Question

Wastewater (65 kg/s) needs to be cooled from 80 °C to 50 °C. Cooling water will...

Wastewater (65 kg/s) needs to be cooled from 80 °C to 50 °C. Cooling water will be used for cooling, with an inlet temperature of 25 °C and outlet temperature of 55 °C

Determine whether the exchanger is suitable for the duty, and estimate the pressure drop for each stream.

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
A milk is to be cooled down from 40 degree celcius at the flow rate of...
A milk is to be cooled down from 40 degree celcius at the flow rate of 150g/s to 15 degree celcius. a) Estimate the required cooling duty for this process. b) select the suitable cooling stream to be used for this process;justify your selection c) Select the suitable type of heat exchanger to be used for this process;justify your selection and the assumptions made d) Calculate the overall heat transfer coefficient for your selected heat exchanger with any assumptions made...
City water will be cooled in a heat exchanger by sea water entering at 15°C. The...
City water will be cooled in a heat exchanger by sea water entering at 15°C. The outlet temperature of the sea water is 20°C. City water will be recirculated to reduce water consumption. The suction line of the pump has an inner diameter of 154 mm, is 22 m long, and has two 90° bends and a hinged check valve. The pipe from the pump to the heat exchanger has an inner diameter of 127 mm, is 140 m long,...
a hot water ar 80°C is mixed with cold water at 20°C in a mixing chamber...
a hot water ar 80°C is mixed with cold water at 20°C in a mixing chamber operating under adiabotic conditions. Flow rate of the cold water is 15.0 kg/s. The outlet stream is warm water at 45°C and 100 kPa. Estimate the flow rate of the hot water.
A 0.4-L glass of water at 20°C is to be cooled with ice to 5°C. The...
A 0.4-L glass of water at 20°C is to be cooled with ice to 5°C. The density of water is 1 kg/L, and the specific heat of water at room temperature is c = 4.18 kJ/kg·°C. The specific heat of ice at about 0°C is c = 2.11 kJ/kg·°C. The melting temperature and the heat of fusion of ice at 1 atm are 0°C and 333.7 kJ/kg. A) Determine how much ice needs to be added to the water, in...
A natural draft-cooling tower is to remove 50 MW of waste heat from cooling water, which...
A natural draft-cooling tower is to remove 50 MW of waste heat from cooling water, which enters the tower at 42 °C and leaves at 27 °C. Atmospheric air enters the tower at standard atmospheric pressure with dry and wet bulb temperatures of 23 °C and 18 °C respectively (approximately 62% relative humidity), and leaves saturated at 37 °C. a) Sketch a fully labelled schematic diagram of the system identifying all the state points. Illustrate the process on a psychrometric...
1) 20 kg/min water at 20º C is mixed adiabatically with 40 kg/min water at 80...
1) 20 kg/min water at 20º C is mixed adiabatically with 40 kg/min water at 80 ºC. What is the outlet water temperature? Select one: a. 80 °C b. 60 °C c. 50 °C d. 70 °C 2) Steam at 0.8 MPa and 500 ºC is throttled over a well insulated valve to 0.6 MPa, what is the outlet temperature Select one: a. 450 ºC b. 500 ºC c. DOF>0 d. 400 ºC 3) Humid air at 70 C and...
A 1 to 2 baffled shell-and-tube type heat exchanger is used as an engine oil cooler....
A 1 to 2 baffled shell-and-tube type heat exchanger is used as an engine oil cooler. Cooling water flows through tubes at 25 °C at a rate of 8.16 kg/s and exits at 35 °C. The inlet and outlet temperatures of the engine oil are 65 and 55 °C, respectively. The heat exchanger has 12.25-in. I.D. shell, and 18 BWG and 0.75-in. O.D. tubes. A total of 160 tubes are laid out on a 15/16-in. triangular pitch. By assuming Ro...
A shell and-tube heat exchanger is required for the following service: Hot stream Cold Stream Aromatic...
A shell and-tube heat exchanger is required for the following service: Hot stream Cold Stream Aromatic Stream Cooling Water inlet Temperature (oC) 85 20 outlet Temperature (oC) 40 35 Mass Flowrate x heat Capacity (kW/oC) 85.2 Hot Stream cold stream (Cooling water) Heat Capacity (J/kg K) 2840 4193 Density (kg/m3) 750 999 Viscosity (cP) 0.34 1.016 Thermal conductivity (W/m.K) 0.19 0.594 Fouling Factor (m2.oC/W 0.00018 0.000176 ? The cooling water is allocated to the tube-side of the exchanger. ? It...
A horizontal shel-and-tube heat exchanger with two tube passes and one shell pass is being used...
A horizontal shel-and-tube heat exchanger with two tube passes and one shell pass is being used to heat 9 kg/s of 100% ethanol from 25 to 65 C at atmospheric pressure. The ethanol pasar through the inside of the tubes, and saturated steam at 115 C condenses an the shell of the tubes. The tubes are atell with an OD of 0.019 m and a BWG of 14. The exchanger contains a total of 100 tubes (50 tubes per pass)....
Liquid carbon dioxide at a flow rate of 100 000 kg/hr is to be heated from...
Liquid carbon dioxide at a flow rate of 100 000 kg/hr is to be heated from 0°C to 20°C in a 1-2 shell and tube heat exchanger. Water is available at a flow rate of 113 000 kg/hr and a temperature of 40°C. A 25-in. (635 mm)-ID 1-2 shell and tube exchanger having 3/4-in., 10 BWG tubes laid out on a 1-in. triangular pitch is available. The tubes are 2 m long and the exchanger contains three baffles. Determine expected...