK Restaurant: Branding of Thai-Style Hotpot The restaurant industry is one of the most...
      MK Restaurant: Branding of Thai-Style Hotpot The restaurant industry is one of the most competitive in Thailand. With a large number of players ranging from restaurants in five-star hotels, global fast-food chains to small stalls along the streets and everything in between, the Thais are spoiled for choice. In addition, as the world becomes globalized, consumers are familiar with international dishes and would not hesitate to try new offerings from the other side of the globe. As a...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT