Preheating Air by Steam for Use in a Dryer. An air stream at 32.2 celsius is...

Preheating Air by Steam for Use in a Dryer. An air stream at 32.2 celsius is to be used in a dryer and is first preheated in a steam heater, where it is heated to 65.5 celsius. The air flow is 1000 kg mol/h. The steam enters the heater saturated at 148.9 celsius, is condensed and cooled, and leaves as a liquid at 137.8 celsius. Calculate the amount of steam used in kg/h.

Homework Answers

Answer #1

The detailed steps are given below

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Consider an air-cooled condenser in which a stream of R-134a enters at 12 bar and 60degC,...
Consider an air-cooled condenser in which a stream of R-134a enters at 12 bar and 60degC, and leaves as a saturated liquid at 12 bar, and air enters as a separate stream at 1 bar, 35degC and leaves at 1 bar, 45degC. The two streams do not mix but heat transfer from one stream to the other stream occurs at the rate of 6.94 kW. Determine (a) the mass flow rates for the R-134a and the air (kg/s), and (b)...
Water is the working fluid in a regenerative Rankine cycle with one closed feedwater heater. Steam...
Water is the working fluid in a regenerative Rankine cycle with one closed feedwater heater. Steam enters the turbine at 1400 lbf/in.2 and 1000°F and expands to 120 lbf/in.2, where some of the steam is extracted and diverted to the closed feedwater heater. The remaining steam expands through the second-stage turbine to the condenser pressure of 3.5 lbf/in.2 Each turbine stage and the pump have isentropic efficiencies of 85%. Flow through the condenser, closed feedwater heater, and steam generator is...
Saturated steam at 200 C, 1000 kg/h is used to boil toluene in a heat exchanger....
Saturated steam at 200 C, 1000 kg/h is used to boil toluene in a heat exchanger. The toluene enters at 50 C, 1 bar, 3500 kg/h and leaves as vapor at 1 bar. The steam condensate leaving is saturated water at 200 C. Calculate the exit toluene temperature.
An air-cooled steam condenser is operated with air in cross flow over a square, in-line array...
An air-cooled steam condenser is operated with air in cross flow over a square, in-line array of 400 tubes (NL=NT= 20), with an outside tube diameter of 20 mm and longitudinal and transverse pitches of SL= 60 mm and ST= 42 mm, respectively. Saturated steam at a pressure of 2.455 bars enters the tubes, and a uniform tube outer surface temperature of Ts= 390 K may be assumed to be maintained as condensation occurs within the tubes. (a) If the...
Question 4 Saturated steam at 227°C is used in a heat exchanger to preheat a reactor...
Question 4 Saturated steam at 227°C is used in a heat exchanger to preheat a reactor feed stream. (a) If the condensate (saturated liquid) is removed from the heat exchanger at 152°C and the flow rate is 1000 kg/h, how much heat (kJ) is transferred from the steam to heat up the reactor feed stream in one hour? (b) How much additional steam would be required if the condensate is removed at 227°C, instead of 152°C, for the same exit...
Saturated steam at 350 C is used to heat a countercurrent stream of methanol vapor from...
Saturated steam at 350 C is used to heat a countercurrent stream of methanol vapor from 70C to 300C in an adiabatic heat exchanger. The flow rate of methanol is 6000 L (STP) / min, and the steam condenses and leaves the exchanger as liquid water at 80C. a) Calculate the necessary flow of the incoming steam in m 3 / min. b) Calculate the heat flux transferred from water to methanol (kW).
saturated steam at 300 C is used to heat countercurrently flowing stream of methanol vapor from...
saturated steam at 300 C is used to heat countercurrently flowing stream of methanol vapor from 65C to 260 C in and adiabatic heat exchanger. The flow rate of the methanol is 5500 standard liters per minute, and the steam condenses and leaves the heat exchanger as liquid water at 90 C. A) calculate the required flow rate of the entering steam in m^3/min. B) Calculate the rate of heat transfer from the water to the methanol (kW).
A power plant operates on a regenerative vapor power cycle with one open feedwater heater. Steam...
A power plant operates on a regenerative vapor power cycle with one open feedwater heater. Steam enters the first turbine stage at 12 MPa, 560°C and expands to 1 MPa, where some of the steam is extracted and diverted to the open feedwater heater operating at 1 MPa. The remaining steam expands through the second turbine stage to the condenser pressure of 17 kPa. Saturated liquid exits the open feedwater heater at 1 MPa. The net power output for the...
Saturated steam at a gauge pressure of 3.00 bar is to be used to heat a...
Saturated steam at a gauge pressure of 3.00 bar is to be used to heat a stream of ethane. The ethane enters a heat exchanger at 16°C and 1.5 bar gauge pressure at a rate of 895 m3/min and is heated at constant pressure to 93°C. The steam condenses and leaves the exchanger as a liquid at 24.0°C. The specific enthalpy of ethane at the given pressure is 941 kJ/kg at 16°C and 1073 kJ/kg at 93°C.   You may take...
Saturated water vapor leaves a steam turbine at a flow rate of 1.47 kg/s and a...
Saturated water vapor leaves a steam turbine at a flow rate of 1.47 kg/s and a pressure of 0.51 bar. The vapor is to be completely condensed to saturated liquid in a shell-and-tube heat exchanger that uses city water as the cold fluid. The water enters the thin-walled tubes at 17oC and is to leave at 57.6 oC. Assuming an overall heat transfer coefficient of 2000 W/m2K, determine the required heat exchanger surface area and the water flow rate. cp,c...
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT