Question

Insulation of steam pipes is an important aspect in industries to resist the heat loss from...

Insulation of steam pipes is an important aspect in industries to resist the heat loss from the steam pipe to the surrounding. In a typical steam pipe in an industry is made of steel( k=58w/mk) has inner diameter of 160mm and outside diameter of 170 mm. The saturated steam from a boiler flowing through the steam pipe is at 300C while the ambient air is at 50 C. The steel pipe has two layers of insulation the inner layer(k=0.17w/mc) is 30 mm thick and the outer layer (k=0.023W/mc) is 50mm thick and the inner and outer heat transfer coefficient are 30w/m^2C.find the rate of heat loss of steam pipe per unit length of the pipe

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Steam at an average temperature of ?∞= 400°C flows through a steel pipe. The inner and...
Steam at an average temperature of ?∞= 400°C flows through a steel pipe. The inner and outer radii of the pipe are r1 = 4 cm and r2 = 4.5 cm, respectively, and the outer surface of the pipe is insulated with a layer of 50 mm thick-calcium silicate of thermal conductivity of k = 0.5 W/m.K, and is maintained at 350 °C. If the convection heat transfer coefficient on the inner surface of the pipe is h = 65...
A pipe is transporting saturated steam at 1 bar (100°C) . The pipe has an inside...
A pipe is transporting saturated steam at 1 bar (100°C) . The pipe has an inside diameter of 100 mm with a 9 mm thick wall. The pipe is mild steel with a thermal conductivity of 80 W m-1 K-1. Covering the pipe is a 20 mm thick layer of polythene insulation with a thermal conductivity of 0.04 W m-1 K-1. The convective heat transfer coefficient of the steam is 513.4 W m-2 K-1. The convective heat transfer coefficient of...
A concentric tube heat exchanger is comprised of a stainless steel (ks = 40 W/mK) inner...
A concentric tube heat exchanger is comprised of a stainless steel (ks = 40 W/mK) inner pipe, NPS 2- nominal schedule 40 size (corresponding to an inner diameter of 52.5 mm and an outer diameter of 60.3 mm), and an outer stainless steel pipe of NPS 3-nominal schedule 40 (ID = 77.9 mm, OD = 88.9 mm). The heat exchanger has an effective length of 35 m. The inner pipe fluid is ammonia (?a = 0.3 · 10?6 m2/s, cpa...
A concentric tube heat exchanger is comprised of a stainless steel (ks = 40 W/mK) inner...
A concentric tube heat exchanger is comprised of a stainless steel (ks = 40 W/mK) inner pipe, NPS 2- nominal schedule 40 size (corresponding to an inner diameter of 52.5 mm and an outer diameter of 60.3 mm), and an outer stainless steel pipe of NPS 3-nominal schedule 40 (ID = 77.9 mm, OD = 88.9 mm). The heat exchanger has an effective length of 35 m. The inner pipe fluid is ammonia (va = 0.3 · 10-6m2/s, cpa =...
Doo not copy The context for the set of questions below is a gas-fired industrial boiler....
Doo not copy The context for the set of questions below is a gas-fired industrial boiler. Continuous emission monitoring requires that the flow of combustion gases be quantitated to allow for estimation of the total mass of each constituent emitted from the stack. Assume that the duct leading from the combustion chamber is exposed to outside air in a vertical run as it leaves the combustion chamber. Velocity of flow is to be measured within the outlet duct of the...
1. An oven chimney is made of brick with a heat transmission coefficient 1.1 W/mK 10...
1. An oven chimney is made of brick with a heat transmission coefficient 1.1 W/mK 10 cm thick. Since the shaft exterior radiation beam coefficient is 0.8 and the flue gas temperature is 350°C, the external ambient temperature is 25°C and the outer ambient heat transport coefficient is 20 W/m2K; a) Calculate the shaft exterior temperature. b) In order to reduce the risk of burn injury that may occur in the body, the shaft is asked to be below 55°Cve...