Question

Air at 40°F db and 38°F wb is sensibly heated to 70°F db. What is the...

Air at 40°F db and 38°F wb is sensibly heated to 70°F db. What is the relative humidity (%) of the air at 70°F db? Draw a sketch of a psychrometric chart that demonstrates the process.

Homework Answers

Answer #1

Thank you. Please upvote it. ??

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Air at 45O​C (dry bulb) and 10% relative humidity is to be humidified adiabatically to 70%...
Air at 45O​C (dry bulb) and 10% relative humidity is to be humidified adiabatically to 70% relative humidity. (a) Use the psychrometric chart to estimate the adiabatic saturation temperature of the air. (b) Estimate the final temperature of the air and the rate at which water must be added to humidify 15 kg/min of the entering air. (c) What have you assumed in carrying out this calculation?
Air heated to 1 atm, 100 F and 40% relative humidity is transported over a 300...
Air heated to 1 atm, 100 F and 40% relative humidity is transported over a 300 foot length of circular sheet metal duct at a volumetric flow of 400 cfm. If the head loss equals 1 inch of water. Determine the diameter of the duct and the air velocity. You can assume that the inner surface of the duct has a relative roughness (ε / D ≈ 0).
Problem #2 Air at 80°F and 80% relative humidity are cooled to 51°F at a constant...
Problem #2 Air at 80°F and 80% relative humidity are cooled to 51°F at a constant pressure of 1 atm. Use the psychrometric chart to calculate the fraction of water that condenses, and the rate at which heat must be removed to deliver 1,000 ft3 /min of humid air at the final conditions.
(5 pts) 250 m3/s of air at 60% relative humidity is sent to a spray cooler...
(5 pts) 250 m3/s of air at 60% relative humidity is sent to a spray cooler and leaves saturated at 25 °C in an adiabatic process. What is the initial temperature of the air? (Use the psychrometric chart in your textbook).
An air-water vapor mixture containing 20% ​​humidity at a dry thermometer temperature of 40 ° C...
An air-water vapor mixture containing 20% ​​humidity at a dry thermometer temperature of 40 ° C A tunnel is fed to the dryer by being heated to 70 ° C. Red pepper samples It is dried in adiabatic conditions. Leave the dryer system saturated For the mixing air-water vapor mixture, find the following. a) 10000 m3 of moist air at 40 ° C (air-water vapor mixture) warmth Required heat to increase to 70 ° C b) Air temperature at dryer...
Atmosphric air at 40 F and 50% relative humidity enters the heating section of an airconditioning...
Atmosphric air at 40 F and 50% relative humidity enters the heating section of an airconditioning device at a volumetric flow rate of 100ft^3/min. Water vapor is added to the heated air to increase the relative humidity to 55%. The temperature after the heating section is 72F and the temperature at the exit is 74F. Using the appropriate fomulas: a) determine the rate of the heat transfer in Btu/min. b) determine the mass flow of water vapor in lbm/min.
A room is maintained at 70 DB and 60% RH. Heating air leaves the heating cooling...
A room is maintained at 70 DB and 60% RH. Heating air leaves the heating cooling coils at 85 DB and 50 RH. If 3000 cfm return air are mixed together, with 7000 cfm of heated air find the resulting dry and RH temperatures of the mixture.
An air conditioner is operating in a desert environment to cool air from 75?F with a...
An air conditioner is operating in a desert environment to cool air from 75?F with a relative humidity of 20% (?A = 0.2) to 55?F. Assuming your refrigeration cycle has a COPR of 3.5, what is the specific work required to do this? What is the percentage change in work required if the relative humidity at the inlet was increased to 80% (?B = 0.8)?
Air is heated as it flows through a constant diameter tube. The air enters the tube...
Air is heated as it flows through a constant diameter tube. The air enters the tube at 50 psia and 80 F with an average velocity of 10 ft/s at the entrance. The air leaves at 45 psia and 255 F. a) Sketch the control volume b) Determine the average velocity of the air (ft/s) at the exit c) If 23 lbm/min of air is to be heated, what diameter (in.) tube is required?
Air at 95°F, 1 atm, and 10% relative humidity enters an evaporative cooler operating at steady...
Air at 95°F, 1 atm, and 10% relative humidity enters an evaporative cooler operating at steady state. The volumetric flow rate of the incoming air is 1765 ft3/min. Liquid water at 68°F enters the cooler and fully evaporates. Moist air exits the cooler at 70°F, 1 atm. There is no significant heat transfer between the device and its surroundings and kinetic and potential energy effects can be neglected. a)Determine the mass flow rate of the dry air in lb(dry air)/min....