Question

Hot water in an open storage tank at 82.2°C is being pumped at a rate of...

Hot water in an open storage tank at 82.2°C is being pumped at a rate of 0.379 m3/min from the tank. The line from the storage tank to the pump suction is 6.1 m of 2-in schedule 40 steel pipe and it contains two elbows. The water discharge line after the pump is 61 m of 2-in pipe and contains two elbows. The water discharges to the atmosphere at a height of 6.1 m above the water level in the storage tank. a. Calculate all frictional losses Σ F. b. Make a MEB and calculate Ws of the pump in J/kg. c. What is the kW power of the pump if its efficiency is 75%?

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Water (at 25o C) from a lake is desired to be pumped over a 100 m...
Water (at 25o C) from a lake is desired to be pumped over a 100 m high hill to a pool of a house. A 300 m pipeline has three 45o elbows, two 90o elbows, two gate valves (one wide open and one half open). The dimensions of the pool are 8x6x2 m3 . The readily installed pump whose efficiency is 70% requires 6.4 kW power to fill the pool in 6 hours. The suction line is 5 m long...
Water is pumped by a motor-pump unit from a lake to a storage tank 17 m...
Water is pumped by a motor-pump unit from a lake to a storage tank 17 m above at a rate of 120 L/s. The storage tank is open to the atmosphere. The motor consumes 25 kW of electric power and the motor effciency is 95%. Disregarding any changes in kinetic energy of the water, determine (a) the overall effciency of the pump-motor unit, (b) the effciency of the pump and (c) the shaft power supplied by the motor to the...
Liquid water is pumped at 94 ° C from a storage tank at a rate of...
Liquid water is pumped at 94 ° C from a storage tank at a rate of 50 gal / min by means of a pump with a 2 HP motor and an efficiency of 80%. The water passes through a condenser delivering heat at a rate of 40,000 kJ / min, and is then deposited in a second storage tank that is 15 m above the first tank. Estimate the temperature of the water deposited in the second tank.
Water is being pumped at 20°C From an open tank through a 0.03561 m smooth pipe...
Water is being pumped at 20°C From an open tank through a 0.03561 m smooth pipe to a second tank at a higher level. The flow rate is 0.8 kg/s through 40 m of straight pipe with two threaded 90 regular elbows, one fully open globe valve and one half open gate valve. The supply tank maintains a liquid level of 2 m, and the water leaves the system at an elevation of 10 m above the floor. Calculate Reynolds...
Water (25 oC) is in an open tank at atmospheric pressure and the pump is 4.9...
Water (25 oC) is in an open tank at atmospheric pressure and the pump is 4.9 m below the open level. The friction head loss in the pipe is 1.5 m. Draw a diagram and calculate the Net Positive Suction Head.
Two large tanks with the same levels of water inside, one is open to the atmosphere...
Two large tanks with the same levels of water inside, one is open to the atmosphere while the other is closed and pressurized with an inside pressure of 65 k Pa gage . Water is to be pumped to the pressurized tank by a pump with 85% efficiency, placed in a stainless steel pipe connecting the two tanks at the lowest level. The pipe is 9cm in diameter, 100 m long and the volume flow rate is 0.025 m3/s find...
A farmer wants to pump water from a river to a very big open storage tank...
A farmer wants to pump water from a river to a very big open storage tank nearby using a 55-m long, 16-cm diameter plastic pipe with 5 threaded 90° regular bends, 5 threaded 45° regular bends, and one fully open gate valve. The water velocity near the river surface is 2.7 m/s and the pipe's inlet is placed in the river normal to the direction of water flow to take advantage of this water speed. The elevation difference between the...
Water at 20 0C is pumped at a rate of Q4= 0.042 m3/s from lower reservoir...
Water at 20 0C is pumped at a rate of Q4= 0.042 m3/s from lower reservoir to a higher reservoir with a height difference of H4=37 m as shown in the figure. The flow is assumed steady and incompressible. If irreversible losses in the pipe can be neglected, calculate the pump efficiency in percent, if the electric motor is rated at P4=29.1 kW and the motor efficiency can be assumed to be n4=87%. Answer:
Water at 20 0C is pumped at a rate of Q4= 0.022 m3/s from lower reservoir...
Water at 20 0C is pumped at a rate of Q4= 0.022 m3/s from lower reservoir to a higher reservoir with a height difference of H4=43 m as shown in the figure. The flow is assumed steady and incompressible. If irreversible losses in the pipe can be neglected, calculate the pump efficiency in percent, if the electric motor is rated at P4=29.4 kW and the motor efficiency can be assumed to be n4=82%.
City water will be cooled in a heat exchanger by sea water entering at 15°C. The...
City water will be cooled in a heat exchanger by sea water entering at 15°C. The outlet temperature of the sea water is 20°C. City water will be recirculated to reduce water consumption. The suction line of the pump has an inner diameter of 154 mm, is 22 m long, and has two 90° bends and a hinged check valve. The pipe from the pump to the heat exchanger has an inner diameter of 127 mm, is 140 m long,...