Question

A soluble gas is absorbed into water using a packed tower. The equilibrium relationship may be...

A soluble gas is absorbed into water using a packed tower. The equilibrium relationship may be taken as y = 2x. The incoming vapor stream contains 1% of this soluble gas in air and 90% of the soluble gas must be removed from the air stream. Using a basis of 1 lb-mole/hr for the inlet vapor stream:

(a) Find the minimum water flowrate for this unit operation.

(b) Using a water flowrate 25% greater than the minimum, find the number of transfer units needed to meet specs. (solve this both analytically and graphically)

Homework Answers

Know the answer?
Your Answer:

Post as a guest

Your Name:

What's your source?

Earn Coins

Coins can be redeemed for fabulous gifts.

Not the answer you're looking for?
Ask your own homework help question
Similar Questions
1. Ammonia is being absorbed from nitrogen gas using water at 1 atm and 80° F....
1. Ammonia is being absorbed from nitrogen gas using water at 1 atm and 80° F. In the incoming N2, 45 kg/hr of ammonia are flowed into the column, and the gas is 2 mass% ammonia. Henry’s constant is 1.414. 99% of the incoming ammonia is absorbed in the water. a. Assuming L/V=2Lmin/V, how many trays are required for separation? Assuming L/V=4Lmin/V, how many trays are required for separation? b. If a tray spacing of 24" is to be used,...
1. Ammonia is being absorbed from nitrogen gas using water at 1 atm and 80° F....
1. Ammonia is being absorbed from nitrogen gas using water at 1 atm and 80° F. In the incoming N2, 45 kg/hr of ammonia are flowed into the column, and the gas is 2 mass% ammonia. Henry’s constant is 1.414. 99% of the incoming ammonia is absorbed in the water. a. Assuming L/V=2Lmin/V, how many trays are required for separation? b. Assuming L/V=4Lmin/V, how many trays are required for separation?
It is desired to absorb ammonia from air into water producing an outlet gas stream with...
It is desired to absorb ammonia from air into water producing an outlet gas stream with 0.5mol% ammonia. equilibrium data given as y=1.414x in mole fraction. The counter current column has three equilibrium stages. Entering gas stream has a total of 10 kgmole/hr and has 80% mil NH3. Inlet water stream contains 2% mil ammonia. Find required flow rate entering liquid stream and flow rate of all outlet stream.
A production facility heats various equipment using a network of heated air and water vapor lines....
A production facility heats various equipment using a network of heated air and water vapor lines. A boiler produces a 195.0 mol/hr stream consisting of 0.590 mol fraction of water and 0.410 mol fraction of air at 131.0°C and 5200.0 mmHg. The air and water vapor cool as the gases move away from the boiler, and steam traps collect and remove condensed water from the lines while the pressure remains constant. a) If a total of 65.6 mol/hr of condensed...