Question

An MRI technician moves his hand from a region of very low (B=0) magnetic field strength...

An MRI technician moves his hand from a region of very low (B=0) magnetic field strength into an MRI scanner’s 3.50 T field with his fingers pointing in the direction of the field. He is wearing a ring whose diameter is 2. 0 cm and its resistance is 0.1 Ω.. Assume that it takes 0.40 s to move it into the field.

Calculate the change in the magnetic flux in the ring in the above scenario

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
An MRI technician moves his hand from a region of very low magnetic field strength into...
An MRI technician moves his hand from a region of very low magnetic field strength into an MRI scanner's 1.80 T field with his fingers pointing in the direction of the field. His wedding ring has a diameter of 2.21 cm, and it takes 0.360 s to move it into the field. (a) What average current is induced in the ring if its resistance is 0.0100 Ω? (Enter the magnitude in amperes.) ________ A (b) What average power is dissipated...
An MRI technician moves his hand from a region of very low magnetic field strength into...
An MRI technician moves his hand from a region of very low magnetic field strength into an MRI scanner's 1.50 T field with his fingers pointing in the direction of the field. His wedding ring has a diameter of 2.27 cm, and it takes 0.380 s to move it into the field. (a)What average current is induced in the ring if its resistance is 0.0100 Ω? (Enter the magnitude in amperes.) (b)What average power is dissipated (in W)? (c) What...
An MRI technician moves his hand from a region of very low magnetic field strength into...
An MRI technician moves his hand from a region of very low magnetic field strength into an MRI scanner's 1.70 T field with his fingers pointing in the direction of the field. His wedding ring has a diameter of 2.23 cm, and it takes 0.370 s to move it into the field. a.) What average current is induced in the ring if its resistance is 0.0100 ?? (Enter the magnitude in amperes.) b.) What average power is dissipated (in Watts)?...
An MRI technician moves his hand from a region of very low magnetic field strength into...
An MRI technician moves his hand from a region of very low magnetic field strength into an MRI scanner's 1.80 T field with his fingers pointing in the direction of the field. His wedding ring has a diameter of 2.29 cm, and it takes 0.330 s to move it into the field. a) What average current is induced in the ring if its resistance is 0.0100 Ω? (Enter the magnitude in amperes.) b) What average power is dissipated (in W)?...
1. An MRI technician moves his hand from a region of very low magnetic field strength...
1. An MRI technician moves his hand from a region of very low magnetic field strength into an MRI scanner’s 2.00 T field with his fingers pointing in the direction of the field. Find the average emf induced in his wedding ring in mV, given its diameter is 2.05 cm and assuming it takes 0.325 s to move it into the field. 2. An emf is induced by rotating a 1000 turn, 25 cm diameter coil in the Earth’s 5.00...
A TMS (transcranial magnetic stimulation) device creates very rapidly changing magnetic fields. The field near a...
A TMS (transcranial magnetic stimulation) device creates very rapidly changing magnetic fields. The field near a typical pulsed-field machine rises from 0 T to 2.5 T in 200 ?s. Suppose a technician holds his hand near the device so that the axis of his 1.8-cm-diameter wedding band is parallel to the field. What emf is induced in the ring as the field changes? If the band is made of a gold alloy with resistivity 6.2×10?8??m and has a cross-section area...
A TMS (transcranial magnetic stimulation) device creates very rapidly changing magnetic fields. The field near a...
A TMS (transcranial magnetic stimulation) device creates very rapidly changing magnetic fields. The field near a typical pulsed-field machine rises from 0 T to 2.5 T in 200 μs. Suppose a technician holds his hand near the device so that the axis of his 2.3-cm-diameter wedding band is parallel to the field. Part A- What emf is induced in the ring as the field changes? Express your answer with the appropriate units. Part B- If the band is made of...
The strength of the magnetic field within a solenoid is B = 2.1 × 10-2 T...
The strength of the magnetic field within a solenoid is B = 2.1 × 10-2 T (outside the solenoid B = 0). A smaller, single loop is placed in the solenoid parallel to the plane of each loop in the solenoid. The resistance of the solenoid is 5.9 W, the resistance of the loop is 0.27 W, the diameter of the solenoid is 0.09 m, and the diameter of the loop is 0.05 m. An emf of 12 V is...