Question

Find the volume forr a system of saturated liquid-vapor mixture of water at 200 °C that...

Find the volume forr a system of saturated liquid-vapor mixture of water at 200 °C that contains 20 kg vapor AND 80 kg liquid

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
system, a rigid tank, contains mixture of saturated water vapor and saturated liquid at 90 oC....
system, a rigid tank, contains mixture of saturated water vapor and saturated liquid at 90 oC. Total mass is 1.5 kg. quality is 0,34. system is heated untill all liquid is converted into vapor. how much heat is transferred to the syste, show this process in P-v-diagram
Initially (state 1) a well-insulated rigid tank contains 20 kg of a saturated liquid-vapor mixture of...
Initially (state 1) a well-insulated rigid tank contains 20 kg of a saturated liquid-vapor mixture of water at 100 kPa and half of the mass is in the liquid phase. An electric resistance heater placed in the tank is now turned on and kept on until all the liquid in the tank is vaporized (state 2). Determine (a) the initial specific volume in m3/kg, (b) the final specific entropy in kJ/kg.K and (c) change of entropy in kJ/K.
Initially (state 1) a well-insulated rigid tank contains 20 kg of a saturated liquid-vapor mixture of...
Initially (state 1) a well-insulated rigid tank contains 20 kg of a saturated liquid-vapor mixture of water at 100 kPa and half of the mass is in the liquid phase. An electric resistance heater placed in the tank is now turned on and kept on until all the liquid in the tank is vaporized (state 2). Determine (a) the initial specific volume in m3/kg, (b) the final specific entropy in kJ/kg.K and (c) change of entropy in kJ/K.
A well-insulated rigid tank contains 6 kg of saturated liquid vapor mixture of water at 150...
A well-insulated rigid tank contains 6 kg of saturated liquid vapor mixture of water at 150 kPa. Initially, half of the mass is in liquid phase. An electric resistance heater placed in the tank is then turned on and kept on until all the liquid is vaporized. Determine the electrical work (Wel) in MJ
A 0.1-m3 rigid tank contains saturated liquid-vapor mixture of water, initially at 150 kPa and 52...
A 0.1-m3 rigid tank contains saturated liquid-vapor mixture of water, initially at 150 kPa and 52 percent quality. Heat is now transferred to the tank until the system becomes superheated vapor and the pressure reaches 300 kPa. Determine (a) the total mass of the mixture in the tank and (b) the amount of heat transferred.
A well-insulated rigid tank contains 5-kg of a saturated liquid-vapor mixture of water at 100 kPa....
A well-insulated rigid tank contains 5-kg of a saturated liquid-vapor mixture of water at 100 kPa. Initially, three-quarters of the mass is in the liquid phase. An electric heater with a power rating of 880 W is placed in the tank. Determine how long it will take to vaporize all the liquid in the tank. Show the process on a T-v diagram with respect to saturation lines.
Mixture of saturated liquid-vapor water enters a compressor with mass flow rate of 2 kg/s, velocity...
Mixture of saturated liquid-vapor water enters a compressor with mass flow rate of 2 kg/s, velocity of 150 m/s, pressure of 10 kpa and quality of 0.85. The substance leaves the compressor with the velocity of 40 m/s at 7 MPa and 450°C. The heat loss from the compressor is 200 kW. Neglecting the changes in potential energy, determine the compressor required power.
A mixture of 85% liquid water and 15% water vapor at 200 oC is feed to...
A mixture of 85% liquid water and 15% water vapor at 200 oC is feed to an adiabatic throttle. The outlet pressure is 3.0 bar. What is the fraction of vapor in the outlet?
A tank having a volume of 0.85 m^3 initially contains water as a two-phase liquid vapor...
A tank having a volume of 0.85 m^3 initially contains water as a two-phase liquid vapor mixture at 260 C and a quality of 0.7. Saturated water vapor at 260 C is slowly withdrawn through a pressure-regulating valve at the top of the tank as energy is transferred by heat to maintain the pressure constant in the tank. This continues until the tank is filled with saturated vapor at 260 C. Determine the amount of heat transfer in kJ. Neglect...
An air-water vapor mixture containing 20% ​​humidity at a dry thermometer temperature of 40 ° C...
An air-water vapor mixture containing 20% ​​humidity at a dry thermometer temperature of 40 ° C A tunnel is fed to the dryer by being heated to 70 ° C. Red pepper samples It is dried in adiabatic conditions. Leave the dryer system saturated For the mixing air-water vapor mixture, find the following. a) 10000 m3 of moist air at 40 ° C (air-water vapor mixture) warmth Required heat to increase to 70 ° C b) Air temperature at dryer...