Question

In general, the spatial resolution of a microscope is about equal to the wavelength of the...

In general, the spatial resolution of a microscope is about equal to the wavelength of the light being used t for the imaging. What is the estimated resolution of (a) an optical microscope using visible light and an electron microscope operating at (b) 500 V and (c) 50 kV?

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
The electron microscope can "see" smaller detail than an optical microscope because the wavelength of the...
The electron microscope can "see" smaller detail than an optical microscope because the wavelength of the electron can be made much shorter than visible light. Now consider the possibility of a proton microscope. By what potential difference (in volts) must A) a proton and B) an electron be accelerated to give a wavelength of 5x10-12m? Can you think of a reason why we have electron microscopes, but do not commonly have proton microscopes?
An electron beam in which electrons have a wavelength of 2.4pm is used in an electron...
An electron beam in which electrons have a wavelength of 2.4pm is used in an electron microscope with an aperture diameter of 2mm. (a) What is the angular resolution of this microscope, i.e. what is the minimum angle, in radians, that can be resolved? (b) Compare your answer in part (a) to the resolution achieved with visible light with wavelength of 550nm. (c) Compute the wavelength of photons with the same kinetic energy as the electrons and comment on why...
The resolving power of a microscope is proportional to the wavelength used. A resolution of 1.0  10-11...
The resolving power of a microscope is proportional to the wavelength used. A resolution of 1.0  10-11 m (0.010 nm) would be required in order to "see" an atom. (a) If electrons were used (electron microscope), what minimum kinetic energy would be required for the electrons? keV (classically) keV (relativistically) (b) If photons were used, what minimum photon energy would be needed to obtain 1.0  10-11 m resolution? keV
7. Resolving ‘power’ of an electron microscope versus optical (photon) microscope: If a resolution of 1.0...
7. Resolving ‘power’ of an electron microscope versus optical (photon) microscope: If a resolution of 1.0 x 10-11m (0.010nm) is required to ‘see’ an atom (a) If electrons are used (emicroscope), what minimum kinetic energy of the electrons is required? Use deBroglie’s Hypothesis and KE = p2 /2me and non-relativistic velocities: (b) If photons are used, what minimum KE (Eγ) is required to obtain 10-11m resolution?
The resolution of a light micrograph is limited by: A) wavelength of visible light B) quality...
The resolution of a light micrograph is limited by: A) wavelength of visible light B) quality of the microscopy C) magnification of the image D) width of an electron I put A but I wanted to double check
The magnification of a microscope depends inversely on the wavelength used to image a specimen. The...
The magnification of a microscope depends inversely on the wavelength used to image a specimen. The very best quality light microscopes typically have maximum magnifications of 1000 – 4000 times. Modern TEMs use electrons accelerated to energies of over 100 keV to observe specimens. Estimate the possible range of magnifications that can be achieved using a TEM by considering the following : a) What is a reasonable choice for the wavelength used in a light microscope ? b) What is...
In microscopy, Electron Microscopy imaging provides the capability of higher resolution imaging via the ultra-short wavelength...
In microscopy, Electron Microscopy imaging provides the capability of higher resolution imaging via the ultra-short wavelength of electrons compared to standard light radiation. Compare and contrast these other aspects of electron microscopy with standard light imaging. differences/similarities A) Lens system (mechanism and purpose) B) Sample preparation (fix, sectioning, mounting for imaging) C) Information that can be concluded from acquired images apart from structure/morphology (ex. Relative intensity data from fluorescence that informs regarding amount of tagged molecule presence)
A microscope has a 1 cm diameter objective lens with a focal length of 2.8 mm....
A microscope has a 1 cm diameter objective lens with a focal length of 2.8 mm. The microscope is using light with a wavelength of 550 nm a. What color is the light? b. What is the resolving power of the objective if used in air? c. What is the resolving power of the objective is used in oil with an index of refraction of 1.45? d. Would using a longer wavelength improve the resolution? Why or why not?
a) In an electron microscope, a potential difference of 20 kV is applied to accelerate the...
a) In an electron microscope, a potential difference of 20 kV is applied to accelerate the electrons. Determine the wavelength (in m) of the X-ray photons of equal energy as said electrons. If the wavelength of the X-rays is between 10 and 0.01 nm, what can you deduce about its calculation? b) An electron and a neutron have the same wavelength of de Broglie.
For electron microscope which accelerates electrons from rest through a potential difference of 10 kV. (a)...
For electron microscope which accelerates electrons from rest through a potential difference of 10 kV. (a) If the potential energy of an electron is taken to be 0 initially (at a 0 V plate), what potential energy does it have in Joules after accelerating to the 10 kV plate? (The electrons actually pass through a small hole in this plate before continuing on toward the sample). (b) What speed does the electron reach by the time it reaches the 10...