Question

Data Sheet Table 1. Steel Bolt Specific Heat Data Bolt Ti (°C) Water Ti (°C) Water...

Data Sheet

Table 1. Steel Bolt Specific Heat Data

Bolt Ti (°C)

Water Ti (°C)

Water and Bolt Tf (°C)

Water ΔT = Tf - Ti

Bolt ΔT (°C)

Bolt Mass (kg)

Water Mass (kg)

Steel Bolt

72

20

23

3

72

.021

.15

Post-Lab Questions

A. The heat lost by the hot bolt is equal to the heat gained by the water in the calorimeter. Use the equations provided above and what you know about heat to solve for the specific heat (C) of the steel. Show your work.

B. What is the specific heat of steel from Table 1? Find the percent error for your calculated specific heat relative to this accepted value. Show your work.

C. What was the difference between your calculation and the actual specific heat of steel? How could you improve the experiment to reduce this error?

Homework Answers

Answer #1

Answer

Please cross check with the values given in table. Error is very big

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Lab Purpose: Determine the specific heat of an unknown metal by using the principle of thermal...
Lab Purpose: Determine the specific heat of an unknown metal by using the principle of thermal equilibrium. Question: Calculate the percent error between the experimental and theoretical values Aluminum Calorimeter Mass Tf Ti Specific Heat 52.5 25.3 22.4 900 Water Mass Tf Ti Specific Heat 146.5 25.3 22.4 4186 Metal Mass Tf Ti Specific Heat 65 25.3 100 394.5
Specific Heat Experiment: Calculate the percent error between the experimental and theoretical values Based on the...
Specific Heat Experiment: Calculate the percent error between the experimental and theoretical values Based on the expected values, what is the most likely metal? Procedure Metal A: Aluminum Calorimeter Mass Tf Ti Specific Heat 52.5 25.4 22.6 900 Water Mass Tf Ti Specific Heat 147.5 25.4 22.6 4186 Metal Mass Tf Ti Specific Heat 64.5         25.4 100 38.7 Procedure Metal B: Aluminum Calorimeter Mass Tf Ti Specific Heat 52.5 25.3 22.4 900 Water Mass Tf Ti Specific Heat 146.5 25.3...
SETUP In today’s lab we will measure specific heat using a calorimeter. A calorimeter consist of...
SETUP In today’s lab we will measure specific heat using a calorimeter. A calorimeter consist of a small metal cup inside a larger metal container, with a lid.  The cups are thermally separated from each other by means of air and a wooden ring, thus reducing the thermal conduction to a minimum. To keep track of how much water etc. we have, the whole calorimeter will be placed on a digital scale. Make sure to zero the scale before you place...
In a calorimetry experiment to determine the specific heat capacity of a metal block, the following...
In a calorimetry experiment to determine the specific heat capacity of a metal block, the following data was recorded: Quantity Mass of the metal block 0.50 kg Mass of empty calorimeter + Stirrer 0.06 kg Mass of calorimeter + stirrer + water 0.20 kg Mass of water 0.14 kg Initial Temperature of metal block 55.5 ⁰C Initial Temperature of water and calorimeter 22 ⁰C Final Temperature of block- water system 27.4 ⁰C Take the specific heat capacity of water to...
A student obtains the following data in a calorimetry experiment designed to measure the specific heat...
A student obtains the following data in a calorimetry experiment designed to measure the specific heat of aluminum. Initial temperature of water and calorimeter 70.4°C Mass of water 0.403 kg Mass of calorimeter 0.04 kg Specific heat of calorimeter 0.60 kJ/kg·°C Initial temperature of aluminum 27.1°C Mass of aluminum 0.196 kg Final temperature of mixture 66.4°C (a) Use these data to determine the specific heat of aluminum. J/kg · °C (b) Is your result within 15% of 900 J/kg ·...
Calculate the specific heat of a metal from the following experimental data. 75.0 ml cold water...
Calculate the specific heat of a metal from the following experimental data. 75.0 ml cold water is taken in a calorimeter. The initial temp of the water in the calorimeter is 21.2 degrees C. To the calorimeter containing cold water 29.458 g metal at 98.9 degrees C is added. The final temperature of the contents of the calorimeter is measured to be 29.5 degreesC. (Given: density of water= 1.00 g/ml, specific heat of water= 4.184 J. G. -1 degrees C...
The specific heat of mercury is 138 J/kg°C. Determine the latent heat of fusion of mercury...
The specific heat of mercury is 138 J/kg°C. Determine the latent heat of fusion of mercury using the following calorimeter data: 1.30 kg of solid Hg at its melting point of -39.0°C is placed in a 0.620 kg aluminum calorimeter with 0.400 kg of water at 12.80°C; the resulting equilibrium temperature is 2.91°C
CH6N2 (l) + 5 O2 (g) → + 2 N2 (g) + 2 CO2 (g) +...
CH6N2 (l) + 5 O2 (g) → + 2 N2 (g) + 2 CO2 (g) + 6 H2O (l) ΔH = -2600 kJ What is the Molar Mass H2O (2 decimal places Minimum)? In the last conversion factor what is the ratio of Heat ÷ moles H2O from the balanced equation (4 SF Minimum) - Is the sign + or -? ΔH (in kJ) - Is the sign + or -? The specific heat of ethanol is 2.46 J/goC. When...
1.Use the recorded data to fill in the blanks. Show work for calculations. Trial 1 Trial...
1.Use the recorded data to fill in the blanks. Show work for calculations. Trial 1 Trial 2 Trial 3 a Initial temperature of the cold water in the calorimeter (°C): 21.5 21.5 21.5 b Initial temperature of the hot water (°C): 60.0 60.0 60.0 c Mass of the hot water (assume density of 1.00 g/mL) (g) 50.0g 50.0g 50.0g d Mass of the cold water (assume density of 1.00 g/mL) (g) 50.0g 50.0g 50.0g e Final (maximum) temperature of water...
A student places a 72.0 gram sample of metal at an initial temperature of 100.˚C in...
A student places a 72.0 gram sample of metal at an initial temperature of 100.˚C in a coffee cup calorimeter that contains 40.0 grams of water at an initial temperature of 25.0 ˚C. After addition of the metal, the temperature of the water / metal mixture was monitored using a temperature probe. The highest temperature of the water / solid combination was found to be 35.0 ˚C. (The specific heat of water = 4.18 J / g ˚C ) Do...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT