Question

A room has a relative humidity of 43% at 75 F = 23.9 C, and a...

A room has a relative humidity of 43% at 75 F = 23.9 C, and a pressure of 0.99 atm. What is the concentration of water in the air in ppm (by mol)?

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
Humid air at 75 °C, 1.1 bar and 30% relative humidity is fed at a rate...
Humid air at 75 °C, 1.1 bar and 30% relative humidity is fed at a rate of 1000 m3/h. Vapor pressure at 75 °C = 289 mm g. Determine the Molal Humidity Absolute humidity, Percentage humidity
Humid air at 75 °C, 1.1 bar and 30% relative humidity is fed at a rate...
Humid air at 75 °C, 1.1 bar and 30% relative humidity is fed at a rate of 1000 m3/h. Vapor pressure at 75 °C = 289 mm g. Determine the Molal Humidity Absolute humidity, Percentage humidity
Problem #2 Air at 80°F and 80% relative humidity are cooled to 51°F at a constant...
Problem #2 Air at 80°F and 80% relative humidity are cooled to 51°F at a constant pressure of 1 atm. Use the psychrometric chart to calculate the fraction of water that condenses, and the rate at which heat must be removed to deliver 1,000 ft3 /min of humid air at the final conditions.
Air at 50.0% relative humidity is cooled isobarically at 1 atm absolute from 90.0°C to 15.0°C....
Air at 50.0% relative humidity is cooled isobarically at 1 atm absolute from 90.0°C to 15.0°C. a. Estimate the dew point and the degrees of superheat of the air at 90.0°C. Dew point: °C Degrees of superheat: °C b. How much water condenses (mol) per cubic meter of feed gas? (See Example 6.3–2) mol c. Suppose a sample of the 90.0°C air is put in a closed variable-volume chamber containing a mirror and the pressure is raised at constant temperature...
The relative humidity of air equals the ratio of the partial pressure of water in the...
The relative humidity of air equals the ratio of the partial pressure of water in the air to the equilibrium vapor pressure of water at the same temperature times 100%. If the relative humidity of the air is 58% and its temperature is 68 oF , how many moles of water are present in a room measuring 12 ft x 10 ft x 8 ft? The vapor pressure of water at 68 oF is 17.54 torr. The answer is 20,...
Air at 95°F, 1 atm, and 10% relative humidity enters an evaporative cooler operating at steady...
Air at 95°F, 1 atm, and 10% relative humidity enters an evaporative cooler operating at steady state. The volumetric flow rate of the incoming air is 1765 ft3/min. Liquid water at 68°F enters the cooler and fully evaporates. Moist air exits the cooler at 70°F, 1 atm. There is no significant heat transfer between the device and its surroundings and kinetic and potential energy effects can be neglected. a)Determine the mass flow rate of the dry air in lb(dry air)/min....
On an uncomfortable summer day, the air is at 30.6°C (87°F) and 80% relative humidity. A...
On an uncomfortable summer day, the air is at 30.6°C (87°F) and 80% relative humidity. A laboratory air conditioner is to deliver 28.3 m^3/min of air at 12.8°C (55°F) in order to maintain the interior air at a comfortable temperature and humidity. Estimate the rate (in kg/min) at which water is condensed and the net tons of cooling required, where 1 ton of cooling = -12,000 BTU/h = -12,650 kJ/h.
A humid air stream enters a process at 35 C, 20 atm, and 50% relative humidity....
A humid air stream enters a process at 35 C, 20 atm, and 50% relative humidity. The oxygen flows at 900kmol/h. Determine the molar flow rate of water in the stream.
Air at 45O​C (dry bulb) and 10% relative humidity is to be humidified adiabatically to 70%...
Air at 45O​C (dry bulb) and 10% relative humidity is to be humidified adiabatically to 70% relative humidity. (a) Use the psychrometric chart to estimate the adiabatic saturation temperature of the air. (b) Estimate the final temperature of the air and the rate at which water must be added to humidify 15 kg/min of the entering air. (c) What have you assumed in carrying out this calculation?
Atmosphric air at 40 F and 50% relative humidity enters the heating section of an airconditioning...
Atmosphric air at 40 F and 50% relative humidity enters the heating section of an airconditioning device at a volumetric flow rate of 100ft^3/min. Water vapor is added to the heated air to increase the relative humidity to 55%. The temperature after the heating section is 72F and the temperature at the exit is 74F. Using the appropriate fomulas: a) determine the rate of the heat transfer in Btu/min. b) determine the mass flow of water vapor in lbm/min.
ADVERTISEMENT
Need Online Homework Help?

Get Answers For Free
Most questions answered within 1 hours.

Ask a Question
ADVERTISEMENT