Question

A sample containing 12C, 16O, and an unknown isotope is analyzed in a mass spectrometer. As...

A sample containing 12C, 16O, and an unknown isotope is analyzed in a mass spectrometer. As in the figure, the ions move around a semicircle before striking a photographic plate. The 12C+ and 16O+ ions are separated by 3.850 cm on the plate, and the unknown isotope strikes the plate 1.130 cm from the 12C+ ions. What is the mass of the unknown element?

Homework Answers

Answer #1

The answer for above problem is explained below.

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A sample containing sulfur (atomic mass 32.0 u), manganese (55.0 u), and an unknown element is...
A sample containing sulfur (atomic mass 32.0 u), manganese (55.0 u), and an unknown element is analyzed in a mass spectrometer. As in the figure, the ions move around half a circle before striking a photographic plate. The sulfur and manganese ions are separated by 5.70 cm on the plate, and the unknown element strikes the plate 3.27 cm from the sulfur line. What is the mass of the unknown element?
A mass spectrometer is used to examine the isotopes of uranium. Ions in the beam emerge...
A mass spectrometer is used to examine the isotopes of uranium. Ions in the beam emerge from the velocity selector at a speed of 2.92 ✕ 105 m/s and enter a uniform magnetic field of 0.605 T directed perpendicularly to the velocity of the ions. What is the distance between the impact points formed on the photographic plate by singly charged ions of 235U and 238U? cm
You have a Bainbridge Mass Spectrometer with an electric field in the velocity selector of 1.20...
You have a Bainbridge Mass Spectrometer with an electric field in the velocity selector of 1.20 x 105 V/m and a magnetic field in both regions of 0.600 T. A stream of singly charged ions from a pure source (i.e.-all the atoms are the same type of element) move in a semicircular arc and strike the recording plate 1.46 m from the opening in the magnetic field chamber. Determine the mass of the ions. Given the fact that the mass...
Suppose the electric field between the electric plates in the mass spectrometer of (Figure 1) is...
Suppose the electric field between the electric plates in the mass spectrometer of (Figure 1) is 3.18×104V/m3.18×104V/m and the magnetic fields B=B′=0.77TB=B′=0.77T. The source contains carbon isotopes of mass numbers 12, 13, and 14 from a long-dead piece of a tree. (To estimate atomic masses, multiply by 1.67 ×10−27kg×10−27kg.) How far apart are the lines formed by the singly charged ions of mass numbers 12 and 13 on the photographic film? How far apart are the lines formed by the...
Suppose the electric field between the electric plates in the mass spectrometer of Figure 27-33 in...
Suppose the electric field between the electric plates in the mass spectrometer of Figure 27-33 in the textbook is 2.23×104 V/m and the magnetic fields are B=B′=0.38T. The source contains carbon isotopes of mass numbers 12, 13, and 14 from a long dead piece of a tree. (To estimate atomic masses, multiply by 1.66×10−27kg.) How far apart are the lines formed by the singly charged ions of each type on the photographic film ( d12−13, d13−14)? What if the ions...
Question 10 chap 4 A sample of 0.7960 g of an unknown compound containing barium ions...
Question 10 chap 4 A sample of 0.7960 g of an unknown compound containing barium ions (Ba2+) is dissolved in water and treated with an excess of Na2SO4. If the mass of the BaSO4 precipitate formed is 0.7651 g, what is the percent by mass of Ba in the original unknown compound?
A mass spectrometer is being used to separate common oxygen-16 from the much rarer oxygen-18, taken...
A mass spectrometer is being used to separate common oxygen-16 from the much rarer oxygen-18, taken from a sample of old glacial ice. (The relative abundance of these oxygen isotopes is related to climatic temperature at the time the ice was deposited.) The ratio of the masses of these two ions is 16 to 18, the mass of oxygen-16 is 2.66 ? 10?26 kg, and they are singly charged and travel at 2.60 ? 106 m/s in a 1.70 T...
A mass spectrometer is a device for separating particles of different masses from a mixture. For...
A mass spectrometer is a device for separating particles of different masses from a mixture. For example, the technology is used to investigate qualitative and quantitative changes within thousands of biologically active components such as proteins, lipids and metabolites. A mass spectrometer consists of three sections: The accelerator The velocity selector The magnetic chamber (1) Accelerator (acc): In the accelerator, there is only an uniform Electric field due to a potential difference Vacc across two vertical plates separated from a...
A mass spectrometer is a device for separating particles of different masses from a mixture. For...
A mass spectrometer is a device for separating particles of different masses from a mixture. For example, the technology is used to investigate qualitative and quantitative changes within thousands of biologically active components such as proteins, lipids and metabolites. A mass spectrometer consists of three sections: The accelerator The velocity selector The magnetic chamber (1) Accelerator (acc): In the accelerator, there is only an uniform Electric field due to a potential difference Vacc across two vertical plates separated from a...
Boron is the fifth element in the periodic table so it always has 5 protons. However,...
Boron is the fifth element in the periodic table so it always has 5 protons. However, different isotopes of bron have 3,5,6,7, or 8 neutrons in addition to the 5 protons to make up Boron-8, Boron-10, Boron 11, ect. As a research chemist for the Borax Soap Company you have been asked to use a mass spectrometer to determine the relative abundance of different isotopes of born in a sample. You decide to accelerate a beam of singly-ionized born ions....