Question

A) A 1500-kg car is lifted to a height h by a hydraulic lift containing an...

A) A 1500-kg car is lifted to a height h by a hydraulic lift containing an incompressible fluid. A force of F_1 applied on a piston of area A_1 results in a larger force of F_2 on the plunger of larger area A_2. Suppose the piston has a radius of 0.0120 m and the plunger’s radius is 0.150 m. Calculate the height to which the car is lifted if the work done by the plunger is 200 J. (Assume that the weight of the plunger and fluid are negligible).

B) Calculate the distance the piston moves to lift the car to a height h.

C) A surgeon inserted a needle in the patient’s vein. The needle was connected to a top-open plastic bag filled with therapeutic fluid and lifted to a height h. Find h, which is just sufficient for the fluid to enter the vein, if the pressure gauge inside the vein was 5980 Pa. The therapeutic fluid density was adjusted to be the same as that of blood (see the lecture notes or textbook for the value).

D) At the next stage of the treatment procedure, the surgeon used a syringe to administer a drug fluid into the same vein as in part (c). The syringe was positioned at the same level as the vein. A force of 1.20 N was applied to the plunger of the cross-sectional area 0.81 cm2 connected to the needle of the inner radius 0.6 mm. What was pressure difference between the proximal and distal parts of the needle given that the proximal end opened into the vein? Use the same drug fluid density as in (c).

E) What volume of the drug fluid was injected into the vein in 2.5 s by the pressure difference calculated in (d)? [Hint: neglect the fluid speed in the syringe].

Homework Answers

Answer #1

Note : When no specific answer requirement is by you and if mutiple questions are there, we are supposed to provide the answer for main first question and it's subpart.

P.S : Please do give a thumbs up since we as an expert take pain and take our time out by typing answer in lucid language and putting best of our knowledge at your doorstep.
Thank you

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
(a) (2 marks) A 2000-kg car is lifted to a height h by a hydraulic lift...
(a) A 2000-kg car is lifted to a height h by a hydraulic lift containing an incompressible fluid. A force of F1 applied on a piston of area A1 results in a larger force of F2 on the plunger of larger area A2 . Suppose the piston has a radius of 0.0120 m and the plunger’s radius is 0.750 m. Calculate the height to which the car is lifted if the work done by the plunger is 200 J. (Assume...
A surgeon inserted a needle in the patient’s vein. The needle was connected to a top-open...
A surgeon inserted a needle in the patient’s vein. The needle was connected to a top-open plastic bag filled with therapeutic fluid and lifted to a height h. the pressure gauge inside the vein was 5980 Pa. The therapeutic fluid density was adjusted to be the same as that of blood (see the lecture notes or textbook for the value). (d) At the next stage of the treatment procedure, the surgeon used a syringe to administer a drug fluid into...
A surgeon inserted a needle in the patient’s vein. The needle was connected to a top-open...
A surgeon inserted a needle in the patient’s vein. The needle was connected to a top-open plastic bag filled with therapeutic fluid and lifted to a height h. Find h, which is just sufficient for the fluid to enter the vein, if the pressure gauge inside the vein was 5980 Pa. The therapeutic fluid density was adjusted to be the same as that of blood (see the lecture notes or textbook for the value). (d) At the next stage of...
(c) (4 marks) A surgeon inserted a needle in the patient’s vein. The needle was connected...
(c) A surgeon inserted a needle in the patient’s vein. The needle was connected to a top-open plastic bag filled with therapeutic fluid and lifted to a height h. Find h, which is just sufficient for the fluid to enter the vein, if the pressure gauge inside the vein was 5980 Pa. The therapeutic fluid density was adjusted to be the same as that of blood (see the lecture notes or textbook for the value). (d) At the next stage...
The hydraulic oil in a car lift has a density of 8.73 x 102 kg/m3. The...
The hydraulic oil in a car lift has a density of 8.73 x 102 kg/m3. The weight of the input piston is negligible. The radii of the input piston and output plunger are 8.10 x 10-3 m and 0.101 m, respectively. What input force F is needed to support the 24000-N combined weight of a car and the output plunger, when (a) the bottom surfaces of the piston and plunger are at the same level, and (b) the bottom surface...
The hydraulic oil in a car lift has a density of 8.04 x 102 kg/m3. The...
The hydraulic oil in a car lift has a density of 8.04 x 102 kg/m3. The weight of the input piston is negligible. The radii of the input piston and output plunger are 7.63 x 10-3 m and 0.158 m, respectively. What input force F is needed to support the 26400-N combined weight of a car and the output plunger, when (a) the bottom surfaces of the piston and plunger are at the same level, and (b) the bottom surface...
1.A hydraulic lift is lifting a car that weighs 14 kN. The area of the piston...
1.A hydraulic lift is lifting a car that weighs 14 kN. The area of the piston supporting the car is A, the area of the other piston is a, and the ratio A/a is 101.7. How far must the small piston be pushed down to raise the car a distance of 1.2 cm 2.The pressure inside a bottle of champagne is 4.8 atm higher than the air pressure outside. The neck of the bottle has an inner radius of 0.9...